You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. High-Throughput, High-Pressure, Small-Angle Neutron Scattering Sample Environment

    SBC: STF TECHNOLOGIES LLC            Topic: 2

    The product to be delivered based on this innovation is a neutron scattering sample environment that enables efficient neutron scattering measurements of biopolymer solutions at high pressure. The proposed high-throughput, high-pressure small-angle neutron scattering (HTHP-SANS) sample environment addresses key customer needs and provides substantial advantages to both the scientific user ...

    SBIR Phase II 2021 Department of CommerceNational Institute of Standards and Technology
  2. High Throughput, High-Pressure Small-Angle Neutron Scattering Sample Environment

    SBC: STF TECHNOLOGIES LLC            Topic: 90

    We address a need of the neutron user community by creating a minimum viable prototype of the only high-throughput hydrostatic pressure small angle neutron scattering sample environment (HTHP-SANS-SE). Our HTHP-SANS-SE will greatly improve the ease of use and reliability of measurements under extreme environments, thereby increasing throughput on the beamline and expanding feasibility. Current HP- ...

    SBIR Phase I 2020 Department of CommerceNational Institute of Standards and Technology
  3. Dynamic Frequency Passive Millemeter-Wave Radiometer Based on Optical Up-Conversion

    SBC: PHASE SENSITIVE INNOVATIONS INC            Topic: 94

    Passive microwave sensors aboard satellites provide valuable information regarding weather conditions by measuring atmospheric attenuation over a broad range of frequencies from 0-200 GHz. Additional ground-based sensors are desirable to provide complementary upward looking measurements that can be used to refine existing attenuation models. Operating over such a large bandwidth, however, places ...

    SBIR Phase II 2014 Department of CommerceNational Oceanic and Atmospheric Administration
  4. Dynamic Frequency Passive Millimeter-Wave Radiometer Based on Optical Up-Conversion

    SBC: PHASE SENSITIVE INNOVATIONS INC            Topic: 941D

    In the proposed effort, we will leverage this extensive experience and capabilities to realize a frequency agile mmW radiometer that can cover the range of DC-110 GHz and can be scaled to DC-200 GHz under Phase II. Ours is a photonic system that multiplies and up-coverts a low-frequency reference signal onto an optical carrier (laser) using EO modulation, then uses the modulation sidebands to inj ...

    SBIR Phase I 2013 Department of CommerceNational Oceanic and Atmospheric Administration
  5. Anion Exchange Resin for Chirality-based Separation of Single-wall Carbon Nanotubes

    SBC: Sepax Technologies, Inc.            Topic: N/A

    Sepax Technologies, Inc. has identified a new type of anoin-exchange resin which separates single-wall carbon nanotubes (SWCNTs) with >80% recovery yield and resolves in a single pass the chiral tubes of (6,5) well from commercial SWCNT starting materials by Chromatography. Improvement and scale up of the targeted resin production will facilitate the separation of chiral nanotubes for the academic ...

    SBIR Phase II 2012 Department of CommerceNational Institute of Standards and Technology
  6. Anion Exchange Resins for Chirality-based Separation of Single-wall Carbon Nanotubes

    SBC: Sepax Technologies, Inc.            Topic: 9060663R

    Single chirality of single-walled carbon nanotubes (SWCNTs) is critical for their superb mechanical, thermal, optical and electronic properties. All known methods for producing nanotubes give mixtures of tubes with different chiralities. Physical separation of SWCNT by chirality is thus an enabling step for many potential applications and fundamental studies. The existing anion exchange resins are ...

    SBIR Phase I 2011 Department of CommerceNational Institute of Standards and Technology
  7. Optical Sensing and Control of Polymer Processing

    SBC: Chemical ElectroPhysics Co. Inc.            Topic: N/A

    A NIST/industry consortium identified accurate temperature distribution measurements, as one of the major technical needs of polymer processors. NIST developed a way to make spatially resolved temperature measurements. Add a small amount of dye. During processing, focus UV illumination onto a small volume element of the process material. Use the ratio of the resulting fluorescent intensities at tw ...

    SBIR Phase I 2002 Department of Commerce
  8. Perflouromembranes for Low Cost Oxygen Enrichment of Aquaculture

    SBC: COMPACT MEMBRANE SYSTEMS, INC.            Topic: N/A

    Success in aquaculture depends heavily on delivery of oxygen to fish. Currently, liquid oxygen and on-site generation by pressure swing adsorption (PSA) are two methods for supplying oxygen to aquaculture. Both are costly and have absorption efficiency problems. Membrane contractors, paddle wheels, and porous pipes are used with limited success to enhance oxygen transport to aquaculture. We ha ...

    SBIR Phase II 1997 Department of Commerce
  9. Perflouromembranes for Low Cost Oxygen Enrichment of Aquaculture

    SBC: COMPACT MEMBRANE SYSTEMS, INC.            Topic: N/A

    N/A

    SBIR Phase I 1996 Department of Commerce
US Flag An Official Website of the United States Government