You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. Fully Encapsulating Dielectrics for Gaseous Helium Cooled Superconducting Power Cables

    SBC: ADVANCED CONDUCTOR TECHNOLOGIES LLC            Topic: N16AT011

    The proposed program will develop dielectrics for dc superconducting power transmission cables that are cooled with cryogenic helium gas. The Dielectrics will be sealed again helium gas penetration and allow for an operating voltage of 12 kV in a pressure of 2 MPa at 50 K. The dielectrics will be designed for use with all helium facing components of power transmission systems based on CORC cables. ...

    STTR Phase II 2018 Department of DefenseNavy
  2. Simultaneous Multiple Object Detection System

    SBC: Semquest, Inc.            Topic: MDA16T006

    An advanced hit detection technology is needed for MDA that can report impacts at hyper-velocities and at multiple hit locations. We present a technology with a high level of performance that leverages decades of hit technology experience and utilizes existing technologies developed under previous efforts. Our technology offers a low latency non-interpolated direct indicator of multiple hit locati ...

    STTR Phase II 2018 Department of DefenseMissile Defense Agency
  3. Integrated Computational Material Engineering Approach to Additive Manufacturing for Stainless Steel (316L)

    SBC: SENVOL LLC            Topic: N16AT022

    The objective in this project is to implement and validate a probabilistic qualification framework that will enable additive manufacturing (AM) materials and part qualification through the use of a data-driven predictive model within a statistical framework. Senvol seeks to develop and validate a data-driven ICME probabilistic framework for assisting qualification of AM materials and parts. Phase ...

    STTR Phase II 2018 Department of DefenseNavy
  4. A Scalable Event Extractor for Multi-Level Event Data and Pattern Archiving: SEE

    SBC: Intelligent Automation, Inc.            Topic: N17AT022

    To address the need of auto-extracting data relevant to significant events and to archive patterns, Intelligent Automation, Inc. (IAI) team proposes to continue developing a Scalable Event Extractor for Multi-Level Event Data and Pattern Archiving: SEE. The key innovations of our proposed SEE system are (1) a large class of analytics that extract valuable and important information from raw data, a ...

    STTR Phase II 2018 Department of DefenseNavy
  5. Energy Efficient, Non-Silicon Digital Signal Processing (DSP)

    SBC: HYPRES INC            Topic: N17AT027

    Superconductor digital circuits, operating at very high clock speed, can directly process wideband digitized radio frequency (RF) signals. By integrating such digital processing circuitry together with superconductor analog-to-digital converters (ADCs), we propose to develop the next generation digital-RF receivers. Leveraging the recent development of multiple superconductor ADCs on the same chip ...

    STTR Phase II 2018 Department of DefenseNavy
  6. Validation of a salivary miRNA diagnostic test for autism spectrum disorder

    SBC: Quadrant Biosciences Inc.            Topic: 103

    Autism spectrum disorder (ASD) is a continuum of neurodevelopmental characteristics that includes deficits in communication and social interaction, as well as restrictive, repetitive interests and behaviors. ASD is an increasing public health concern, with about 1 in 45 American children diagnosed with ASD in 2014, a 10-fold increase in prevalence over the past 40 years. The effect of ASD on both ...

    STTR Phase II 2018 Department of Health and Human ServicesNational Institutes of Health
  7. Optimized High Performance Stainless Steel Powder for Selective Laser Melting Additive Manufacturing (AM)

    SBC: SHEPRA, INC.            Topic: N16AT007

    Stainless steel is a vital component of many air, land and sea systems that support the Navy warfighter. In particular, 17-4 precipitation hardened stainless steel, (17-4 PH SS) with its extrodinary combination of strength, ductility, high temperature performance and corrosion resistance plays an important role in supporting the warfighter. When processed conventionally, 17-4 PH SS typical exhibit ...

    STTR Phase II 2018 Department of DefenseNavy
  8. Quantifying Uncertainty in the Mechanical Performance of Additively Manufactured Parts Due to Material and Process Variation

    SBC: MRL MATERIALS RESOURCES LLC            Topic: N16AT004

    Additive manufacturing is an extremely customizable process; however, variations in the chosen build parameters can lead to drastic differences in part performance. The performance variation due to process parameters is still not well understood, and propagating all uncertainties from the various sources has been a challenge. Sources of AM parts’ performance variability include uncertainties in ...

    STTR Phase II 2018 Department of DefenseNavy
  9. Cuff Electrodes with Soft Wire Electrical Leads

    SBC: TDA RESEARCH, INC.            Topic: 102

    Project Summary AbstractDevelopment of a Nerve Cuff Electrode from Soft and Elastomeric Conducting Wires STTR Phase I ApplicationPIBrady ClapsaddleTDA ResearchIncBio electronic interfaces are used in a wide array of applications for recording and providing electrical impulses to treat diseaseOne common interface device for the PNS is the cuff electrodeCurrent cuff electrodes have many failure mode ...

    STTR Phase I 2018 Department of Health and Human ServicesNational Institutes of Health
  10. Principled Design of an Augmented Reality Trainer for Medics

    SBC: UNVEIL LLC            Topic: DHP17A003

    Augmented reality (AR) offers the ability to enhance existing combat medic training by including perceptual cues and adaptive training elements to traditional simulation-based training using manikins. Unveil has developed a training system called the Macrocognitive AR Trainer (MART). MART is designed to foster the development of macrocognitive skills (e.g., sensemaking, assessment skills, mental m ...

    STTR Phase II 2018 Department of DefenseDefense Health Agency
US Flag An Official Website of the United States Government