You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. Enhanced Beta-Batteries: A Long Life Power Source for Sensors Monitoring WMD

    SBC: RADIATION MONITORING DEVICES, INC.            Topic: DTRA102004

    While many applications may have access to harvestable energy in the form of solar radiation (or other ambient light), wind, environmental vibration, or wave motion, not all do. In this proposal, RMD targets the most challenging applications, sensors that must operate for many months or years and which have undependable or no access to environmental energy. These sensors need a self contained, com ...

    SBIR Phase II 2012 Department of DefenseDefense Threat Reduction Agency
  2. Advanced nanocomposite scintillator for gamma radiation detection

    SBC: AGILTRON, INC.            Topic: DTRA08005

    Until now gamma radiation detection has required large single crystals of sensitive materials that are difficult to produce consistently on an industrial scale. In collaboration with a research group at the University of Texas at Arlington, Agiltron proposes to develop a new class of nanocomposite scintillator materials. The radiation detection characteristics of the synthetic nanoparticles in the ...

    SBIR Phase I 2008 Department of DefenseDefense Threat Reduction Agency
  3. Improvements in Scintillation Technology for Detection of Nuclear Radiation

    SBC: RADIATION MONITORING DEVICES, INC.            Topic: DTRA07004

    High-resolution scintillation crystals and crystal arrays are important components of current and future handheld and arrayed detectors (used for DOD/DTRA applications), and scintillation spectrometers (routinely used in high energy physics research, medical imaging, diffraction, homeland security, nuclear waste clean-up, nuclear treaty verification and safeguards, and geological exploration). Un ...

    SBIR Phase II 2008 Department of DefenseDefense Threat Reduction Agency
  4. Portable Time of Flight Mass Spectrometer for Nuclear Forensics

    SBC: CREARE LLC            Topic: DTRA08004

    Analysis of nuclear material samples in the field has many advantages over laboratory analysis. Laboratory analyses can be slow, involve increased expense, lead to additional waste generation and disposal problems, and may introduce errors due to sample degradation or mishandling. In situ analysis mitigates all of these problems. The specific aim of this project is the development of a truly por ...

    SBIR Phase I 2008 Department of DefenseDefense Threat Reduction Agency
  5. AN OPTICAL FIBER INTRUSION LOCATION (FIBLOC) SENSOR FOR SURFACE AND SUBSURFACE PERIMETER PROTECTION

    SBC: Anro Engineering, Inc.            Topic: N/A

    THE PROPOSED FIBLOC SENSOR PROVIDES AN ECONOMIC MEANS TO PROTECT, LITERALLY, MILES OF A PREFERRED PERIMETER REGION AGAINST UNAUTHORIZED INTRUSIONS. THE OPTICAL FIBERS EMPLOYED INT HE FIBLOC SENSOR PROPAGATE CW OR PULSED INFRARED LIGHT SIGNALS WHOSE TRANSMISSION AND/OR REFLECTION SENSITIVITY IS AFFECTED BY MECHANICAL PRESSURE SUCH AS WOULD BE PRODUCED BY THE DISTENSION OF SURFACED MOUNTED FIBERS AL ...

    SBIR Phase I 1988 Department of DefenseDefense Threat Reduction Agency
  6. FIBER OPTIC GROUND MOTION SENSOR

    SBC: GEO-CENTERS, INC.            Topic: N/A

    THE PHASE I EXPERIMENTAL EFFORT WILL DEMONSTRATE THE FEASIBILITY OF A FIELD WORTHY GROUND MOTION SENSOR TO REPLACE PIEZO-ELECTRIC ACCELEROMETERS FOR CONVENTIONAL EXPLOSIVES AND NUCLEAR TESTING. THE OUTPUT SIGNALS OF PIEZO-ELECTRIC ACCELEROMETERS MUST BE INTEGRATED TWICE TO DETERMINE GROUND MOTIONS. THIS PROCESS REDUCES SYSTEM ACCURACY AND MEASUREMENT BANDWIDTH. ADDITIONALLY, AS PIEZO-ELECTRIC SENS ...

    SBIR Phase I 1988 Department of DefenseDefense Threat Reduction Agency
  7. DEFECT REDUCTION IN SIMOX WAFERS

    SBC: Spire Corporation            Topic: N/A

    CREATION OF BURIED INSULATING LAYERS IN SILICON WAFERS BY HIGH DOSE OXYGEN IMPLANTATION (SIMOX) HAS GAINED SIGNIFICANT ATTENTION IN THE LAST TWO YEARS. THE SIMOX TECHNOLOGY IS POSITIONED TO BE A PRIME CONTENDER IN THE SILICON-ON-INSULATOR (SOI) ARENA MAINLY BECAUSE OF THE INHERENT RELIABILITY/REPRODUCIBILITY OF THE ION IMPLANTATION TECHNOLOGY. ONE OBSTACLE TO BROADER USE OF THE SIMOX MATERIAL IS T ...

    SBIR Phase I 1988 Department of DefenseDefense Threat Reduction Agency
US Flag An Official Website of the United States Government