You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. Development of an EO/IR Common Aperture Modular Multifunction Sensor

    SBC: ULTIMARA INC            Topic: N11AT024

    The goal of this program is to develop and fabricate an ultra-low Size, Weight, and Power (SWAP) integrated electro-optic beam-steering technology that utilizes ultra-fast electro-optic active plasmonic waveguide arrays to achieve very wide scanning angle with diffraction limited beam quality. We develop a very scalable electro-optic plasmonic waveguides array that provides the electro-optic pha ...

    STTR Phase II 2013 Department of DefenseNavy
  2. rAAV5-hCNGB3 Gene Therapy for Achromatopsia: Safety and Efficacy in a Dog Model

    SBC: APPLIED GENETIC TECHNOLOGIES CORPORATION            Topic: N

    DESCRIPTION provided by applicant Complete achromatopsia is an autosomal recessive inherited congenital disorder of retinal cone photoreceptors Patients with complete achromatopsia experience extreme light sensitivity and daytime blindness and best visual acuity under non bright light conditions is usually or worse and generally stable over time In addition to poor acuity hypersensit ...

    STTR Phase I 2013 Department of Health and Human ServicesNational Institutes of Health
  3. Visible Electro-Optical (EO) System and LIDAR Fusion for Low Cost Perception by Autonomous Ground Vehicles

    SBC: TOYON RESEARCH CORPORATION            Topic: N11AT020

    The Toyon-MST team proposes to perform research and development of a system which fuses multi-spectral EO and 3D data collected with a low-cost LIDAR to enable improved perception for unmanned ground vehicles (UGVs). The scope of the proposed work includes development of algorithms and software, and development, implementation, integration, testing, and delivery of a prototype, to perform EO-LIDAR ...

    STTR Phase II 2013 Department of DefenseNavy
  4. Planar Doppler Velocimetry for Aircraft Exhausts

    SBC: METROLASER, INCORPORATED            Topic: N11AT004

    A diagnostic is being developed for aircraft engine exhausts that measures three velocity components in a slice through the plume. The method measures the Doppler shift of laser light scattered from particles naturally present in the flow, such as soot or dust. Two key areas of uncertainty were investigated in the Phase I study: 1) scattered light intensity from soot particles of sizes and concent ...

    STTR Phase II 2013 Department of DefenseNavy
  5. Wireless Torque Sensor for Condition Based Maintenance

    SBC: Albido Corporation            Topic: N11AT030

    In recent years, the need for highly reliable, durable and non-intrusive systems for monitoring the health condition of naval structures becomes more and more recognized. Of particular importance is the condition based maintenance of Navy rotating machinery (motors, generators, pumps, gear systems, etc.). Such Structural Health Monitoring (SHM) systems should be able to detect failures in their ea ...

    STTR Phase II 2013 Department of DefenseNavy
  6. Development of OCT Imaging Adapter for Interstitial Tissue Imaging

    SBC: WEST FACE MEDICAL DEVICES, INC.            Topic: NIBIB

    DESCRIPTION provided by applicant This Phase I STTR Grant Proposal requests $ support for WestFace Medical Device to construct and test the WestFace Imaging Adaptor in conjunction with Ruikang K Wang PhD and his laboratory at the University of Washington Utilizing optical coherence tomography OCT the patented OCT Adaptor USPTO Pats provides r ...

    STTR Phase I 2013 Department of Health and Human ServicesNational Institutes of Health
  7. Motion Imagery Exploitation with Compressive Sensing for Wide-Area Surveillance

    SBC: MAYACHITRA, INC.            Topic: N12AT026

    technical abstract

    STTR Phase II 2013 Department of DefenseNavy
  8. Modeling of pulse propagation in a four level atomic medium for gyroscopic measurements

    SBC: ROCHESTER SCIENTIFIC LLC            Topic: N11AT005

    We propose to continue the development of software designed to model the propagation of light pulses through atomic media by including the capability to model propagation in optical cavities with active laser media, among other improvements. The software will be used to design and analyze a gyroscope based on the Sagnac effect that achieves enhanced sensitivity by employing a highly dispersive ato ...

    STTR Phase II 2013 Department of DefenseNavy
  9. Synergistic MIMO Radar and Data Adaptive Signal Processing Experimentation

    SBC: INTEGRATED ADAPTIVE APPLICATIONS, INC            Topic: N11AT002

    The proposed work seeks to clearly demonstrate the advantage of the multiple-input multiple-output (MIMO) radar architecture over a similar single-input multiple-output (SIMO) or phased array system; the benefit of applying data-adaptive signal processing techniques in favor of their data-independent counterparts; and the utility of transmitting advanced probing waveforms as opposed to conventiona ...

    STTR Phase II 2013 Department of DefenseNavy
  10. Compact, Light Weight, Low Cost, Precision, Non-inertial Underwater Navigation Sensor

    SBC: ANALYSIS DESIGN & DIAGNOSTICS INC            Topic: N11AT027

    TBD

    STTR Phase II 2013 Department of DefenseNavy
US Flag An Official Website of the United States Government