  1. Analysis Tools for Detection and Diagnosis of Biological Threats

    SBC: ALPHA-GAMMA TECHNOLOGIES, INC.            Topic: CBD04113

    DNA microarray technology, in combination with statistical and predictive modeling tools, could be used to evaluate thousands of genes against distinct gene expression patterns induced by chemical/biological agents to provide early identification and speed therapeutic intervention. The overall objective of this Phase II effort is to leverage existing public domain resources and commercial tools t ...

    SBIR Phase II 2005 Department of DefenseOffice for Chemical and Biological Defense
  2. Detectors with Integrated Filters for Solar VUV Observations

    SBC: International Radiation Detectors, Inc.            Topic: 816

    Fabrication of stable, nearly 100% internal carrier collection efficiency silicon photodiodes (AXUV diodes) for 1 nm to 600 nm photons was successfully demonstrated by us several years ago. Owing to their excellent characteristics, these devices are being used by NIST as transfer standards in 5 nm to 250 nm range and aboard SOHO, SNOE and TIMED instruments for the EUV solar spectrum studies. Alt ...

    SBIR Phase II 2005 Department of Commerce
  3. LOW COST HRPT DIRECT READOUT STATION

    SBC: International Systems & Soft-            Topic: N/A

    THIS ABSTRACT COVERS THE PROPOSED DESIGN OF A LOW COST HRPT DIRECT READOUT STATION FOR A COST OF LESS THAN $100K DOLL ARS. THIS CONCEPT UTILIZES STATE-OF-THE-ART TECHNOLOGY PROVEN SUCCESSFUL IN COMMERCIAL APPLICATIONS. THE SUCCESSFULDEVELOPMENT OF THE LOW-COST HRPT STATION WILL OPEN A COMMERCIAL AND GOVERNMENT MARKET THAT HAS A NEED FOR CURRENT WEATHER INFORMATION. THESE POTENTIAL USERS HAVE DELAY ...

    SBIR Phase II 1987 Department of Commerce
  4. An Innovative Raster-Mirror Optical Detection System for CCD Camera Bistatic Lidar

    SBC: METROLASER, INCORPORATED            Topic: 812

    An innovative optical system with 500X higher ¿tendu and spatial resolution will be designed for CCD-based bistatic lidar. A 100¿ vertical field of view is required to image the laser beam from the ground through the boundary layer, but only a few degrees are required in the horizontal direction. The proposed design is based on dividing the vertical field of view into N sectors, using 1D rasteri ...

    SBIR Phase II 2005 Department of Commerce
  5. Ultra-High Vacuum Compatible Wavelength Dispersive X-ray Spectrometer

    SBC: PARALLAX RESEARCH INC            Topic: N/A

    Parallax Research, Inc. proposes to build an Ultra-High Vacuum compatible Wavelength Dispersive X-ray Spectrometer (WDS) that can be used on small spot Auger, XPS, TEM and FESEM analytical instruments for elemental analysis. The effort draws upon Parallax's experience in designing WDS systems for Scanning Electron Microscopes (SEM) and for XRF. This new type of x-ray spectrometer will eliminate th ...

    SBIR Phase II 2005 Department of CommerceNational Institute of Standards and Technology
  6. Hermetic Textile Closure Hardware System

    SBC: SIGMA K CORP            Topic: CBD04110

    Effective collective protection fabrics must have a reliable closure system. During our Phase I Work Plan, Sigma-K began developing a Hermetic Textile Closure Hardware (HATCH) system. The HATCH combines both a magnetic and geometric self locking mechanism that will provide a hermetic seal when closed. Our current Phase I successes include developing self closing samples that can provide a hermetic ...

    SBIR Phase II 2005 Department of DefenseOffice for Chemical and Biological Defense
  7. FIBER OPTIC CHEMICAL SENSORS (FOCS) FOR THE MEASUREMENT OF PH, CO2 AND O2 IN SEAWATER

    SBC: St&e Inc            Topic: N/A

    THE USE OF THE FIBER OPTIC CHEMICAL SENSORS (FOCS) IS A DIRECT RESPONSE TO NOOAA'S NEED FOR BETTER OCEAN INSTRUMENT ATION AND MEASUREMENT SYSTEMS. "SMALL CHEMISTRY LABORATORIES" ARE ATTACHED TO THE DISTAL END OF OPTICAL FIBERS TO SPECIFIC, SENSITIVE MEASUREMENTS OF PRESELECTED SPECIES. 4589 THE REGIONAL OFFICE. DETECTION AND QUANTIFICATION OF CO2 AND O2 WILL BE RESEARCH ED AND DEVELOPED. SPECIFIC ...

    SBIR Phase II 1987 Department of Commerce
  8. An Autonomous Gas Chromatograph for Measurement of Greenhouse Gases in Airborne Applications

    SBC: SONOMA TECHNOLOGY, INC.            Topic: 815

    An automated, high precision, lightweight gas chromatograph, capable of measuring hydrogen (H2), methane (CH4), carbon monoxide (CO) and carbon dioxide (CO2) with a fast duty cycle (1 sample per two minutes) will be designed and built. The detector used for the chromatograph will be an electron capture detector with sensitivity enhanced by addition of nitrous oxide (N2O) reagent gas. The instrum ...