You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. Human Performance Optimization

    SBC: HVMN Inc.            Topic: SOCOM17C001

    During altitude-induced hypoxia, operator cognitive and physical capacity degrades, compromising individual and team performance. Cognitive degradation is linked to falling brain energy levels, increased reliance on anaerobic energy production and lactate accumulation. Ketones are the evolutionary alternative substrate to glucose for brain metabolic requirements; previous studies demonstrated that ...

    STTR Phase II 2019 Department of DefenseSpecial Operations Command
  2. Human Performance Optimization

    SBC: REJUVENATE BIO INC            Topic: SOCOM17C001

    Special OperationsForces (SOF)are an integral aspect of the US military. SOF operators are among the most elite and highly qualified individuals in the U.S.military. As such, extraordinary physical and mental demands are placed upon them to excel in extreme environments for extended periods of time. This unrelenting cycle of combat deployments and intense pre-deployment training shortens the funct ...

    STTR Phase II 2019 Department of DefenseSpecial Operations Command
  3. Principled Design of an Augmented Reality Trainer for Medics

    SBC: UNVEIL LLC            Topic: DHP17A003

    Augmented reality (AR) offers the ability to enhance existing combat medic training by including perceptual cues and adaptive training elements to traditional simulation-based training using manikins. Unveil has developed a training system called the Macrocognitive AR Trainer (MART). MART is designed to foster the development of macrocognitive skills (e.g., sensemaking, assessment skills, mental m ...

    STTR Phase II 2018 Department of DefenseDefense Health Agency
  4. Integrated system for field, clinic and laboratory preparation of biological specimens for microscopy

    SBC: Microscopy Innovations, LLC            Topic: DHP16C004

    Biological tissues collection is problematic and risky even under ideal conditions; when collection occurs in remote locations, or by minimally- trained personnel, as may occur in response to an emerging disease threat, risks are magnified. This proposal addresses this issue by developing a Field Fixation Unit (FFU) for specimen collection that utilizes single-use capsules pre-loaded with fixative ...

    STTR Phase II 2018 Department of DefenseDefense Health Agency
  5. Small Team Command, Control, Communications and Situational Awareness (C3SA), SOCOM08-001

    SBC: CEEBUS TECHNOLOGIES, LLC            Topic: SOCOM08001

    SOF combat swimmers have a need for the continuous monitoring of each others relative position while diving and for the capability of being able to communicate with each other to help establish a common operational picture (COP).The C3SA system was previously developed under SBIR Topic SOCOM08-001 thru the receipt of both Phase I and Phase II SBIR awards.The C3SA established a stand-alone network ...

    STTR Phase II 2018 Department of DefenseSpecial Operations Command
  6. Multi-Functional Nanotube-Based Sensor Array for Detecting Blood Coagulation Defects

    SBC: INNOSENSE CORPORATION            Topic: DHA19A001

    Defense Health Agency (DHA) is seeking a multi-functional diagnostic to determine blood coagulopathy in real time at point-of-care (POC). Blood coagulopathy, resulting in uncontrolled bleeding, is implicated in 80% of operating room deaths and 50% of trau

    STTR Phase I 2019 Department of DefenseDefense Health Agency
  7. Cervical Spine Health Improvement Products

    SBC: SWITCHBOX INC            Topic: DHA18B001

    Most standard-of-care tools and techniques for evaluating neck disorders are subjective, unreliable, and do not provide actionable information for providers, payers, and organizations to deliver efficient and effective care. This lack of objective neck he

    STTR Phase I 2019 Department of DefenseDefense Health Agency
  8. Human Performance Optimization: Ketone Esters for Optimization of Operator Performance in Hypoxia

    SBC: HVMN Inc.            Topic: SOCOM17C001

    In the setting of altitude-induced hypoxia, operator cognitive capacity degrades and can compromise both individual and team performance. This degradation is linked to falling brain energy (ATP) levels and an increased reliance on anaerobic energy production from glucose. Ketone bodies are the evolutionary alternative substrate to glucose for brain metabolic requirements; previous studies have sho ...

    STTR Phase I 2018 Department of DefenseSpecial Operations Command
  9. Inhibiting Prolyl Hydroxylase to Mimic Natural Acclimatization to High Altitude to Improve Warfighter Performance at High Altitude

    SBC: Research Logistics Company            Topic: SOCOM17C001

    Acclimatization is the long-term adjustment that humans experience when exposed for weeks or months to high altitude. Acclimatization is important in this context because a warfighter who is acclimatized to high altitude is immune to high altitude illness, has superior work capacity, and has cognitive function approaching that found at sea level. In other words, the acclimatized warfighter is opti ...

    STTR Phase I 2018 Department of DefenseSpecial Operations Command
  10. Oxygen Production and Delivery on Demand

    SBC: GLOBAL RESEARCH & DEVELOPMENT INC            Topic: DHA17B005

    This proposal is in response to the Defense Health Agency 2017 Phase I SBIR topic 17B-005.The approach is the use of a membrane oxygen pump using newly developed nano-thickness membranes with all the layers less than 1 micron total.Nanometer thickness membranes enable more oxygen output per surface area at temperatures of 300-600 C than current state-of-the -art 600-800 C membranes that are 50-300 ...

    STTR Phase I 2018 Department of DefenseDefense Health Agency
US Flag An Official Website of the United States Government