You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. Frequency Agile LIDAR Receiver for Chem-Bio Sensing

    SBC: PHYSICAL SCIENCES INC.            Topic: CBD06103

    Physical Sciences Inc. proposes to develop an ultra low noise receiver module for direct detection LWIR LIDAR systems. The proposed receiver concept is compatible with emerging LWIR source technologies, e.g., optical parametric amplifier-based sources, as well as existing frequency-agile CO2 laser technology. The optical system will incorporate a rapidly-tunable Fabry-Perot interferometer (etalo ...

    SBIR Phase II 2007 Department of DefenseOffice for Chemical and Biological Defense
  2. Chemical Warfare Agent (CWA) Lightweight Field-Portable (Hand-Held) Medical Diagnostic Tool

    SBC: RAPID PATHOGEN SCREENING, INC.            Topic: CBD06104

    The U.S. Army Medical Research Acquisition Activity at Fort Detrick, MD awarded an SBIR Phase I contract to Rapid Pathogen Screening, Inc. (RPS) in May 2006. The overall objective of this SBIR topic is to develop a lightweight field-portable (i.e., hand-held) device that fulfills a two-fold purpose as follows: (1) it will detect/identify Chemical Warfare Nerve Agents (CWNAs) of operational conce ...

    SBIR Phase II 2007 Department of DefenseOffice for Chemical and Biological Defense
  3. Analysis Tools for Detection and Diagnosis of Biological Threats

    SBC: ALPHA-GAMMA TECHNOLOGIES, INC.            Topic: CBD04113

    DNA microarray technology, in combination with statistical and predictive modeling tools, could be used to evaluate thousands of genes against distinct gene expression patterns induced by chemical/biological agents to provide early identification and speed therapeutic intervention. The overall objective of this Phase II effort is to leverage existing public domain resources and commercial tools t ...

    SBIR Phase II 2005 Department of DefenseOffice for Chemical and Biological Defense
  4. Novel THz-frequency spectrometers by integrating widely-tunable monochromatic THz sources and detectors, or arrays of emitters and detectors, with pho

    SBC: ArkLight            Topic: CBD04104

    By continuing teaming up with one of the most reputable university teams in THz science and technology, ArkLight proposes to carry out the tasks set for a Phase-II program following our success in Phase I. We are aimed at the further development of novel spectrometers to analyze chemicals in the vapor phase based on accurate measurements of the emission and absorption spectra due to the molecular ...

    SBIR Phase II 2005 Department of DefenseOffice for Chemical and Biological Defense
  5. Monitoring Food and Water for Pathogens

    SBC: BIOSCALE, INC.            Topic: CBD03201

    Having achieved or exceeded all goals and objectives of the Phase I research program, BioScale has thus demonstrated feasibility of a multiplexed, immuno-electromechanical pathogen detection method. In Phase II, BioScale proposes to advance this research by assembling a complete assay system that integrates discrete, commercial off the shelf (COTS) sample preparation subcomponents with the propri ...

    SBIR Phase II 2005 Department of DefenseOffice for Chemical and Biological Defense
  6. Model-Based Design of Test Systems for Chemical Protective Clothing

    SBC: CREARE LLC            Topic: CBD02202

    The current methodology for testing the penetration resistance of textile materials to various chemical agents has a number of drawbacks, including significant uncertainties in the resulting data, inefficiency and expense, risk to test personnel, and limited range of test conditions. The objective of the proposed work is to apply unique computer models for textiles with accompanying experimental ...

    SBIR Phase II 2005 Department of DefenseOffice for Chemical and Biological Defense
  7. Hermetic Textile Closure Hardware System

    SBC: SIGMA K CORP            Topic: CBD04110

    Effective collective protection fabrics must have a reliable closure system. During our Phase I Work Plan, Sigma-K began developing a Hermetic Textile Closure Hardware (HATCH) system. The HATCH combines both a magnetic and geometric self locking mechanism that will provide a hermetic seal when closed. Our current Phase I successes include developing self closing samples that can provide a hermetic ...

    SBIR Phase II 2005 Department of DefenseOffice for Chemical and Biological Defense
US Flag An Official Website of the United States Government