You are here
Award Data
The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.
Download all SBIR.gov award data either with award abstracts (290MB)
or without award abstracts (65MB).
A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.
The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.
-
IMAGINE: Imagery Management through Agile, Geo-Interactive, Natural Embodiment
SBC: APTIMA INC Topic: NGA11002Overhead imagery analysts employ computer-based software as Electronic Light Tables (ELTs), to perform detailed analysis of aerial images in search of elements of interest. Conventional display design for ELT software requires analysts to take their eyes away from the image they are analyzing to perform routine functions. This interaction overhead typically leads to losses in visual momentum and i ...
SBIR Phase I 2011 Department of DefenseNational Geospatial-Intelligence Agency -
Helicopter Hostile Fire Indication Sensor
SBC: Agiltron Development Corporation Topic: SOCOM11001Agiltron Development Corp. will develop the world"s first affordable, reliable and accurate Helicopter Hostile Fire Indicator Sensor capable of detecting small arms through rocket propelled grenade threats using Agiltron"s unique photomechanical, uncooled infrared sensor. In phase one, Agiltron will construct a test sensor system and conduct field tests to determine detection range, accuracy and f ...
SBIR Phase I 2011 Department of DefenseSpecial Operations Command -
Rapid, Quantitative Biological Indicator System with Bacillus thuringiensis Al Hakam Spores(1001-677)
SBC: TRITON SYSTEMS, INC. Topic: CBD11101Biological agents pose high threats, because they are invisible and odorless and a relatively small amount can infect a large population when released in a densely populated area. For the same reasons, assuring safety after cleaning decontaminated sites can be challenging. Currently available technologies require considerable labor, and results typically cannot be obtained before 24 V 48 hours up ...
SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense -
Ruggedized FTIR Spectrometer Based on Calomel Prisms
SBC: AGILTRON, INC. Topic: CBD11104Leveraging on Agiltron industry leading development of optical systems and the PI experience with FTIR spectrometer design, we propose to develop a new class of compact monolithic Fourier-transform spectrometers for the long-wave (7.5-13 m) infrared optical range. The proposed solution is based on creating a spatial interferogram with a pair of a calomel Wollaston prisms and digitizing it with an ...
SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense -
Non-Toxic Obscurants and Dispersal System
SBC: PHYSICAL SCIENCES INC. Topic: SOCOM06007SOCOM and other DOD services have urgent need for safe, non-toxic visual obscurants that can be rapidly dispersed in a battlefield or into a vehicle. These obscurants must block or disrupt all visual capability within their area of effect. The dispersion must be rapid and easy to implement by field personnel. Physical Sciences Inc. (PSI) will develop a non-toxic obscurant and dispersion system c ...
SBIR Phase II 2011 Department of DefenseSpecial Operations Command -
Low noise longwave infrared (8-12µm) focal plane array with high sensitivity for passive hyperspectral standoff detection
SBC: APPLIED NANOFEMTO TECHNOLOGIES LLC Topic: CBD10105Longwave infrared (LWIR, 8-12µm) focal plane arrays (FPAs) play an important role in hyperspectral chemical and biological (CB) sensing and spectral imaging. Existing thermal detectors are unable to meet the high sensitivity and fast response requirements of many hyperspectral chemical and biological sensing applications. FPAs based on photon excited electron generation process can fulfill the sp ...
SBIR Phase II 2011 Department of DefenseOffice for Chemical and Biological Defense -
MEMS Lamellar Based Interferometer for the Detection of Toxic Chemicals
SBC: AGILTRON, INC. Topic: CBD10104Leveraging on Agiltron industry leading development of optical MEMS devices and the PI experience with FTIR spectrometer design, we propose to develop a new class of high performance compact and rugged FTIR spectrometers for the LWIR optical range. The design is based on the MEMS lamellar mirror technique. Although this approach is not new, it has not yet been efficiently applied to LWIR, and per ...
SBIR Phase II 2011 Department of DefenseOffice for Chemical and Biological Defense -
Low Cost and Rapid DNA-Based Biometric Device
SBC: NetBio, Inc. Topic: HSB091001Sensitive site exploitation activities are focused on collecting forensic evidence left behind by persons involved in terrorist or other illegal activity, and the biological evidence recovered is often referred to as"touch DNA samples". Touch samples include fingerprints, skin cells found on clothing (e.g. a shirt collar), and oral epithelial cells found on the opening of a soda can or the rim of ...
SBIR Phase II 2011 Department of DefenseSpecial Operations Command -
Nanoparticle Based Hand-Portable Waterless Decontamination System
SBC: CHEMMOTIF, INC. Topic: N/AChemMotif has developed several new colorimetric vapor sensors. These will be tested as end-of-service-life indicators for carbon-filter gas-masks in Chemical Biological Defense applications.Modification of the ChemMotif sensors will be done to demonstrate their potential to meet the ESLI requirements.These sensors will permit safer and more cost-effective use of gas-mask carbon filters.Low-cost ...
SBIR Phase I 2001 Department of DefenseOffice for Chemical and Biological Defense -
High-Pulse-Rate IR Source for Improved DIAL Sensitivity
SBC: EIC LABORATORIES, INC. Topic: N/AThe Joint Service Agent Water Monitor (JSAWM) has several challenging operational requirements for detecting and monitoring chemical and biological warfare (CBW) contaminants in water supplies. Surface Enhanced Raman Spectroscopy (SERS) can providespecific spectroscopic
SBIR Phase I 2001 Department of DefenseOffice for Chemical and Biological Defense