  1. Handheld IR Raman Spectroscopy for Rapid Chemical Identification

    SBC: Aerius Photonics, LLC.            Topic: CBD08102

    In Phase I, Aerius Photonics demonstrated Raman spectroscopy at 785 nm, 980 nm, and 1064 nm, with only 1064 nm-based excitation showing a reduction in fluorescence. In addition, Aerius Photonics and partner Ahura Scientific, demonstrated a breadboard version of an InGaAs-based Raman spectrometer to assess any engineering challenges. By the end of a Phase III, Aerius proposes to develop a handheld ...

    SBIR Phase II 2010 Department of DefenseOffice for Chemical and Biological Defense
  2. Low Cost LWIR Interferometric HSI System

    SBC: SPECTRUM PHOTONICS INC            Topic: CBD09108

    Due to the potential detection benefits offered by hyperspectral imaging spectroscopy, this is an area of great interest in terms of early detection of plume threats. The major constraint is in costs of components. Under this SBIR, our team will investigate innovative advances in the integration of uncooled microbolometer technologies to determine the potential for reducing detector cost and com ...

    SBIR Phase II 2010 Department of DefenseOffice for Chemical and Biological Defense
  3. Durable Anti-fog Coatings for Contoured Plastic Substrates Using Nanoparticles with Tunable Size and Surface Chemistry

    SBC: INNOSENSE CORPORATION            Topic: CBD09101

    Currently fielded respiratory protective systems in the Joint Services General Purpose Mask (JSGPM) program degrade in visual performance capability in extreme hot and cold environments. Optical and mechanical properties of existing anti-fog coatings also diminish when subjected to cleaning/sanitization operations. To address these needs, InnoSense LLC (ISL), in Phase I, has combined nanomaterials ...

    SBIR Phase II 2010 Department of DefenseOffice for Chemical and Biological Defense
  4. An Enhanced Quarter-Sized Optical NEMS Based Methyl Salicylate Sensor System (MS3)

    SBC: IMAGINATIVE TECHNOLOGIES, LLC            Topic: CBD09103

    Building on our successful Phase I work our Phase II objectives are to complete development and integration of our two proposed sensors into an unprecedented self-confirming MeS detection system further refining our ability to meet key requirements identified in Phase I. More specifically, we will develop a NEMS based MeS sensor system complete with a telemetry system and/or a remote logging, data ...

    SBIR Phase II 2010 Department of DefenseOffice for Chemical and Biological Defense
  5. Dielectrophoretic Microfluidic Protein Analysis System

    SBC: Physical Optics Corporation            Topic: CBD09104

    To address the U.S. Army CBD need for a low-cost, universal, robust, and fieldable device for rapid, reproducible identification of protein variants from biological samples with high throughput, Physical Optics Corporation (POC) proposes to develop a new Dielectrophoretic Microfluidic Protein Analysis (DiMiPA) system based on an electrodeless dielectrophoresis-based, continuous-flow protein separa ...

    SBIR Phase II 2010 Department of DefenseOffice for Chemical and Biological Defense
  6. Integrated Automated Pre-concentrator Inlet for Mass Spectrometer

    SBC: 1st Detect Corp            Topic: CBD09106

    This proposal describes a project to develop a pre-concentrator inlet system for a mass spectrometer. The pre-concentrator utilizes a heated mesh design that is coated with a variety of sorbent materials to provide high pre-concentration with adversely affecting the analysis time. An innovative method of evacuating the pre-concentrator chamber provides an additional gain in pre-concentration of 2 ...

    SBIR Phase II 2010 Department of DefenseOffice for Chemical and Biological Defense
  7. Computer-Assisted Strain Construction And Development Engineering (CASCADE)

    SBC: GENOMATICA, INC.            Topic: CBD06107

    The recent advances of modern high-throughput genomic technologies have resulted in a large number of fully sequenced microbial organisms. The construction of these comprehensive metabolic models serves many purposes including encapsulating all the data and allowing for in silco experiments to be performed that can drive experimental work and aid in strain development and optimization. The creatio ...

    SBIR Phase II 2007 Department of DefenseOffice for Chemical and Biological Defense
  8. Handheld Instrument for Nerve Agent Detection

    SBC: KUMETRIX, INC.            Topic: CBD06104

    Rapid detection and identification of chemical warfare nerve agents (CWNAs) are critical to the screening and subsequent treatment of exposed warfighters. Inhibition of cholinesterase activity is insufficient as a marker of exposure to CWNAs, in that it can give misleading results and does not distinguish CWNAs from commonly employed pesticides. This proposal presents a revolutionary field-porta ...

    SBIR Phase II 2007 Department of DefenseOffice for Chemical and Biological Defense
  9. Reagentless and Realtime Detection of Airborne Microorganisms

    SBC: LYNNTECH INC.            Topic: CBD06102

    Biological weapons are among the most serious threats facing the United States defense forces, today. Currently available bioaerosol sampling systems and cassettes require both sample preparation and a well equipped laboratory for analysis. Other detection methods rely on fragile bio-molecules for recognition of the target analyte. These systems are not suitable for onsite analysis. Infrared spec ...

    SBIR Phase II 2007 Department of DefenseOffice for Chemical and Biological Defense
  10. Self-Detoxifying, Disposable Protective Garments

    SBC: LYNNTECH INC.            Topic: CBD06108

    While zero-based tolerance protective clothing is suitable for first responders, it provides an unnecessary level of protection for first receivers who are exposed to a considerably reduced threat. The use of zero-based tolerance garments by first receivers is particularly problematic since they often work in the same garments for an extended period of time. Consequently, the unique needs of fir ...

    SBIR Phase II 2007 Department of DefenseOffice for Chemical and Biological Defense