You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. Silicon Receiver for Millimeter Wave Distributed Aperture Imager with Optical Upconversion

    SBC: PHASE SENSITIVE INNOVATIONS INC            Topic: SB113003

    In this Phase II SBIR effort we will dramatically reduce the size, weight, and power requirements of a passive millimeter wave imaging system based on optical upconversion. To this end, we will integrate custom silicon-germanium low noise amplifiers that have been designed to efficiently couple with our high performance lithium niobate upconversion modules. In Phase I we analyzed the design requ ...

    SBIR Phase II 2012 Department of DefenseDefense Advanced Research Projects Agency
  2. Anion Exchange Resin for Chirality-based Separation of Single-wall Carbon Nanotubes

    SBC: Sepax Technologies, Inc.            Topic: N/A

    Sepax Technologies, Inc. has identified a new type of anoin-exchange resin which separates single-wall carbon nanotubes (SWCNTs) with >80% recovery yield and resolves in a single pass the chiral tubes of (6,5) well from commercial SWCNT starting materials by Chromatography. Improvement and scale up of the targeted resin production will facilitate the separation of chiral nanotubes for the academic ...

    SBIR Phase II 2012 Department of CommerceNational Institute of Standards and Technology
  3. Anomaly Detection At Multiple Scales (ADAMS)

    SBC: Allure Security Technology            Topic: SB111003

    We propose to develop robust technical capabilities (resulting in commercial-quality software product) for identifying likely malicious as well as overly trusting insiders within an organization by leveraging automatically generated misinformation. Our system will work in conjunction with modern system and network monitoring technologies such as Data Leakage Prevention (DLP) systems and honeypots ...

    SBIR Phase II 2012 Department of DefenseDefense Advanced Research Projects Agency
  4. Design of Acoustic Metamaterials for Passive Hearing Protector

    SBC: CFD RESEARCH CORPORATION            Topic: SB103006

    We propose to develop new acoustic metamaterials (AMMs) using locally resonant regimented structures, suitable for application in Hearing Protector Devices (HPDs), that will act as frequency selective acoustic filter for hearing protection. Our computational simulations conducted in phase I project have demonstrated that significant acoustic attenuation can be achieved in desired frequency ranges ...

    SBIR Phase II 2012 Department of DefenseDefense Advanced Research Projects Agency
  5. Revolutionary Advances in Large-Scale Manufacturing in Quantities of One

    SBC: Step Tools, Inc.            Topic: SB102005

    We propose to build a National Simulation Service that will have triple benefits to industry. First, it will give companies new freedom to produce at a scale that matches demand. Second, companies will have access to a wider variety of expertise and options than they would otherwise have internally, resulting in better products and processes. Third, it will make companies more robust because the ...

    SBIR Phase II 2012 Department of DefenseDefense Advanced Research Projects Agency
  6. A Cognitive Capture System for Modeling and Tracking Neural Synchrony

    SBC: Neuromatters LLC            Topic: OSD10HS3

    There is at present a lack of portable, practical and non-invasive sensing platforms to: a. understand, detect and present neural events triggered by narratives; b. to derive cognitive interpretations of a story and link them to semantic interpretations, the story"s function and/or the storyteller"s intent. Based on the Phase I design of a system, termed"Cognitive Capture", to enable the unobtrusi ...

    SBIR Phase II 2012 Department of DefenseDefense Advanced Research Projects Agency
  7. Super-Resolution Magnetic Field Microscopy [SRMFM] Using Multifunctional Diamond Nanosensors

    SBC: DUST IDENTITY, INC.            Topic: SB122002

    In this program, we will develop and prototype a new Super-Resolution Magnetic Field Microscopy (SRMFM) system that employs nitrogen-vacancy (NV) centers in diamond nanostructures to image magnetic fields with a sensitivity below 100nT/ & #8730;Hz and a spatial resolution better than 20 nm. The system consists of two primary components: (1) hardware and software for NV electron spin-based imaging ...

    SBIR Phase I 2012 Department of DefenseDefense Advanced Research Projects Agency
  8. PNA-Based Rapidly Adaptable Anti-Microbial Nanoparticles

    SBC: AGAVE BIOSYSTEMS INC.            Topic: SB121003

    Agave BioSystems proposed to develop a system of Rapidly Adaptable Nanotherapeutics (RANT) by combining advanced bioformatics, with DNA-based nanoparticles, peptide nucleic acid (PNA) antisense oligonucleotides, and cell permeating peptides (CPPs). Advanced bioinformatics computing will allow for the identification of essential and drug resistance genes within the target pathogens. These genes w ...

    SBIR Phase I 2012 Department of DefenseDefense Advanced Research Projects Agency
  9. Biometrics-at-a-distance

    SBC: VAWD APPLIED SCIENCE & TECHNOLOGY CORP            Topic: SB121004

    VAWD Applied Science and Technology is pleased to offer the following proposal in response to DARPA"s Small Business Initiative SB121-004, Biometrics-at-a-Distance. VAWD"s experience with development and testing of stand-off range Sense-Through-the-Wall (STTW) and Foliage Penetration (FOPEN) radars for detection and tracking of human motion in last five years enable VAWD to propose the following ...

    SBIR Phase I 2012 Department of DefenseDefense Advanced Research Projects Agency
  10. Improved Microcalorimeter Detectors for X-Ray Chemical Shift Mapping

    SBC: STAR CRYOELECTRONICS, LLC            Topic: N/A

    X-ray fluorescence spectroscopy is a widely used and extremely sensitive analytical technique for qualitative as well as quantitative chemical analysis. Superconducting Transition Edge Sensor (TES) microcalorimeter detectors have now been developed that achieve an energy resolution of 2 eV (full width at half maximum) for 1.5 keV X-rays, which is sufficient to enable the measurement of the small s ...

    SBIR Phase I 2012 Department of CommerceNational Institute of Standards and Technology
US Flag An Official Website of the United States Government