You are here
Award Data
The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.
Download all SBIR.gov award data either with award abstracts (290MB)
or without award abstracts (65MB).
A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.
The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.
-
Reduced-Order High-Fidelity Models for Signature Propagation/WAVE
SBC: AVID LLC Topic: A07T028We propose to develop variable fidelity acoustic propagation models and combine them with GIS, optimization, and visualization software in order to create site-specific real-time decision aid tools for optimal sensor placement. High fidelity finite-differ
STTR Phase II 2010 Department of DefenseArmy -
MEMS based thermopile infrared detector array for chemical and biological sensing
SBC: BFE Acquisition Sub II, LLC Topic: A10AT004Thermopile arrays manufactured using integrated process compatible materials and micro-machining will provide high performance with low manufacturing cost. Black Forest Engineering (BFE) teamed with Case Western Reserve University will design thermopiles using silicon based semiconductors and compare performance. Low cost thermopiles, differentially coupled with advanced BFE CMOS readout, will pr ...
STTR Phase I 2010 Department of DefenseArmy -
An Automated, High Throughput, Filter-Free Pathogen Preconcentrator
SBC: CFD RESEARCH CORPORATION Topic: A10AT016Accurate real-time waterborne pathogen detection is of paramount importance to security of U.S. military forces and installations. Fieldable high-throughput pathogen concentration is a critical analytical need for enhanced detection performance. Existing concentration methods are time-consuming, bulky, labor-intensive, power- and reagent-hungry, and consequently ill-suited for battlefield deployme ...
STTR Phase I 2010 Department of DefenseArmy -
Passive Infrared Detection of Aerosolized Bacterial Spores
SBC: DECIBEL RESEARCH, INC. Topic: A10AT019deciBel Research and our university partner, Rochester Institute of Technology (RIT)-Center for Imaging Science, propose to develop a dual MWIR/LWIR imaging polarimeter for the detection and discrimination of aerosolized biological spores. The system will exploit spectral absorption and MIE scattering-induced radiometric and polarimetric phenomenon exhibited by clouds of aerosolized biological spo ...
STTR Phase I 2010 Department of DefenseArmy -
Topological Data Analysis and Wide Area Detection of Chemical and Biological Contamination
SBC: FOLDED STRUCTURES COMPANY LLC Topic: A10AT020Topological data analysis is a new mathematical method used to study these massive data sets that arise in a variety of situations including military operations and national security. The use of passive infrared sensors for a wide area detection system involving chemical and biological contaminants produces massive amounts of hyperspectral image data. Recent research in this area include fast al ...
STTR Phase I 2010 Department of DefenseArmy -
Dilution refrigerator technology for scalable quantum computing
SBC: High Precision Devices, Inc. Topic: ARMY08T020Currently large capacity cryostats, capable of hosting experiments for many qubits, require expensive and hard to obtain liquid cryogens. A few small cryo-free systems exist but they are non-ideal for this use. An opportunity exists for a large scale, c
STTR Phase II 2010 Department of DefenseArmy -
Narrowband microbolometer arrays for infrared chemical sensing
SBC: ITN ENERGY SYSTEMS, INC. Topic: A10AT023This Small Business Technology Transfer Research program will develop narrow band plasmonic resonant cavity filters with integrated microbolometer sensors operating in the long wave infrared (LWIR) atmospheric transmission band for IR absorption measurements of low concentration chemicals. IR spectroscopy can identify a wide range of contaminants, including chemical/biological warfare agents, exp ...
STTR Phase I 2010 Department of DefenseArmy -
DIPAIN based assay for the T-2 Toxin
SBC: L. C. PEGASUS CORP. Topic: A10AT021This proposed project is to develop a rapid assay for T-2 Toxin. Under this project we will develop DIPAIN-derivative based test-strips that indicate the presence of trace quantities of trichothecene mycotoxins in aqueous solutions. The T-2 toxin will be used as a test case for this effort. We will use of 2-(diphenylacetyl)-l,3-indanedione-l-hydrazone (DIPAIN II) and its derivatives as reagents o ...
STTR Phase I 2010 Department of DefenseArmy -
Decontamination storage bags for chemical and biological warfare agents
SBC: MATERIALS MODIFICATIONS INC Topic: A10AT003This STTR Phase I project will develop a novel toxic material storage bag with an inner liner capable of decontaminating chemical and biological warfare agents (CBWA’s).. The inner-liner technology would entail adsorption and decomposition of warfare agents without the release of toxic agents, and will result in a storage bag capable of being disposed of in an environmentally safe fashion. The ...
STTR Phase I 2010 Department of DefenseArmy -
Advanced Vehicle/Terrain Interaction Modeling to Support Power and Energy Analysis
SBC: MECHANICAL SIMULATION INTERNATIONAL Topic: ARMY08T042The development of advanced, realtime, operator-in-the-loop tire/track/soil models, which can predict power and energy requirements, is an essential requirement for determining operational profiles for vehicles, especially hybrids, during the design and d
STTR Phase II 2010 Department of DefenseArmy