You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. THIN PLASTIC FILMS WITH ELECTRICALLY CONTROLLABLE REFLECTIVITY/TRANSMISSIVITY TO VISUAL OR INFRARED

    SBC: AST PRODUCTS, INC.            Topic: N/A

    N/A

    SBIR Phase I 1990 Department of DefenseDefense Advanced Research Projects Agency
  2. COATING FOR IMPLANTABLE BIOSENSORS

    SBC: AST PRODUCTS, INC.            Topic: N/A

    N/A

    SBIR Phase I 1990 National Science Foundation
  3. OPTIMIZING A LOCAL WEATHER FORECAST MODEL

    SBC: ATMOSPHERIC & ENVIRONMENTAL RESEARCH, INC.            Topic: N/A

    N/A

    SBIR Phase I 1990 National Science Foundation
  4. A CARBON-13 ISOTOPE ANALYZER

    SBC: AERODYNE RESEARCH INC            Topic: N/A

    ISOTOPIC CARBON ANALYSIS PROVIDES A VALUABLE TOOL FOR STUDIES OF METABOLIC PATHWAYS AND FOR TRACING CARBON TRANSFORMATIONS IN THE ENVIRONMENT. THIS PROPOSAL WOULD DEVELOP AN OPTICAL TECHNIQUE FOR THE CONVENIENT MEASUREMENT OF CARBON ISOTOPIC ((13)C/(12)C) RATIOS. THE INSTRUMENT WILL UTILIZE A LINEAR PHOTODIODE ARRAY TO IMAGE THE SPECTRA ARISING FROM PLASMA EMISSION OF THE CARBON-CONTAINING MOLECUL ...

    SBIR Phase II 1990 National Science Foundation
  5. LONG-PATH INTRACAVITY LASER SPECTROMETER FOR THE MEASUREMENT OF ATMOSPHERIC TRACE GASES

    SBC: AERODYNE RESEARCH INC            Topic: N/A

    WE PROPOSE TO INVESTIGATE A TECHNIQUE FOR INCREASING THE SENSITIVITY OF INTRACAVITY LASER ABSORPTION SPECTROSCOPY, WITH APPLICATION TO THE DETECTION AND MEASUREMENT OF TRACE GASES IN THE ATMOSPHERE. THE TECHNIQUE THAT WE WILL INVESTIGATE IS TO PLACE A MULTIPASS ABSORPTION CELL WITHIN THE RESONANT CAVITY OF A DYE LASER. WITH AN INTRACAVITY MULTIPASS CELL, THE OPTICAL ABSORPTION PATHLENGTH CAN BE IN ...

    SBIR Phase I 1990 National Science Foundation
  6. A POSITION SENSITIVE NEUTRON DETECTOR USING BORON PHOSPHIDE SEMICONDUCTOR SENSORS

    SBC: RADIATION MONITORING DEVICES, INC.            Topic: N/A

    TRADITIONAL POSITION-SENSITIVE NEUTRON DETECTORS USE EITHER GAS FILLED TUBES OR SCINTILLATOR-PHOTOMULTIPLIER TUBE COMBINATIONS. ALTHOUGH BOTH OF THESE TECHNOLOGIES HAVE RESULTED IN SUCCESSFUL POSITION-SENSITIVE NEUTRON DETECTORS,THEY HAVE A VARIETY OF INTRINSIC DEFICIENCIES. THIS PROJECTINVOLVES THE CONSTRUCTION OF NEW POSITION-SENSITIVE NEUTRON DETECTORS FROM SOLID STATE DETECTOR ELEMENTS MADE FR ...

    SBIR Phase II 1990 Department of Energy
  7. AUTOMATIC CONTROL OF INTERFACE BOUNDARIES IN VERTICAL FREEZEPRODUCTION PROCESSES

    SBC: RADIATION MONITORING DEVICES, INC.            Topic: N/A

    A KEY CONSIDERATION IN A VARIETY OF MANUFACTURING PROCESSES IS CONTROLLING EITHER THE POSITION OR SHAPE OF AN INTERFACE DEFINED AS THE BOUNDARY BETWEEN LIQUID AND SOLID MATERIALS OF DISSIMILAR COMPOSITION OR DENSITY TO WITHIN CERTAIN ALLOWABLE TOLERANCES. EXAMPLES OF SUCH DIVERSE PROCESSES ARE VERTICAL FREEZE BRIDGMAN AND CZOCHRALSKI CRYSTAL GROWTH AND ELECTROSLAG REMELTING FOR METAL REFINEMENT. A ...

    SBIR Phase II 1990 National Science Foundation
  8. THALLIUM BROMOIODIDE DETECTORS FOR SCINTILLATION SPECTROSCOPY

    SBC: RADIATION MONITORING DEVICES, INC.            Topic: N/A

    SCINTILLATION DETECTORS REMAIN THE LEADING TYPE OF DETECTOR IN MANY AREAS OF NUCLEAR PHYSICS. ALTHOUGH IMPROVEMENTS IN SCINTILLATOR CRYSTAL TECHNOLOGY HAVE EXTENDED THE UTILITY OFSCINTILLATOR SYSTEMS, SERIOUS DEFICIENCIES IN THE OPTICAL DETECTORS USED WITH SCINTILLATION CRYSTALS LIMIT THE TECHNOLOGY'S FULL POTENTIAL. CONVENTIONAL SCINTILLATION SYSTEMS USE PHOTOMULTIPLIER TUBES OR SILICON DIODES AS ...

    SBIR Phase II 1990 Department of Energy
  9. THALLIUM BROMIDE X-RAY PHOTCATHODES

    SBC: RADIATION MONITORING DEVICES, INC.            Topic: N/A

    X-RAY PHOTOCATHODES ARE USED IN A LARGE NUMBER OF X-RAY IMAGING SYSTEMS, MAINLY IN THE FIELDS OF ASTRONOMY AND MEDICAL IMAGING. IN MOST APPLICATIONS, X-RAY PHOTOCATHODES ARE USED IN CONJUNCTION WITH A MICROCHANNEL PLATE (MCP) AND A POSITION-SENSITIVE DETECTOR. DEVICES INCORPORATING THIS COMBINATION ARE CAPABLE OF IMAGING X-RAYSWITH VERY HIGH SPATIAL AND TEMPORAL RESOLUTION. MANY DIFFERENT X-RAY PH ...

    SBIR Phase I 1990 National Science Foundation
  10. SOLID STATE, ON-LINE DETECTION SYSTEM FOR CAPILLARY ELECTROPHORESIS

    SBC: RADIATION MONITORING DEVICES, INC.            Topic: N/A

    ELECTROPHORESIS IS ONE OF THE MOST IMPORTANT AND WIDELY USED ANALYTICAL TECHNIQUES FOR THE SEPARATION AND IDENTIFICATION OF BIOLOGICAL MOLECULES. RECENTLY, THERE HAS BEEN A SIGNIFICANT ADVANCE IN ELECTROPHORESIS TECHNOLOGY THROUGH THE USE OF GEL GEOMETRIES INVOLVING THIN CAPILLARY TUBES. THIS TECHNOLOGY HAS BEEN DEVELOPED INTO A NEW SEPARATION TECHNIQUE, CAPILLARY ZONE ELECTROPHORESIS (CZE) AND IS ...

    SBIR Phase I 1990 National Science Foundation
US Flag An Official Website of the United States Government