You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. ADAPT-MP: Auto-Diagnostic Adaptive Precision Trainer for Myoelectric Prosthesis users

    SBC: Design Interactive, Inc.            Topic: DHP14011

    More than 1,500 Americans have lost a limb due to traumatic injury in combat in recent years.Upper limb loss can be treated with myoelectric prostheses, but such devices require intensive training to effectively operate. The need to concentrate and continuously react during training often takes amputees many months, with the result that many patients abandon use of the prosthesis. In the Phase I e ...

    SBIR Phase II 2015 Department of DefenseDefense Health Agency
  2. Humeral Head Intraosseous Training System

    SBC: SIMETRI, INC.            Topic: DHP13001

    Phase I research culminated in the delivery of a prototype single-arm humeral head HHIO PTT which was well received by users. The prototype trainer development focused on providing an accurate simulation of the humeral head IO procedure, and was shown through usability testing to have been successful. Follow-on research is now called for to develop this proven technology into a commercially viable ...

    SBIR Phase II 2015 Department of DefenseDefense Health Agency
  3. Digital SQUID Array for Portable Low-Field MRI System for Combat Diagnostics

    SBC: HYPRES INC            Topic: OSD11H18

    Recent research has shown that Superconducting Quantum Interference Devices (SQUIDs) may be used to measure the very weak magnetic signals in Magnetic Resonance Imaging (MRI) at ultra-low magnetic fields in the milli-tesla range or below. However, the signal-to-noise ratio (SNR) is quite low, requiring very long averaging times to obtain reasonable spatial resolution. Under the Phase I project, we ...

    SBIR Phase II 2013 Department of DefenseDefense Health Agency
  4. Novel Trap for Ticks and Fleas Incorporating a CO2 Generator

    SBC: TDA RESEARCH, INC.            Topic: DHP13007

    Military personnel must be protected from diseases transmitted by ticks and fleas, including Lyme disease. Effective surveillance of tick and flea vectors is vital to determine the population present, whether they are carrying disease, and whether control campaigns are working. Unfortunately, current surveillance tools are ineffective. In Phase I TDA designed, prototyped, and tested a novel ti ...

    SBIR Phase II 2015 Department of DefenseDefense Health Agency
  5. Remote Anger and Stress Management (M-SAT)

    SBC: Design Interactive, Inc.            Topic: OSD11H13

    Concern has been raised over the prevalence of behavioral health disorders in military personnel returning from deployment to the Middle East. While not appearing as an overt physical injury, disruptions of a psychological nature are often as debilitating, and there is an increasing need for support tools. Such tools should allow for standardized tracking, monitoring, and mitigation of anger and ...

    SBIR Phase II 2013 Department of DefenseDefense Health Agency
  6. Return on Investment Tool for Effective Medical Training (RITE-MT)

    SBC: Design Interactive, Inc.            Topic: OSD11H19

    The Return on Investment Tool for Effective Medical Training (RITE-MT) tool aims to substantially improve the decision making process of training system requirements and acquisition professionals by objectively quantifying training system Return On Training Investment (ROTI) based on lifecycle cost, schedule and performance impacts. RITE-MT uses a training needs-based approach to ROTI which incorp ...

    SBIR Phase II 2013 Department of DefenseDefense Health Agency
  7. Serious Game for Continuity of Care Training

    SBC: VCOM3D INC            Topic: OSD10H08

    For this Phase II SBIR project, Vcom3D proposes a Serious Game for Continuity of Care that trains combat physicians in making critical medical decisions when faced with a multiple-casualty, multi-trauma incident. The Serious Game for Continuity of Care will provide a fast-paced learning environment that will require the selective attention to numerous, competing visual and aural cues and delegatio ...

    SBIR Phase II 2013 Department of DefenseDefense Health Agency
  8. SynDaver Synthetic Human Phase Two

    SBC: SYNDAVER LABS INC.            Topic: OSD10H09

    This project is divided into a refinement phase and an optional advanced technologies phase. The first year will be devoted to development of a simplified SynDaver Basic (SB) model, a more advanced male full body (SSH-MFB) version of the SynDaver Synthetic Human, and simple sensing technologies to allow the SSH to be used in armor and MRAP development. The second year will focus on development ...

    SBIR Phase II 2013 Department of DefenseDefense Health Agency
  9. Long-lasting Disposable Insecticidal / Repellent Fabric Barrier for Personal or Area Protection Against Biting Arthropods

    SBC: WIDDER BROS INC            Topic: DHP13003

    We propose to build a commercially viable spatial repellency device that requires no outside energy for activation (fire, electricity or air flow). Currently, no other indoor or outdoor spatial device exists that meets these criteria and no other device offers prolonged protection without refilling or replacing the device. Our development work relied heavily on using proven production techniques ...

    SBIR Phase II 2015 Department of DefenseDefense Health Agency
  10. Narrowband Perfect Absorber using Metamaterials

    SBC: PHOEBUS OPTOELECTRONICS LLC            Topic: CBD11102

    We will continue developing a plasmonic metamaterial with strong absorption within a narrow band that is dynamically tunable over the 8-10 micron range. A metamaterial consisting of one or more bi-layers of thin metal and dielectric films will trap, concentrate and absorb a narrow frequency band while strongly reflecting out-of-band light. Tuning the frequency of the absorption band may be achiev ...

    SBIR Phase II 2013 Department of DefenseOffice for Chemical and Biological Defense
US Flag An Official Website of the United States Government