You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. A Cavity Enhanced Terahertz Absorption Spectrometer (CETAS)

    SBC: ALPHASENSE, INC.            Topic: A08075

    In this proposal, AlphaSense, Inc. (AI) and the Oklahoma State University (OKState) detail the development of a novel Cavity Enhanced Terahertz Absorption Spectrometer (CETAS). Key innovations of the proposed system include: a) the use of a small Whispering- Gallery- Mode (WGM) cavity to achieve very long pathlength; and b) the integration of the WGM cavity with the conventional pulsed and continu ...

    SBIR Phase I 2008 Department of DefenseArmy
  2. Low-Stored-Volume Wings for a Very High Altitude Aircraft

    SBC: ANDREWS SPACE, INC.            Topic: SB072042

    Andrews Space proposes an inflatable rigidizable wing that can be stored folded or rolled up, and deployed at altitude via an inflation system, and will then cure to form a rigid wing improving the reliability and reducing the risk of an inflatable wing. It will also be much lighter and have a much smaller storage volume than a mechanically folding wing. A high altitude, long endurance aircraft c ...

    SBIR Phase I 2008 Department of DefenseDefense Advanced Research Projects Agency
  3. Automated Biological Sample Concentration and Detection System

    SBC: ANP TECHNOLOGIES INC.            Topic: A06T022

    ANP Technologies proposes to integrate a commercially available air sample concentrator from ICx MesoSystems with our automated detection instrument that uses the NIDS® multiplexed assays and NIDS® Auto-Reader (AR) device. A trigger device may also be incorporated into the final system, which might better enable the system to serve as a remote monitor of air streams. The proposed effort will b ...

    STTR Phase II 2008 Department of DefenseArmy
  4. Nano-BiCMOS Night Vision Camera

    SBC: B & W TEK INC            Topic: A08008

    Night vision capability is one of the most important battlefield advantages of the U.S. military, especially in today’s asymmetric warfare. The Gen III night vision goggles in service today is based on the vacuum tube technology with a semiconductor photo cathode, resulting in limitations on view angle, size, manufacturing cost and device operating lifetime. The requirement of special training i ...

    SBIR Phase I 2008 Department of DefenseArmy
  5. High Sensitivity Rugged Array Detectors for Field Deployed Instruments: Low-Light Level Camera for Laser-Induced Breakdown Spectroscopy (LIBS) and Ram

    SBC: B & W TEK INC            Topic: A06065

    Laser-induced breakdown spectroscopy (LIBS) and Raman spectroscopy are developing rapidly for chemical and biochemical sensing applications. There is an urgent need for high-sensitivity detectors so as to minimize sample quantity and maximize detection range from the source. In most field-deployable spectrometers, a photo-detector array is used for analyzing the spectral contents. The sensitivitie ...

    SBIR Phase II 2008 Department of DefenseArmy
  6. METHODOLOGY AND TOOLS FOR ALIGNING VECTOR AND IMAGE DATA

    SBC: BKF Systems            Topic: A06135

    Present methods of vector-raster conflation require extensive human intervention and labor, which is an expensive effort better spent in cognitive, decision-making tasks. Integration or alignment of vector and raster geospatial data may have inaccurate and contradictory geo-references, or not have them at all. Different and unknown rotations, disproportional scales, uncontrolled noise, various p ...

    SBIR Phase II 2008 Department of DefenseArmy
  7. Small Scale Ethanol Drying

    SBC: COMPACT MEMBRANE SYSTEMS, INC.            Topic: N/A

    This program exceeded all key milestones. Using cellulose Waste, CMS demonstrated novel ethanol drying membranes via small scale dephlegmation process that yields fuel grade ethanol (FGE) at a lower cost than large switch grass ethanol plants. This success yields positive value for cellulose waste. We achieved targeted EPA goals of developing low cost environmentally friendly systems to enhance re ...

    SBIR Phase II 2008 Environmental Protection Agency
  8. Optical Modulator Bias Control for Analog Fiber Optic Link Applications

    SBC: EOSPACE INC.            Topic: SB062014

    Typically, the electro-optical Mach-Zehnder interferometric intensity modulator is the key optical component that determines the ultimate performance of an externally-modulated high-performance analog RF fiber-optic link. Intrinsically, the device has a symmetric structure and has a transmission peak at zero bias. In order to operate at the maximum linearity quadrature point, the optical symmetr ...

    SBIR Phase II 2008 Department of DefenseDefense Advanced Research Projects Agency
  9. A Continuous Flow Liquid Cell Holder for the Transmission Electron Microscope

    SBC: HUMMINGBIRD PRECISION MACHINE CO.            Topic: A08T029

    Electron microscopy of specimen in liquid has recently been demonstrated by Niels de Jong at Oak Ridge National Laboratory (ORNL). A sample was enclosed in a liquid compartment with electron transparent windows and imaged using a scanning transmission electron microscope (STEM). Expanding on this expertise it is proposed to develop the technology of a liquid holder for both TEM and STEM that prov ...

    STTR Phase I 2008 Department of DefenseArmy
  10. A Multiplexed Assay for the Detection of Pathogens of Military Importance in Sand Flies

    SBC: Inbios International Inc            Topic: A07150

    Sand flies can cause illnesses such as Leishmaniasis caused by a parasite or sand fly fever due to sand fly fever viruses. The objective of this study is to develop a robust, field grade, screening assay for the detection of both leishmania parasites and/or sand fly fever viruses directly in sand flies. The test will utilize a multi-line lateral flow (dipstick) chromatography incorporated into a c ...

    SBIR Phase II 2008 Department of DefenseArmy
US Flag An Official Website of the United States Government