  1. Quantum Cascade Laser Monitor for N0, N02 and 03

    SBC: AERODYNE RESEARCH INC            Topic: N/A

    This project will design and deliver a high accuracy monitor for the photo-chemically coupled pollutants nitric oxide, nitrogen dioxide and ozone using infrared absorption spectroscopy with quantum cascade (QC) lasers. The target molecules are monitored at air quality stations worldwide using instruments which require frequent calibration and are subject to significant chemical interferences (in t ...

    SBIR Phase II 2003 Department of CommerceNational Institute of Standards and Technology
  2. Robust MEMS Viscosity Meter for Condition-based Maintenance

    SBC: BOSTON MICROSYSTEMS INC            Topic: N/A

    In this NIST SBIR program Boston MicroSystems develops MEMS-based fluid viscosity-density sensors which can be installed in refrigerant system compressors to monitor, in real time, refrigerant system health. Such sensors will provide early detection of water contamination, lubricant degradation and other problems which can lead to catastrophic refrigerant system failure if left uncorrected. Such s ...

    SBIR Phase II 2003 Department of CommerceNational Institute of Standards and Technology
  3. Improved Manufacturing Processes for Circular Array Detectors

    SBC: Detector Technology, Inc.            Topic: N/A

    The goal of phase 1 was to create a channel electron multiplier that could be used in an array for configuration in the synchrotron beam application. In order to have little variance in first strike statistics contamination needed to be eliminated from the surface. This was accomplished with phase 1 research. During Phase 2 the primary objective is to manufacture a circular array of multipliers th ...

    SBIR Phase II 2003 Department of CommerceNational Institute of Standards and Technology
  4. Selective Speaker Interface to Support Smart Space Accessible Computing

    SBC: Intelligent Automation, Inc.            Topic: N/A

    The Smart Flow system developed by NIST provides a platform to develop standards that promote the interoperability of devices produced by different manufacturers. The NIST system can acquire and process multiple sensor data such as voice and image in real-time. Many applications such as speaker verification, head trackers, etc. can be implemented under the framework. In Phase 1, we have demonstrat ...

    SBIR Phase II 2003 Department of CommerceNational Institute of Standards and Technology
  5. Advanced Tools for Process Specification Language

    SBC: KNOWLEDGE BASED SYSTEMS INC            Topic: N/A

    This project will (i) extend and harden the PSL Editor and the Ontology-Driven XSLT Generator (ODXG) tools and (ii) extend the process description syntax (PDS) derived from the PSL for both KIF and XML/RDF formats. In addition, we will extend the PSL metatheoretical framework to support the PDS and the PSL tools by providing PSL extensions to support calendars and activity specialization, and by d ...

    SBIR Phase II 2003 Department of CommerceNational Institute of Standards and Technology
  6. Surface Selective Chiral Detection: A New Metrology Technique

    SBC: VESCENT PHOTONICS LLC            Topic: N/A

    The near chiral purity of the biosphere leads to a vast array of chiro-specific physiological responses. This chiro-specificity, in turn, gives rise to the need for the manufacturing of enantiomerically pure chiral chemicals, such as pesticides, pharmaceuticals, food additives, pigments, etc. Critical to the efficacy of both chiro-specific biology and chiro-synthesis/separation are the interfacial ...

    SBIR Phase II 2003 Department of CommerceNational Institute of Standards and Technology
  7. Compact, Turnable Diode Laser for Water-Vapor Spectroscopy

    SBC: VESCENT PHOTONICS LLC            Topic: N/A

    We will develop a compact external cavity stabilization system, which will employ independent electro-optic control over the optical path length of the cavity and a wavelength-selective element. The system should be able to cover a 30 nm range and give mode-hop-free tuning over 20 nm intervals. The design of the feedback system will be compatible with any commercially available laser diode from 63 ...

    SBIR Phase II 2003 Department of CommerceNational Institute of Standards and Technology
  8. Development of the Smart Environmental Monitoring System (SEMS)

    SBC: WILLIAMSRDM, INC.            Topic: N/A

    Firefighters have expressed the need for both increased accuracy in fire detection systems and greater access to environmental information in the event of a fire. To accomplish both tasks, Williams-Pyro, Inc. proposes to develop the Smart Environmental Monitoring System (SEMS). This system comprises both an advanced fire detection system and the networking capability necessary to provide real-time ...

    SBIR Phase II 2003 Department of CommerceNational Institute of Standards and Technology