  1. Development of Technologies that Address the Complex Architecture of the Face During the Treatment of Severe Facial Burn Injury

    SBC: Applied Tissue Technologies LLC            Topic: DHP13016

    The overall goal of this project, in response to SBIR topic DHP12-016, is to refine and validate in an IACOC approved porcine study a novel easily deployed device to immediately treat severe facial burns in order to prevent infection and wound progression

    SBIR Phase II 2015 Department of DefenseDefense Health Agency
  2. A Universal Device for Performing Cricothyrotomies

    SBC: WOLF TECHNICAL SERVICES INC            Topic: DHP13015

    The purpose of this Phase II program is to develop an innovative, low cost, all-in-one surgical instrument for performing cricothyrotomies and managing airway trauma on the battlefield, with improvements aimed at ultimately reducing mortality rates associ

    SBIR Phase II 2015 Department of DefenseDefense Health Agency
  3. Ultra-High Precision Laser Isotope Monitor for I3CO2, CO180 and CO170

    SBC: AERODYNE RESEARCH INC            Topic: 831RC

    Greenhouse gas (GHG) emissions are primary drivers of global climate change. Hence there is a crucial need to quantify their sources and sinks. A powerful method to constrain source and sink strengths is the analysis of the relative proportions of isotopic variants of GHG’s in atmospheric samples like those collected globally by NOAA’s Cooperative Air Sampling Network. Measurements that are ca ...

    SBIR Phase II 2015 Department of CommerceNational Oceanic and Atmospheric Administration
  4. Multi-Purpose Above Surface/Below Surface Expendable Dropsondes (MASED)

    SBC: BOSTON ENGINEERING CORPORATION            Topic: 842W

    There are currently no inexpensive, expendable air-deployed monitoring systems (Dropsondes) that measure atmospheric data and oceanographic as a function of depth. These are important data in predicting the intensity and path of hurricanes. Boston Engineering proposes to provide NOAA with a solution to this challenge with the Multi-Purpose Above Surface/Below Surface Expendable Dropsonde (MASED) p ...

    SBIR Phase II 2015 Department of CommerceNational Oceanic and Atmospheric Administration
  5. A uMECS miniature blower for respiratory protection systems, Phase II

    SBC: Vibrant Composites Inc.            Topic: CBD14103

    Air management solutions capable of reducing heat and moisture burden are not suitable for integration in wearable respiratory protection systems due to excessive weight, volume, and power requirements of existing technologies. Vibrant Composites proposes applying its unique uMECS manufacturing technology towards development of an ultra-lightweight and power efficient miniature blower. Fundamental ...

    SBIR Phase II 2015 Department of DefenseOffice for Chemical and Biological Defense
  6. Application of a Wireless Finger-mounted Ultrasound Transducer and Imaging Platform

    SBC: SONIVATE MEDICAL, INC.            Topic: DHP14006

    We propose to add ultra-wide-band (UWB) wireless connectivity to a wearable, battery powered, finger-worn ultrasound probe and system (under development through a separate contract) capable of performing the FAST exam for use in the battlefield. UWB is particular suited to medical defense needs on the battlefield as the wireless transmission is undetectable, uses low power and has high bandwidth f ...

    SBIR Phase II 2015 Department of DefenseDefense Health Agency
  7. Technologies to Train Myoelectric Prosthesis Users for Optimal Functional Outcomes

    SBC: LIBERATING TECHNOLOGIES INC            Topic: DHP14011

    Myoelectric prostheses can help service members and civilians that have acquired or congenital limb loss restore function. Substantial training is required to allow individuals to take full advantage of their prosthesis. Unfortunately, currently available training tools are expensive, non-motivating, manufacturer specific and typically must remain in the clinic. One goal of this proposal is t ...

    SBIR Phase II 2015 Department of DefenseDefense Health Agency
  8. A system for augmenting training by Monitoring, Extracting, and Decoding Indicators of Cognitive workload (MEDIC)

    SBC: CHARLES RIVER ANALYTICS, INC.            Topic: DHP13002

    US military medical personnel may be deployed to a variety of operational environments where their success saving lives depends on their ability to act quickly and effectively, both as individuals and as teams. Therefore, effective training must go beyond individual skills to include interactions among team members, and how those interactions transfer to operational environments. Currently, traine ...

    SBIR Phase II 2015 Department of DefenseDefense Health Agency
  9. ACLAMATE: Automated Cognitive Load Assessment for Medical StAff Training and Evaluation

    SBC: APTIMA INC            Topic: DHP13002

    Although great strides have been made in the development of simulators for training technical and teamwork skills, substantially less progress has been made with regard to their assessment. Typically, skills and performance are assessed by an expert observer using a Likert-type rating scale with anchors ranging from low to high. However, such methods are extremely coarse, and often provide little ...

    SBIR Phase II 2015 Department of DefenseDefense Health Agency
  10. Portable Multi-Modal TBI (PMT) monitor

    SBC: VIVONICS INC            Topic: DHP13011

    Vivonics, Inc., together with clinical experts from the Mayo Clinic, are currently developing the Portable Multi-Modal Traumatic Brain Injury (PMT) monitor, a platform technology which will enable multiple neurological evaluations to be performed by a minimally trained person using a simple interface wired to a light-weight head-worn apparatus. During the Phase I period, the team successfully desi ...

    SBIR Phase II 2015 Department of DefenseDefense Health Agency