You are here
Award Data
The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.
Download all SBIR.gov award data either with award abstracts (290MB)
or without award abstracts (65MB).
A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.
The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.
-
Botnet Analytics Appliance (BNA)
SBC: MILCORD LLC Topic: N/AAs reported by Internet security threat reports, Bot networks are becoming the focal point for cybercriminals. Milcord and the University of Wisconsin, responds to this challenge with our proposal ¿ a ¿Bayesian Activity Monitor for Botnet Defense¿ (BAM-BD). In this proposal, we will research, design, and develop a botnet detection and mitigation tool that automatically classifies botnet behavio ...
STTR Phase I 2006 Department of Homeland Security -
VOC sensor for Real-Time Physiological Status Monitoring
SBC: TRITON SYSTEMS, INC. Topic: DHP16C002Supplemental oxygen is needed by aircrews and divers. However, oxygen use is limited by the onset of pulmonary oxygen toxicity (PO2T) which can significantly damage pulmonary tissues leading to decreased performance among other adverse effects. A real time sensor that is sensitive and selective with fast response is needed to monitor warfighter breath for trace VOC (volatile organic compound) spe ...
STTR Phase I 2017 Department of DefenseDefense Health Agency -
Biomimetic Slope Adaptive Foot-Ankle Prosthesis
SBC: MOTION CONTROL, INC Topic: DHP16C007Biomimetic Slope Adaptive Foot-Ankle Prosthesis This project will develop an innovative mechanical/hydraulic foot-ankle system that will help lower extremity prosthesis wearers to walk or run in a wider range of environments with close to normal walking biomechanics. The proposed system will have a unique combination of features, all mechanically implemented without electronics or external powe ...
STTR Phase I 2017 Department of DefenseDefense Health Agency -
Passive Pneumatic Prosthetic Ankle with Biomimetic Response
SBC: ADA TECHNOLOGIES, INC. Topic: DHP16C007The Defense Health Program seeks to improve the lives of service members suffering below knee amputations through the development of a non-powered lower extremity prosthesis designed to restore range of motion and power generation to that of an uninjured anatomical ankle. Current passive systems are still in early stages of development and typically only address one aspect of what the Defense Heal ...
STTR Phase I 2017 Department of DefenseDefense Health Agency -
Wearable Medical Electro-textile System for the Warfighter
SBC: TRITON SYSTEMS, INC. Topic: DHA17A001Triton Systems, Inc., teamed with an academic partner, propose to: a) investigate the intensity and shape of the electromagnetic field (EMF) radiated by the human body, and b) develop a simulation of the resulting field to further explore the use of the human EMF to predict warfighter physiological status.
STTR Phase I 2017 Department of DefenseDefense Health Agency -
Electrotextile Systems for Human Signatures Monitoring
SBC: MANTEL TECHNOLOGIES, INC. Topic: DHA17A001Investments by the Department of Defense (DOD) have led to the development and demonstration of electronic textiles capable of transforming traditional textile systems into wearable power and data systems. The Defense Health Agency (DHA) has identified an opportunity to leverage advancements in smart garment systems for military personnel to aid in the prediction in performance declines and healt ...
STTR Phase I 2017 Department of DefenseDefense Health Agency -
Smart Morphing Moulage Medical (SM3) Training Platform
SBC: LUNA INNOVATIONS INCORPORATED Topic: DHA17A002Medical moulage is used in medical training to simulate injuries or pathologies, however current moulage is static and does not provide the trainee feedback on the quality of care or ultimate outcome of that care. Allowing a trainee to witness the injury or pathology -morph- while treatment is being provided can provide feedback on any potential mistreatment and enhance the learning and proficienc ...
STTR Phase I 2017 Department of DefenseDefense Health Agency -
Medic-ART: Medics Augmented Reality Trainer
SBC: APTIMA INC Topic: DHA17A003Navy corpsmen have helped achieve a remarkable survival rate for the warfighters, civilians, and enemy combatants whom they serve. But this success masks significant challenges. Training corpsmen is costly; it addresses primarily the acquisition of skills (rather than maintenance); it fails to convey the perceptual and cognitive skills to handle complex combat wounds; the design of training techno ...
STTR Phase I 2017 Department of DefenseDefense Health Agency -
Wireless Non-Invasive Advanced Control of Microprocessor Prostheses and Orthoses
SBC: LIBERATING TECHNOLOGIES INC Topic: DHA17A005There are several current and imminent orthotic and prosthetic (OandP) fitting scenarios that would greatly benefit from the ability to wirelessly collect and transmit physiological information from the user. Both upper- and lower- limb OandP fittings that: 1) use osseointegration, 2) have cable management issues, and 3) could benefit from physiological information from locations proximal to the ...
STTR Phase I 2017 Department of DefenseDefense Health Agency -
Non-contact Tissue Viability Assessment (NTVA)
SBC: VIVONICS INC Topic: DHA17A006Selecting the level of debridement sufficient to minimize inflammation and determining the optimal treatment in a timely fashion is critical given the risks of infection and sepsis. Grafting success is dependent on the removal of all necrotic tissue and requires the presence of highly-vascularized granulation tissue. The goal of early debridement for grafting is to remove all the devitalized tis ...
STTR Phase I 2017 Department of DefenseDefense Health Agency