  1. Objective Measurement Tool for Detection and Monitoring of Noise-Induced Hearing Loss

    SBC: Mimosa Acoustics Inc.            Topic: DHP15015

    We propose to take our binaural OtoStat-HCP hearing-test system, which was designed for advanced hearing-conservation programs (HCPs), and ruggedize it for use in theater. OtoStat-HCP includes pure-tone audiometry, otoacoustic emission (OAE), and wideband immittance tests. Commercial-off-the-shelf OAE systems are unsuitable for HCPs, so we will: 1) implement next-generation OAE tests to enable qua ...

    SBIR Phase II 2016 Department of DefenseDefense Health Agency
  2. Systems Biology Based Tools for Modeling Platelet Storage Lesion for Optimal Blood Transfusions

    SBC: CFD RESEARCH CORPORATION            Topic: DHP15011

    Vascular trauma is the leading cause of death in military environments and hemorrhage is the major preventable cause of mortality among trauma patients. Recent experience from Iraq and Afghanistan has demonstrated improved 24-h and 30-day survival in combat casualties requiring early massive transfusion. Unlike plasma and erythrocytes, which can be cold stored for longer time periods, platelets ca ...

    SBIR Phase II 2016 Department of DefenseDefense Health Agency
  3. Microfluidic Real-Time Monitoring Array with Graphene Enhanced Impedance Sensing for Coagulation Biomarker Profiling

    SBC: LYNNTECH INC.            Topic: DHP15012

    About 40% of trauma-related deaths are associated with rapid onset of coagulopathy. The vast majority of trauma patients are coagulopathic at the time of death. In Phase I, Lynntech demonstrated strong proof-of-concept for developing a novel, easy-to-use and cost effective device for quantitative real-time detection of a biomarker of coagulopathy, using human unprocessed whole blood as the input s ...

    SBIR Phase II 2016 Department of DefenseDefense Health Agency
  4. Data Integration and Predictive Analysis System (IPAS)

    SBC: KNOWLEDGE BASED SYSTEMS INC            Topic: DHP15008

    The goal of IPAS is to design and develop Data Integration and Predictive Analysis System (IPAS) that enables prediction, analysis, and response management of incidents of human infectious diseases.IPAS collects and integrates comprehensive datasets of previous disease incidents and potential influencing factors such as environmental, vector prevalence, demographic, health conditions, other diseas ...

    SBIR Phase II 2016 Department of DefenseDefense Health Agency
  5. TARGETED THERAPEUTIC ANTIBODY MOLECULES AGAINST VIRAL ENCEPHALITIS

    SBC: BIOO SCIENTIFIC CORPORATION            Topic: CBD161004

    VEEV/EEV/WWEEV are highly pathogenic alphaviruses that cause encephalitis in humans and equids. These infections are endemic in wide regions of the developing world. Translational research regarding these pathogens is focused on developing new strategies to detect, treat and ideally protect humans and animals from these infections. In this Phase I SBIR project, we will establish methodologies for ...

    SBIR Phase I 2016 Department of DefenseOffice for Chemical and Biological Defense
  6. Protective Mask Sizing App

    SBC: CFD RESEARCH CORPORATION            Topic: CBD161005

    Typical procedures for respirator masks sizing and protective fit test are time-consuming and user intensive, requiring taking anthropometric measurements of the wearer, sampling the wearers breathing zone and the use of specialized tools and equipment. The proposed software app aims to quickly, accurately and automatically perform respirator mask sizing and predict protective fit using only 2D im ...

    SBIR Phase I 2016 Department of DefenseOffice for Chemical and Biological Defense
  7. High Fidelity Computational Models for Aggregated Tissue Interaction in Surgical Simulations

    SBC: CFD RESEARCH CORPORATION            Topic: DHP16A001

    Surgical simulations aiming to support surgeon practices and medical education have attracted enormous research effort over the last two decades. However, the physical reality, especially on simulating aggregated tissue interaction, is still unsatisfactory. In this proposed work, an open source surgery simulation framework, SoFMIS, will be utilized and enhanced with tissue interaction models to a ...

    STTR Phase I 2016 Department of DefenseDefense Health Agency
  8. Personalized Warrior Health Avatar

    SBC: CFD RESEARCH CORPORATION            Topic: DHP16001

    The DOD is investing in mobile computing, information and warrior health systems to support network-centric military capabilities. Computerized health records, telemedicine, wearable monitoring, mHealth have the potential to reduce costs, promote health, ensure soldier fitness. The goal of this project is to design, develop, demonstrate, deploy a Warfighter Health Avatar (WHA), a simulation framew ...

    SBIR Phase I 2016 Department of DefenseDefense Health Agency
  9. Automated Vision Tester Technology Development for Aircrew Clinical Vision Screening

    SBC: VULINTUS, INC            Topic: DHP16004

    The objective of this Phase I proposal is to develop, design, and prototype a computer-based, Automated Vision Tester (AVT) for comprehensive vision screening of military aircrew. A fully realized AVT would combine a variety of clinical screening tests into a unified, automated tabletop unit capable of conducting screenings at both near (14 in./35 cm) and far (20 ft/6 m) distances. The ideal test ...

    SBIR Phase I 2016 Department of DefenseDefense Health Agency
  10. Portable Iron Screening System for Point-of-Care Iron Status Determination

    SBC: CFD RESEARCH CORPORATION            Topic: DHP16005

    Iron deficiency is one of the most common nutritional deficiencies in the United States. Left untreated, iron stores continue to deplete, resulting in iron deficiency anemia. Women undergoing basic military training are particularly susceptible to reduced iron stores. To date, there are no comprehensive point-of-care instruments for accurate determination of iron status. We propose to develop a no ...

    SBIR Phase I 2016 Department of DefenseDefense Health Agency