  1. Demonstration of a Continuous, Real-Time PM2.5 Chemical Speciation Monitor Based on an Aerosol Mas Spectrometer

    SBC: AERODYNE RESEARCH INC            Topic: N/A

    This Small Business Innovation Research Phase II project addresses the need for improved monitoring technologies for continuous particulate mass and chemical speciation of ambient aerosols. Aerodyne Research, Inc. will develop a prototype Aerosol Chemical Speciation Monitor (ACMS) that measures ambient aerosol mass and chemical composition of non-refractory submicron aerosol particles in real-tim ...

    SBIR Phase I 2004 Environmental Protection Agency
  2. Use of a Genetically Modified Organism To Assess Sewer Line Integrity

    SBC: BioTrackers            Topic: N/A

    When sewer exfiltration leaks into the environment, the entry of fecal bacteria into groundwater and surface water increases health risks. Leaking sewers also are suspected sources of fecal contamination in many surface waters designated for total maximum daily load (TMDL) plans. Development of TMDL plans has been hindered by the lack of a reliable and cost-effective method to identify fecal con ...

    SBIR Phase I 2004 Environmental Protection Agency
  3. MEMS-Based Volatile Organic Compound Monitor

    SBC: BOSTON MICROSYSTEMS INC            Topic: N/A

    Boston MicroSystems, Inc. (BMS), proposes to develop a MicroElectroMechanical System (MEMS) based volatile organic compound (VOC) monitor by integrating analyte-specific polymer films with SiC-AlN microresonators. In this research project, BMS and the Naval Research Laboratory will integrate microresonators and polymer films with functional groups sensitive to aromatic compounds (e.g., benzene an ...

    SBIR Phase I 2004 Environmental Protection Agency
  4. Novel Ceramic Membrane Bioreactor for Low-Flow Systems

    SBC: Ceramem Corporation            Topic: N/A

    Improved low-flow (50,000 gallons per day) sanitary wastewater treatment systems are needed. CeraMem Corporation¿s proposed approach includes a membrane bioreactor (MBR) using fully proven biological processes for biological oxygen demand oxidation and (optionally) for nutrient removal (i.e., denitrification and phosphorus removal). The technology has as a key inventive element¿a novel, compac ...

    SBIR Phase I 2004 Environmental Protection Agency
  5. Ultrasensitive Toxic Chemical Detector

    SBC: Implant Sciences Corporation            Topic: N/A

    The ability to detect and identify trace quantities of hazardous materials has become a significant requirement for protecting the population during the war on terrorism. However, the ability to detect and identify trace concentrations of a wide range of chemicals in the field using a man-portable instrument is severely limited. The ability to quickly and reliably identify toxic industrial chemi ...

    SBIR Phase I 2004 Environmental Protection Agency
  6. Fiberoptic Diisocyanate Personal Monitoring Device

    SBC: LIGHTLINE TECHNOLOGIES INC            Topic: N/A

    LightLine Technologies proposes to develop a highly sensitive fiberoptic personal monitoirng device similar to a sampling badge, targeted for the simple and conventional measurement of total isocyanate and diisocyanate (I&DCY) airbourne exposure. With verymodest smapling processing (controlled heating) sensing of all types of I&DCYs will be possige and is the ptimary goal of this program. Ths sa ...

    SBIR Phase I 2005 Environmental Protection Agency
  7. Wafer Level Supercritical Carbon Bioxide-Based Metal Depositon for Microelectronic Applications

    SBC: MiCell Technologies, Inc.            Topic: N/A

    This proposal describes the application, development and commercial scale-up of a process successfully developed under EPA contract number EP-D-04-042 for the deposition of copper and copper barrier materials such as ruthenium, titanium and other metals. This process could replace CU electroplating currently used to fill deep trenches and thin film deposition in microelectronic circuit manufactur ...

    SBIR Phase I 2004 Environmental Protection Agency
  8. Identification and Sorting of Printed Wiring Boards (PWB) Within an E-Waste Recycling Stream

    SBC: National Recovery Technologies LLC            Topic: N/A

    Electoronic waste (e-waste) is one of the most rapidly growing waste problems worldwide. Improper handling of e-waste results in vast amounts of toxic waste being sent to landfill and leaching into the water supply. Due to these concerns e-waste recycling is a rapidly growing industry. Unfortunately, most current e-waste recycling processes rely on either manual hand sorting or differental dens ...

    SBIR Phase I 2005 Environmental Protection Agency
  9. Sterilizing Medical Equipment with One Atmosphere Uniform Glow Discharge Plasma

    SBC: Atmospheric Glow Technologies            Topic: C3NCERA1

    The goal of this Phase I research project is to investigate the feasibility and commercial potential of using the One Atmosphere Uniform Glow Discharge Plasma (OAUGDP™) as a low-temperature sterilization process for medical equipment. Current sterilization technologies that pose a risk to health care workers and the environment are being phased out of use (e.g., ethylene oxide steril ...

    SBIR Phase I 2004 Environmental Protection Agency
  10. Demonstration of a Continuous, Real-Time PM2.5 Chemical Speciation Monitor Based on an Aerosol Mass Spectrometer

    SBC: AERODYNE RESEARCH INC            Topic: C3NCERA2

    This Phase I research project addresses the need for improved monitoring technologies for continuous particulate mass and chemical speciation of ambient aerosols. During the last few years, Aerodyne Research, Inc., has developed an Aerosol Mass Spectrometer (AMS) instrument that measures ambient aerosol mass, chemical composition, and chemically speciated size distributions of nonre ...

    SBIR Phase I 2004 Environmental Protection Agency