You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY23 is not expected to be complete until September, 2024.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. Speed-Accuracy Measures for Distributed Interactive Simulation of Nuclear Weapons Effects

    SBC: Pacific-sierra Research Corp.            Topic: N/A

    Using distributed interactive simulation (DIS) to conduct effective training, analyses, or mission support in a tactical nuclear weapons effects (NWE) environment requires realistic computer generated forces (CGF) that are sensitive to such effects. This level of sensitivity requires CGF to apply valid and reliable speed-accuracy measures of environmental effects on human performance within the D ...

    SBIR Phase I 1997 Department of DefenseDefense Threat Reduction Agency
  2. EMP AND HPM SUPPRESSION TECHNIQUES

    SBC: Integrated Sciences            Topic: N/A

    Survival of present day microelectronic circuits depends on their protection from self generated and external electromagnetic interference. This proposal is oriented toward the class of interference generally referred to as overvoltage transients. Means for mitigating these transients include gas discharge tubes, and various solid state devices. Each of these has their own advantages in particu ...

    SBIR Phase I 1996 Department of DefenseDefense Threat Reduction Agency
  3. LONGWAVE ELECTROMAGNETIC SENSOR FOR COUNTERPROLIFERATION ACTIVITIES

    SBC: Pacific-sierra Research Corp.            Topic: N/A

    We propose to design a compact, multiple purpose electromagnetic sensor for monitoring the extremely low frequency (ELF), very low frequency (VLF), and low frequency (LF) spectrum. Our goal is to design a modular, low cost sensor capable of being configured for multiple applications and capable of being employed in remote, unattended sensor networks. We describe three applications or scenarios t ...

    SBIR Phase I 1996 Department of DefenseDefense Threat Reduction Agency
  4. Development of a Two Reference Beam Holographic Technique to Measure the Density Distribution in a Plasma Opening Switch

    SBC: HY-Tech Research Corp.            Topic: N/A

    A GOOD MODEL FOR PREDICTING THE CONDUCTION AND OPENING CHARACTERISTICS OF PLASMA OPENING SWITCHES IS REQUIRED IF SWITCH- ES CURRENTLY IN USE ARE TO BE SCALED UP TO THE CURRENT AND VOLTAGE RATINGS REQUIRED BY THE FAMILY OF THREAT SIMULATOR. EMPIRICAL VERIFICATION OF THE NUMEROUS MODELS WHICH HAVE EVOLVED AROUND DIFFERENT CONDUCTION PROCESSES HAVE MET WITH LIMITED SUCCESS BECAUSE SWITCH CHARACTERIST ...

    SBIR Phase I 1993 Department of DefenseDefense Threat Reduction Agency
  5. SPECIAL MONITOR DETECTOR DEVELOPMENT FOR RESPIRATOR CONTAMINATION

    SBC: Shonka Research Associates            Topic: N/A

    N/A

    SBIR Phase I 1993 Nuclear Regulatory Commission
  6. NEW TECHNOLOGIES FOR IMPROVED SIMULATION OF NUCLEAR WEAPON EFFECTS

    SBC: Ares Corporation            Topic: N/A

    N/A

    SBIR Phase I 1990 Department of DefenseDefense Threat Reduction Agency
  7. HOLOGRAPHIC PATTERN RECOGNITION FOR ARMS CONTROL

    SBC: EMPIRICAL TECHNOLOGIES CORPORATION            Topic: N/A

    THE CONTRACTOR HAS PATENTED TECHNOLOGY FOR A UNIQUE PROCESS THAT DIRECTLY CONVERTS AN ACOUSTIC SIGNAL INTO A VISIBLE ONE IN REAL-TIME WITHOUT ELECTRONIC CIRCUITRY. THIS RELIES ON THE ACOUSTO-OPTICAL PROPERTIES OF A CONTINUOUS LAYER OF LIQUID CRYSTAL THIN FILM LAYER WHICH SERVES AS BOTH THE SENSOR AND THE DISPLAY. THE IMAGE CAN BE VIEWED DIRECTLY BY MEANS OF CCD CAMERA. HOLOGRAPHY PROVIDES FOR BOTH ...

    SBIR Phase I 1990 Department of DefenseDefense Threat Reduction Agency
  8. IMPROVED NEUTRON SPECTROMETER AND EXPOSURE METER

    SBC: Shonka Research Associates            Topic: N/A

    THE UNCERTAINTY IN MEASURING NEUTRON DOSE EQUIVALENT RATES RESULTS IN UNCERTAINTY IN ASSIGNMENT OF THE PROPER DOSE TO OCCUPATIONAL RECORDS AND CAN RESULT IN IMPROPER IMPLEMENTATION OF CONTROLS TO LIMIT THE EXPOSURE. A NOVEL PORTABLE NEUTRON SPECTROMETER IS PROPOSED WHICH WILL REDUCE THE UNCERTAINTY OF SUCH MEASUREMENTS TO LESS THAN 20%. MANYCOMPONENTS OF THIS DEVICE ARE COMMERCIALLY AVAILABLE. SYS ...

    SBIR Phase I 1990 Nuclear Regulatory Commission
US Flag An Official Website of the United States Government