  1. MEMS based thermopile infrared detector array for chemical and biological sensing

    SBC: BFE Acquisition Sub II, LLC            Topic: A10AT004

    Thermopile arrays manufactured using integrated process compatible materials and micro-machining will provide high performance with low manufacturing cost. Black Forest Engineering (BFE) teamed with Case Western Reserve University will design thermopiles using silicon based semiconductors and compare performance. Low cost thermopiles, differentially coupled with advanced BFE CMOS readout, will pr ...

    STTR Phase I 2010 Department of DefenseArmy
  2. An Automated, High Throughput, Filter-Free Pathogen Preconcentrator

    SBC: CFD Research Corporation            Topic: A10AT016

    Accurate real-time waterborne pathogen detection is of paramount importance to security of U.S. military forces and installations. Fieldable high-throughput pathogen concentration is a critical analytical need for enhanced detection performance. Existing concentration methods are time-consuming, bulky, labor-intensive, power- and reagent-hungry, and consequently ill-suited for battlefield deployme ...

    STTR Phase I 2010 Department of DefenseArmy
  3. Passive Infrared Detection of Aerosolized Bacterial Spores

    SBC: Decibel Research, Inc.            Topic: A10AT019

    deciBel Research and our university partner, Rochester Institute of Technology (RIT)-Center for Imaging Science, propose to develop a dual MWIR/LWIR imaging polarimeter for the detection and discrimination of aerosolized biological spores. The system will exploit spectral absorption and MIE scattering-induced radiometric and polarimetric phenomenon exhibited by clouds of aerosolized biological spo ...

    STTR Phase I 2010 Department of DefenseArmy
  4. Dilution refrigerator technology for scalable quantum computing

    SBC: High Precision Devices, Inc.            Topic: ARMY08T020

    Currently large capacity cryostats, capable of hosting experiments for many qubits, require expensive and hard to obtain liquid cryogens. A few small cryo-free systems exist but they are non-ideal for this use. An opportunity exists for a large scale, c

    STTR Phase II 2010 Department of DefenseArmy
  5. Narrowband microbolometer arrays for infrared chemical sensing

    SBC: ITN ENERGY SYSTEMS, INC.            Topic: A10AT023

    This Small Business Technology Transfer Research program will develop narrow band plasmonic resonant cavity filters with integrated microbolometer sensors operating in the long wave infrared (LWIR) atmospheric transmission band for IR absorption measurements of low concentration chemicals. IR spectroscopy can identify a wide range of contaminants, including chemical/biological warfare agents, exp ...

    STTR Phase I 2010 Department of DefenseArmy
  6. Bimetallic Nanoparticle Catalysts for Reforming of Logistics Fuels

    SBC: NanoScale Materials, Inc.            Topic: A09AT018

    High efficiency, low pollution, and long lifetime make hydrogen-powered fuel cells desirable for portable power generation by the Army. However, it is impractical to transport hydrogen to where it is needed. Instead, reforming a transportable liquid fuel such as JP-8 or diesel fuel can produce the hydrogen for the fuel cell. Noble metal catalysts can speed this reforming, but they are expensive a ...

    STTR Phase I 2010 Department of DefenseArmy
  7. Chemical-Biological Forensic Evidence Container with Agent and Tamper Resistant Tools

    SBC: NanoScale Materials, Inc.            Topic: A10AT003

    The proposed research incorporates several inventions to produce structural components that can be assembled into a highly enhanced chemical-biological (CB) forensic evidence container for transport and storage of contaminated articles. Bio-hazardous materials are frequently encountered in standard investigations, and currently used evidence bags are designed to handle the containment and preserv ...

    STTR Phase I 2010 Department of DefenseArmy
  8. High Surface-Area Metal Oxide Sorbent for Sampling and Infrared Detection of Water Contaminants

    SBC: NanoScale Materials, Inc.            Topic: A10AT018

    Detection and identification of toxic chemical in water is vital for various military, environmental, and industrial applications. Specifically, the Joint Services have a need for rapid detection of trace levels of chemical contamination in water systems. This Small Business Technology Transfer Phase I project will focus on the development of a novel detection system for sampling and identificat ...

    STTR Phase I 2010 Department of DefenseArmy
  9. Eye-safe Optically-Pumped Gas-filled Fiber Lasers

    SBC: Precision Photonics Corporation            Topic: ARMY08T021

    An eye-safe optically pumped laser based on a gas-filled hollow optical fiber will be demonstrated to lase at both near infrared (IR) and mid IR wavelengths. These lasers will be the first in a new class of IR lasers, based on the combination of hollow-f

    STTR Phase II 2010 Department of DefenseArmy
  10. Impact of Climate Change on Military Compounds in the Environment

    SBC: Environmental Quality Management            Topic: A09AT024

    This will facilitate the development of remedial approaches for existing facilities and assist in planning new facilities, logistics, and procedures to protect the environment without impairing critical mission functionality. The commercial application will include software distribution and updates.

    STTR Phase I 2010 Department of DefenseArmy
US Flag An Official Website of the United States Government