You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. Ultra High-Speed Spectroradiometry for Contamination Reconnaissance and Surveillance

    SBC: SPECTRAL SCIENCES, INC            Topic: CBD09107

    Spectral Sciences, Inc. proposes an innovative ultrafast spectroradiometer for transient thermal event detection at surfaces in order to provide contamination avoidance and mitigation. The proposed system combines an adaptive, software programmable spectral filter with advanced signal processing algorithms to identify contaminates based on transient thermal excitation of a sample. The adaptive s ...

    SBIR Phase I 2009 Department of DefenseOffice for Chemical and Biological Defense
  2. Spectroscopic high throughput identification of protein variants

    SBC: LEXITEK INC            Topic: CBD09104

    Quantitative Raman spectroscopy offers a means of estimating concentrations of protein variants. The Raman spectrum can be a fingerprint of an individual molecule and features unique to functional groups. In conjunction with robust data analysis such as principal component analysis (PCA), chemometric assessment of a sample can be performed. As an optical technique, this approach can yield high-thr ...

    SBIR Phase I 2009 Department of DefenseOffice for Chemical and Biological Defense
  3. Sensor Fusion Software Tool for CBRN Global Threat Prediction and Assessment

    SBC: PHYSICAL SCIENCES INC.            Topic: CBD09110

    Physical Sciences Inc. (PSI) proposes to develop a software tool that is capable of fusing disparate data sources including hyperspectral standoff sensor data products, weather information, and point sensor data generated from a deployed network of sensors. The proposed software suite will be based on an algorithm that will compute the threat type, spatial and temporal concentration profiles as we ...

    SBIR Phase I 2009 Department of DefenseOffice for Chemical and Biological Defense
  4. Ruggedized FTIR Spectrometer Based on Calomel Prisms

    SBC: AGILTRON, INC.            Topic: CBD11104

    Leveraging on Agiltron industry leading development of optical systems and the PI experience with FTIR spectrometer design, we propose to develop a new class of compact monolithic Fourier-transform spectrometers for the long-wave (7.5-13 m) infrared optical range. The proposed solution is based on creating a spatial interferogram with a pair of a calomel Wollaston prisms and digitizing it with an ...

    SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense
  5. Rapid, Quantitative Biological Indicator System with Bacillus thuringiensis Al Hakam Spores(1001-677)

    SBC: TRITON SYSTEMS, INC.            Topic: CBD11101

    Biological agents pose high threats, because they are invisible and odorless and a relatively small amount can infect a large population when released in a densely populated area. For the same reasons, assuring safety after cleaning decontaminated sites can be challenging. Currently available technologies require considerable labor, and results typically cannot be obtained before 24 V 48 hours up ...

    SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense
  6. Polymeric Agent Decontamination System

    SBC: PHYSICAL SCIENCES INC.            Topic: N/A

    The threat of military and terrorist deployment of chemical weapons has increased alarmingly in recent years. A universal decontamination system is required for safe and effective neutralization of standard and thickened chemical warfare agents (G, V, and H). The system must be non-toxic, non-corrosive, and non-hazardous to equipment and personnel. For effective implementation, the system must be ...

    SBIR Phase I 1998 Department of DefenseOffice for Chemical and Biological Defense
  7. Novel Microcantilever Biosensor for the Measurement of Biomolecular Forces

    SBC: LUNA INNOVATIONS INCORPORATED            Topic: N/A

    The ability to detect minute quantities of toxic biological substance s will provide the ability to quickly assess a situation so that an a ppropriate response to exposure can be orchestrated. Not only will t he development of this technology be important in toxic agent warfare detection, the biological sensors would be pertinent in commercial ap plications such as process control and point-of-ca ...

    SBIR Phase I 1998 Department of DefenseOffice for Chemical and Biological Defense
  8. Minature Biological Detector Using On-Chip Eletrostatic Spray Separation

    SBC: American Research Corporation of Virginia            Topic: N/A

    Recent developments in the world political arena have led to The need for miniaturized instrumentation for rapid characterization of micro-organisms and toxins to protect military and civilian personnel against biological weapons and to allow timely administration of prophylactics. Considerable effort is currently underway to develop polymerase chain reaction (PCR) assays with automated samp ...

    SBIR Phase I 1998 Department of DefenseOffice for Chemical and Biological Defense
  9. MEMS Lamellar Based Interferometer for the Detection of Toxic Chemicals

    SBC: AGILTRON, INC.            Topic: CBD10104

    Leveraging on Agiltron industry leading development of optical MEMS devices and the PI experience with FTIR spectrometer design, we propose to develop a new class of high performance compact and rugged FTIR spectrometers for the LWIR optical range. The design is based on the MEMS lamellar mirror technique. Although this approach is not new, it has not yet been efficiently applied to LWIR, and per ...

    SBIR Phase II 2011 Department of DefenseOffice for Chemical and Biological Defense
  10. Low noise longwave infrared (8-12µm) focal plane array with high sensitivity for passive hyperspectral standoff detection

    SBC: APPLIED NANOFEMTO TECHNOLOGIES LLC            Topic: CBD10105

    Longwave infrared (LWIR, 8-12µm) focal plane arrays (FPAs) play an important role in hyperspectral chemical and biological (CB) sensing and spectral imaging. Existing thermal detectors are unable to meet the high sensitivity and fast response requirements of many hyperspectral chemical and biological sensing applications. FPAs based on photon excited electron generation process can fulfill the sp ...

    SBIR Phase II 2011 Department of DefenseOffice for Chemical and Biological Defense
US Flag An Official Website of the United States Government