You are here
Award Data
The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.
Download all SBIR.gov award data either with award abstracts (290MB)
or without award abstracts (65MB).
A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.
The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.
-
Intravascular Cardiac Assist System for Decompression and Recovery
SBC: ABIOMED, INC. Topic: NHLBIDESCRIPTION (provided by applicant): The objective of this proposal is to develop a less invasive long-term copulsation device to treat patients in late Class III and early Class IV stages of heart failure (HF). Chronic congestive heart failure is the largest unsolved problem in cardiac care today. There are over 5.5 million people in the United States with this diagnosis and the number of patient ...
SBIR Phase II 2010 Department of Health and Human ServicesNational Institutes of Health -
A Novel Polymeric Percutaneous Heart Valve Prosthesis
SBC: ABIOMED, INC. Topic: NHLBIDESCRIPTION (provided by applicant): The objective of this SBIR program is the modification of a polymeric trileaflet heart valve to a valve prosthesis that can be delivered percutaneously as a transcatheter aortic valve replacement. Key innovations include improved durability and hemodynamic properties, lower manufacturing costs, and simplified delivery over existing transcatheter bioprosthetic v ...
SBIR Phase I 2010 Department of Health and Human ServicesNational Institutes of Health -
Minimally Invasive Pediatric VAD for Treatment of Acute Heart Failure
SBC: ABIOMED, INC. Topic: NHLBIDESCRIPTION (provided by applicant): The overall objective of this proposed program is the commercialization of the Pediatric Impella system, a minimally invasive ventricular assist device (VAD) for treatment of acute heart failure in pediatric patients. The device will be a less traumatic alternative to extracorporeal membrane oxygenation (ECMO), the current standard of care for these patients. T ...
SBIR Phase I 2010 Department of Health and Human ServicesNational Institutes of Health -
High Performance Portable Neutron Detector
SBC: AGILTRON, INC. Topic: 1012A Neutron detection device is an indispensable tool for power, medical, and defense applications. Proliferation of weapons of mass destruction such as nuclear weapons is a serious threat in today's world. Low cost, low power, high performance, rugged and portable neutron detection devices are highly desirable for these applications. Agiltron proposes an unprecedented fabrication and integration ap ...
SBIR Phase I 2010 Department of Homeland Security -
Compact Chemical Sensor for Measurement of Internal Dose of Environmental Agents
SBC: AGILTRON, INC. Topic: NIEHSDESCRIPTION (provided by applicant): Detection of exposure to environmental agents by measurement of internal dose of such agents or their metabolites, chemical or biological, requires rapid assessment and identification of exposure to both known and unknown threats. Fast detection and identification of exposure to such threats can provide prompt warning of the extent and severity of the exposure ...
SBIR Phase I 2010 Department of Health and Human ServicesNational Institutes of Health -
Generation of bivalent aptamers with high affinity and selectivity for detection of viruses and bacteria from environmental samples
SBC: RADIATION MONITORING DEVICES, INC. Topic: HSB091003Better methodologies for the rapid detection of pathogenic bacteria and viruses are needed. A particular problem with current antibody-based assays is cross-reactivity with similar, but harmless, species. Radiation Monitoring Devices, Inc. proposes developing nucleic acid-based affinity reagents (aptamers) against botulinum neurotoxin, as well as against a model pathogenic virus (VSV) and spore (B ...
SBIR Phase II 2010 Department of Homeland Security -
Semiconductor Neutron Detectors
SBC: RADIATION MONITORING DEVICES, INC. Topic: 1012In the proposed program we plan to investigate novel semiconductor neutron detectors based on the wide bandgap, lithium containing compositions LiMgP LiMgAs and LiZnP. The goal of the program is to produce detector quality crystals and to demonstrate efficient thermal neutron detection, with the possibility of providing neutron gamma discrimination. We will examine the synthesis and purification o ...
SBIR Phase I 2010 Department of Homeland Security -
New Wide Bandgap Semiconductor Materials for Neutron Detection
SBC: RADIATION MONITORING DEVICES, INC. Topic: 1012In the proposed program, we plan to investigate novel semiconductor neutron detectors based on the wide bandgap lithium containing compositions LiGaSe2, LiGaTe2, LiInS2, and LiInSe2. The goal of the program is to produce detector quality crystals and to demonstrate efficient thermal neutron detection, with the possibility of providing neutron gamma discrimination. We will examine the synthesis and ...
SBIR Phase I 2010 Department of Homeland Security -
New Scintillator for Neutron Detection
SBC: RADIATION MONITORING DEVICES, INC. Topic: 1012Neutron detection is one of the methods used in revealing illicit nuclear materials. Currently, there is an ongoing search for new and better neutron detectors prompted by anticipated shortages of He-3 that is used in many of the current detection systems. This effort proposes and investigation and development of a new thermal neutron and gamma scintillator. The scintillator belongs to already pro ...
SBIR Phase I 2010 Department of Homeland Security -
Low Cost, Large Volume 3He Replacement Neutron Detector
SBC: RADIATION MONITORING DEVICES, INC. Topic: 1012Nuclear instrumentation for the detection of thermal neutrons relies heavily upon 3He because of its desirable nuclear properties and physical characteristics. The decline in production combined with increased demand has depleted the 3He stockpile and the supply of 3He is presently insufficient for US needs. The proposed effort seeks to address this problem by developing detector technology to hel ...
SBIR Phase I 2010 Department of Homeland Security