  1. TRANSMISSION HOLOGRAPHIC RELAY LENS FOR AIRCRAFT HEAD UP DISPLAY

    SBC: Apa Optics, Inc.            Topic: N/A

    THE OBJECTIVE OF THE PROPOSED EFFORT IS TO REDUCE THE SIZE, WEIGHT, AND COST OF THE RELAY OPTICS OF THE AIRCRAFT HEAD UP DISPLAY (HUD), BY REPLACING IT WITH TRANSMISSION HOLOGRAPHIC LENSES. HOLOGRAPHIC LENSES ARE VERY LIGHT AND CAN BE MANUFACTURED AT VERY LOW COSTS. APPLICATIONS OF HOLOGRAPHIC LENSES TO HUD WERE LIMITED IN THE PAST, DUE TO WIDE SPECTRAL BAND OF THE HUD - CATHODE RAY TUBE (CRT). HO ...

    SBIR Phase II 1987 Department of DefenseAir Force
  2. INTEGRATED OPTICS SCANNER FOR WAFER INTERCONNECT

    SBC: Apa Optics, Inc.            Topic: N/A

    N/A

    SBIR Phase I 1987 Department of DefenseAir Force
  3. SYNTHESIS OF HIGH MOLECULAR WEIGHT IRON CHELATORS

    SBC: Biomedical Frontiers, Inc.            Topic: N/A

    IN CHEMICAL AND BIOLOGICAL SYSTEMS, IRON IS BOTH UBIQUITOUS AND HIGHLY REACTIVE. IN A VARIETY OF CIRCUMSTANCES, THERE IS GREAT NEED FOR NEW APPROACHES TO THE REMOVAL OF IRON OR THE CONTROL OF ITS REACTIVITY. BIOMEDICAL FRONTIERS HAS PRODUCED A SERIES OF HIGH MOLECULAR WEIGHT IRON CHELATORS BASED ON DERIVATION OF A NUMBER OF SUBSTRATES WITH DEFER- OXAMINE B. THIS CHELATOR HAS AN EXTREMELY HIGH AFFI ...

    SBIR Phase II 1987 Department of Health and Human Services
  4. IMPROVED BIOCOMPATIBILITY OF INTRAOCULAR LENSES

    SBC: SURMODICS, INC.            Topic: N/A

    INTRAOCULAR LENS IMPLANTS HAVE RETURNED VISION TO MANY CATARACT PATIENTS. THESE IMPLANTS PROVIDE VISUAL ACUITY WITHOUT THE DISTORTION OR MAGNIFICATION THAT CAN RESULT FROMWEARING THICK-LENSED SPECTACLES OR CONTACT LENSES. HOWEVER,AS WITH ALL OTHER IMPLANTABLE DEVICES, THERE ARE PROBLEMS WITH THE INTERACTION OF THE SYNTHETIC LENSES WITH EYE TISSUES. INADVERTENT CONTACT BETWEEN THE LENS AND THE CORN ...

    SBIR Phase II 1987 Department of Health and Human Services
  5. RAPID ENZYME IMMUNOASSAY FOR CANNABINOIDS IN BLOOD

    SBC: SURMODICS, INC.            Topic: N/A

    SERIOUS ATTENTION HAS BEEN FOCUSED ON THE USE OF ILLICIT DRUGS BY AMERICANS IN ALL WALKS OF LIFE. ONE OF THE MOST ABUSED DRUGS FOR OVER TWO DECADES HAS BEEN MARIJUANA, WHICH IS NOW BEING USED BY BLUE- AND WHITE-COLLAR WORKERS, MILITARY PERSONNEL, PROFESSIONAL ATHLETES, AND HIGH SCHOOL STUDENTS. BECAUSE OF THIS, MANY EMPLOYERS (INCLUDING THE U.S. MILITARY) ARE BEGINNING TO DEMAND THAT WORKERS SUSPE ...

    SBIR Phase I 1987 Department of Health and Human Services
  6. ONE-STEP SEMIQUANTITATIVE DIPSTICK ENZYME IMMUNOASSAY

    SBC: SURMODICS, INC.            Topic: N/A

    BIO-METRIC SYSTEMS, INC. PROPOSES TO DEVELOP A SEMIQUANTITATIVE, NONLABORATORY ENZYME IMMUNOASSAY THAT IS EXPECTED TO BE SENSITIVE, RAPID, AND CONVENIENT TO USE. THIS IMMUNOASSAY WILL REQUIRE NO INSTRUMENTATION AND IS EXPECTED TO HAVE A SINGLE-STEP PROTOCOL: SIMPLY DIP THE APPARATUS IN THE SAMPLE, WAIT A PRESCRIBED TIME, AND OBSERVETHE RESULT. THE QUANTITY OF ANALYTE PRESENT IN THE TEST SAMPLE IS ...

    SBIR Phase I 1987 Department of Health and Human Services
  7. IMPROVED BIOCOMPATIBILITY OF PERITONEAL DIALYSIS TUBING

    SBC: SURMODICS, INC.            Topic: N/A

    N/A

    SBIR Phase I 1987 Department of Health and Human Services
  8. PROCEDURE TO PRODUCE HIGH-SPECIFIC-ACTIVITY (32)P-IP3

    SBC: SURMODICS, INC.            Topic: N/A

    N/A

    SBIR Phase I 1987 Department of Health and Human Services
  9. HIGH SPEED RANDOM ACCESS CAMERA

    SBC: Cyberoptics Corp            Topic: N/A

    THERE ARE MANY MILITARY AND COMMERCIAL APPLICATIONS WHERE VERY HIGH SPEED AND HIGH RESOLUTION SIGNAL PROCESSING, COMPUTING, IMAGE PROCESSING AND VISION SYSTEMS ARE DESIRABLE. CURRENT SYSTEMS ARE SEVERELY LIMITED BY DEVICES THAT REQUIRE RELATIVELY LONG TIMES TO GET INFORMATION INTO AND OUT OF THE SYSTEM. APPLICATIONS SUCH AS SURVEILLANCE, TRACKING, PROCESS MONITORING, QUALITY CONTROL AND MANY OTHER ...

    SBIR Phase I 1987 Department of DefenseAir Force
  10. A MULTICHANNEL WIDE-BAND BIOTELEMETRY SYSTEM

    SBC: DATA SCIENCES INTERNATIONAL, INC            Topic: N/A

    UNDER THIS PROPOSED EFFORT, THE FEASIBILITY OF A MULTICHANNEL FM TELEMETRY SYSTEM CAPABLE OF TELEMETERING WIDE-BAND PHYSIOLOGICAL DATA WILL BE STUDIED AND ALTERNATE DESIGNS WILL BE EVALUATED VIA THE CONSTRUCTIUON OF PROTOTYPES. THE SYSTEM WILL INCLUDE A TRANSMITTER CAPABLE OF TELEMETERING SIGNALS FROM COMMONLY USED ELECTRODES AS THE MAJOR FOCUS ON THIS EFFORT, WHILE INTEGRATING COMMERCIALLY AVAILA ...

    SBIR Phase II 1987 Department of Health and Human Services