You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. MEMS based thermopile infrared detector array for chemical and biological sensing

    SBC: BFE Acquisition Sub II, LLC            Topic: A10AT004

    Thermopile arrays manufactured using integrated process compatible materials and micro-machining will provide high performance with low manufacturing cost. Black Forest Engineering (BFE) teamed with Case Western Reserve University will design thermopiles using silicon based semiconductors and compare performance. Low cost thermopiles, differentially coupled with advanced BFE CMOS readout, will pr ...

    STTR Phase I 2010 Department of DefenseArmy
  2. An Automated, High Throughput, Filter-Free Pathogen Preconcentrator

    SBC: CFD RESEARCH CORPORATION            Topic: A10AT016

    Accurate real-time waterborne pathogen detection is of paramount importance to security of U.S. military forces and installations. Fieldable high-throughput pathogen concentration is a critical analytical need for enhanced detection performance. Existing concentration methods are time-consuming, bulky, labor-intensive, power- and reagent-hungry, and consequently ill-suited for battlefield deployme ...

    STTR Phase I 2010 Department of DefenseArmy
  3. Passive Infrared Detection of Aerosolized Bacterial Spores

    SBC: DECIBEL RESEARCH, INC.            Topic: A10AT019

    deciBel Research and our university partner, Rochester Institute of Technology (RIT)-Center for Imaging Science, propose to develop a dual MWIR/LWIR imaging polarimeter for the detection and discrimination of aerosolized biological spores. The system will exploit spectral absorption and MIE scattering-induced radiometric and polarimetric phenomenon exhibited by clouds of aerosolized biological spo ...

    STTR Phase I 2010 Department of DefenseArmy
  4. Narrowband microbolometer arrays for infrared chemical sensing

    SBC: ITN ENERGY SYSTEMS, INC.            Topic: A10AT023

    This Small Business Technology Transfer Research program will develop narrow band plasmonic resonant cavity filters with integrated microbolometer sensors operating in the long wave infrared (LWIR) atmospheric transmission band for IR absorption measurements of low concentration chemicals. IR spectroscopy can identify a wide range of contaminants, including chemical/biological warfare agents, exp ...

    STTR Phase I 2010 Department of DefenseArmy
  5. Random Number Generation for High Performance Computing

    SBC: Silicon Informatics, Inc.            Topic: A10AT012

    Highly scalable parallel random number generators (RNGs) will be developed, evaluated and implemented for use in high performance computing on thousands of multi-core processors and general purpose graphics processing units. The main contributions are: (a) design and implementation of new parallel test methods that capture the inter-stream correlations exhibited in practice and complement the curr ...

    STTR Phase I 2010 Department of DefenseArmy
  6. Impact of Climate Change on Military Compounds in the Environment

    SBC: Environmental Quality Management            Topic: A09AT024

    This will facilitate the development of remedial approaches for existing facilities and assist in planning new facilities, logistics, and procedures to protect the environment without impairing critical mission functionality. The commercial application will include software distribution and updates.

    STTR Phase I 2010 Department of DefenseArmy
  7. Plasmonic MEMS Sensor Array

    SBC: Five Stones Research Corporation            Topic: A10AT002

    Sensor development researchers and engineers have perpetually sought novel methods to reduce sensor size and improve performance. Continued miniaturization of sensors through micromachining has enabled novel applications and introduced new paradigms for engineered systems to interact with the world. The challenge has always been to improve performance while continually reducing size. In the cur ...

    STTR Phase I 2010 Department of DefenseArmy
  8. AUTOMATED SYSTEM FOR DETERMINATION OF JP-8 SMOKE POINT AND LUMINOMETER NUMBER

    SBC: Engineering And Scientific Innovations Inc.            Topic: A10AT010

    Engineering & Scientific Innovations, Inc. (ESI) in cooperation with University of Cincinnati (UC) will develop an automated, standalone radiative heat and smoke point measurement device that provides improved accuracy and removes much of the subjectivity of the current method (ASTM D1322) by incorporating more modern and automated equipment. The proposed system utilizes a standard, laminar dif ...

    STTR Phase I 2011 Department of DefenseArmy
  9. Matched Filter Chaos Communications

    SBC: Torch Technologies, Inc.            Topic: A11aT002

    A plan is presented to demonstrate the feasibility and practicality of a radio-frequency Hayes-Corron (H-C) chaos-based communication system employing an optimal spread-spectrum chaotic communication theory to achieve superior low-power, low-probability of interception, multiple-user access, and portability goals. By integrating three concepts: 1) chaotic spreading sequence generation, 2) Hayes en ...

    STTR Phase I 2011 Department of DefenseArmy
  10. Matched Filter Chaos Communications

    SBC: Scieval LLC            Topic: A11aT002

    The use of chaotic hybrid systems has been recently demonstrated in for potential noise-resilient matched-filter communications. A first demonstration at low (audio) frequencies using a combination of analog and digital components has been demonstrated. With this proposal, our objective is to devise a"chaos-on-a-chip"system that can exhibit similar features to those in while operating in the range ...

    STTR Phase I 2011 Department of DefenseArmy
US Flag An Official Website of the United States Government