You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. A Blubber- or Dorsal Fin-Piercing Tag Attachment System for Remotely-Deployed Cetacean Tags

    SBC: American Benchmark Machine Works            Topic: 824

    TECHNICAL ABSTRACT: Animal-borne electronic instruments (tags) are critical tools for monitoring the behavior and ecology of cetaceans, providing data needed for managing their populations and mitigating the threats they face. Although remote-deployment of tags onto cetaceans that cannot be captured has provided valuable data, attachment durations have been frustratingly short and variable. Our Ph ...

    SBIR Phase I 2018 Department of CommerceNational Oceanic and Atmospheric Administration
  2. A Blubber or Dorsal Fin Piercing Tag Attachment System for Remotely-Deployed Cetacean Tags

    SBC: American Benchmark Machine Works            Topic: 824

    Animal-borne electronic instruments (tags) are critical tools for monitoring the behavior and ecology of cetaceans, providing data needed for managing their populations and mitigating the threats they face. Although remote-deployment of tags onto cetaceans that cannot be captured has provided valuable data, attachment durations have been frustratingly short and variable. Our Phase II goal is to de ...

    SBIR Phase II 2019 Department of CommerceNational Oceanic and Atmospheric Administration
  3. A Broadband and Compact Dual Comb Spectrometer for Precise Field Detection of Trace Elements and Chemicals

    SBC: OPTICSLAH, LLC            Topic: DTRA20B003

    There is a growing need to accurately characterize nuclear materials not only for nuclear safeguards and nonproliferation treaty verification but also for forensics and provenance. Presently, nuclear material identification requires samples to be collected and sent to laboratories for analysis using large and expensive equipment, such as inductively coupled plasma mass spectrometers (ICP-MS) or se ...

    STTR Phase I 2021 Department of DefenseDefense Threat Reduction Agency
  4. A Broadband and Compact Dual Comb Spectrometer for Precise Field Detection of Trace Elements and Chemicals

    SBC: OPTICSLAH, LLC            Topic: DTRA20B003

    There is a growing need to accurately characterize nuclear materials not only for nuclear safeguards and nonproliferation treaty verification but also for forensics and provenance. At present, nuclear material identification requires samples to be collected and sent to laboratories for analysis using large and expensive equipment, such as inductively coupled plasma mass spectrometers (ICP-MS) or s ...

    STTR Phase II 2023 Department of DefenseDefense Threat Reduction Agency
  5. A Broadly Tunable Ultrashort Pulse IR OPO Pumped by a Mode-Locked

    SBC: SCIENCE & ENGINEERING ASSOC., INC.            Topic: N/A

    We propose to develop an innovative, compact ultrafast high brightness laser source, broadly tunable in the infrared for vibrationally-resolved infrared microscopy and other applications. By passive Kerr lens mode-locking of a novel diode-pumped tunable Cr:LiSAF laser, 100fs pulses will be generated at 100 MHZ repetition rate with an average power of 1W. An optical parametric oscillator (OPO) pump ...

    SBIR Phase I 1997 Department of Commerce
  6. Absolute Distance Interferometer for Manufacturing Metrology Applications

    SBC: Bridger Photonics, Inc.            Topic: 90101

    Bridger Photonics, Inc. will develop an absolute length metrology sensor that will simultaneously provide >1,000 measurements per second, 0.5 m maximum measurement distance. Bridger’s solution is will fill a gap in precision measurement technology for applications that require rapid monitoring of macroscopic distances such as positioning and calibration of surface metrology systems (CMM, AFM, SE ...

    SBIR Phase I 2016 Department of CommerceNational Institute of Standards and Technology
  7. Absolute Distance Interferometer for Manufacturing Metrology Applications

    SBC: Bridger Photonics, Inc.            Topic: NA

    Bridger Photonics, Inc. proposes to develop an absolute length metrology sensor that will simultaneously provide >1,000 measurements per second, 0.5 m maximum measurement distance. Bridger’s solution is will fill a gap in precision measurement technology for applications that require rapid monitoring of macroscopic distances such as positioning and calibration of surface metrology systems (CMM, ...

    SBIR Phase II 2017 Department of CommerceNational Institute of Standards and Technology
  8. A Calorimeter for the Nondestructive Assay of Tritium-Contaminated Samples

    SBC: Science Research Laboratory, Inc            Topic: N/A

    Tritium is handled routinely at laboratories in the United States, Canada, Japan, and Europe. There are several applications for nondestructive assay of solid tritium-contaminated samples including environmental clean-up, routine assay of tritium handling equipment, assay of fuel elements used by fusion reactors including the proposed ITER reactor, and routine monitoring of fission reactor core m ...

    SBIR Phase II 1996 Department of Commerce
  9. A Calorimeter for the Nondestructive Assay of Tritium-Contaminated Samples

    SBC: Science Research Laboratory, Inc            Topic: N/A

    N/A

    SBIR Phase I 1995 Department of Commerce
  10. AC Amplifier and System for Nanopore Based DNA Sequencing

    SBC: ELECTRONIC BIOSCIENCES, INC.            Topic: N/A

    In order to realize robust, inexpensive and routine DNA sequencing for medical, forensic, security and defense applications, new approaches must be pursued. One approach is the rapid readout of individual nucleotides as a single strand of DNA is drawn through a nanometer scale aperture. Although progress has been made with nanopore sequencing, some fundamental instrumental and system problems have ...

    SBIR Phase I 2008 Department of CommerceNational Institute of Standards and Technology
US Flag An Official Website of the United States Government