Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY19 is not expected to be complete until June, 2020.

  1. Innovative Respiratory Protection for Low Threat Environments

    SBC: D. Wheatley Enterprises, Inc.            Topic: CBD181002

    Respiratory equipment has always required the use of a face seal or neck dam to provide good levels of protection. Although proven to beeffective, this approach is constraining when conceiving future integrated systems and can heavily burden the wearer. The development of anew device for lower threat environments, now provides the opportunity to finally remove the rubber off the face. This program ...

    SBIR Phase I 2018 Department of DefenseOffice for Chemical and Biological Defense
  2. Process Development and Manufacture of an Antibody-based Therapy Against Sudan EbolaVirus

    SBC: BIOFACTURA, INC.            Topic: CBD171005

    Recently we have observed a massive outbreak of Ebola virus. This family of virus causes a significant bioterrorism threat due to the high levelof mortality, rate of transmissibility and the lack of an approved vaccine or therapy directed against it. The goal of this proposal is to develop,optimize and scale-up a mammalian cell culture-based bioprocess for the rapid manufacture of an antibody-base ...

    SBIR Phase I 2018 Department of DefenseOffice for Chemical and Biological Defense
  3. High-affinity monoclonal antibodies that target Burkholderia Polysaccharide

    SBC: DxDiscovery Incorporated            Topic: CBD14105

    The purpose of this contract is to develop high affinity antibodies that are specific to Burkholderia surface expressed polysaccharides. Thesemonoclonal antibodies (mAbs) can then be used to develop diagnostics and therapeutics for melioidosis and glanders; two infectious diseasescaused by the Tier 1 biothreats Burkholderia pseudomallei and mallei, respectively. The SBIR funded work to date develo ...

    SBIR Phase II 2018 Department of DefenseOffice for Chemical and Biological Defense
  4. MicroLens Hyperspectral Imager for Standoff Chemical Detection

    SBC: NANOHMICS INC            Topic: CBD171002

    For standoff chemical identification applications, the longwave infrared has several key lines for spectral discrimination.Unfortunately, most hyperspectral systems are quite large, making them unwieldy.Nanohmics proposes to develop a chip-scale longwave infrared hyperspectral imaging technology.The weight and packaging volume will be dominated by the fore-optics instead of the spectroscopy soluti ...

    SBIR Phase I 2018 Department of DefenseOffice for Chemical and Biological Defense
  5. High Sensitivity, Low Complexity, Multiplexed Diagnostic Devices

    SBC: Paratus Diagnostics            Topic: CBD152005

    Our goal is to provide the Department of Defense with a reliable, point-of-need diagnostic device that is field-deployable, appropriatelysensitive, and can be easily adapted for detection of a variety of biological targets that are of interest to the defense community. Phase I of thisproject was for the initial demonstration and development of our low-cost personal diagnostic platform (referred to ...

    SBIR Phase II 2018 Department of DefenseOffice for Chemical and Biological Defense
  6. AOTF Based Spectro-Polarimetric Imaging System For Stand Off Chemical Detection

    SBC: BRIMROSE TECHNOLOGY CORPORATION            Topic: CBD13104

    We propose an Acousto-Optic Tunable Filter (AOTF) Spectropolarimetric Imaging System for Enhanced Standoff Chemical Detection at Long Wave Infrared (LWIR) wavelengths. This work entails development of suitable LWIR material, design of the LWIR AOTF, and design of the hyperspectral imaging sensor using a focal plane array. Currently, there is no technologically mature, commercially available mater ...

    SBIR Phase II 2014 Department of DefenseOffice for Chemical and Biological Defense
  7. Development of Low Cost Infrared Focal Plane Array for Passive Chemical Detection Using Colloidal Quantum Dots

    SBC: BRIMROSE TECHNOLOGY CORPORATION            Topic: CBD13105

    We propose to develop low cost Long Wavelength Infrared Focal Plane Arrays (LWIR FPAs) using colloidal quantum dots (CQDs) of mercury telluride (HgTe). In Phase I, QDs in the size range of 20-25nm (corresponding to cutoff wavelength of 8 to 12 microns) w...

    SBIR Phase II 2014 Department of DefenseOffice for Chemical and Biological Defense
  8. Regenerable Carbon Dioxide Removal Technology Based on Novel Macroporous Ion Exchange Resins for Closed-Circuit Breathing Apparatus

    SBC: Lynntech Inc.            Topic: CBD12106

    Currently, the United States Military encounters many scenarios where soldiers must enter hazardous areas, while maintaining isolation from contaminants such as chemical and biological agents as well as hazardous material exposure. This requires that the soldiers respiratory tract be isolated to prevent exposure to these contaminants. In order to accomplish this, the soldiers wear protective suits ...

    SBIR Phase II 2014 Department of DefenseOffice for Chemical and Biological Defense
  9. Regenerable, heat-Abating, humidity-Neutralizing, Carbon diOxide Removal System (RANCOR) Phase II

    SBC: Paragon Space Development Corporation            Topic: CBD12106

    In Phase I RANCOR successfully demonstrated an innovative enabling humidity control technology to provide very low humidity air to water sensitive, fully reusable CO2 adsorbents. The use of adsorbents enables complete reusability/rechargability and reduces the total heat load on the SCBA to the point where ice or other cooling systems will no longer be required. In Phase II Paragon will introduce ...

    SBIR Phase II 2014 Department of DefenseOffice for Chemical and Biological Defense
  10. Development of Zeteo Toxic Agent Detection System (zTADS)

    SBC: Zeteo Tech LLC            Topic: CBD14101

    The development of the Zeteo Toxic Agent Detection System (zTADS) is presented here. The system features a multiplexed disposable sample collection and processing system that feeds a handheld biological mass spectrometer.

    SBIR Phase I 2014 Department of DefenseOffice for Chemical and Biological Defense
US Flag An Official Website of the United States Government