You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. High-Performance, Low SWaP, Radiation Hardened and Vibrationally Robust Inertial Measurement Unit Employing Fast Light Technology For Missile Defense

    SBC: DIGITAL OPTICS TECHNOLOGIES INC            Topic: MDA14019

    There is a need for new types of IMUs, with better accuracy than the state of the art. Digital Optics Technologies (DOT) has been developing a Fast Light Optical Gyroscope (FLOG) that can improve the accuracy of rotation sensing by nearly six orders of magnitude. Alternatively, for a given accuracy need, the FLOG can be very small. DOT has also developed a Fast Light Optical Accelerometer (FLOAC ...

    SBIR Phase I 2015 Department of DefenseMissile Defense Agency
  2. Innovative Data Architecture Generation Across a Complex System of Systems (SoS)

    SBC: COGNITECH CORPORATION            Topic: MDA14010

    In the Phase I research, our business will develop a preliminary Data Architecture, data model, and other architectural artifacts for a Big Data solution to manage Ballistic Missile Defense System (BMDS) System of Systems and related simulation data. The prime contractor of Objective Simulation Framework (OSF) will provide BMDS subject matter expertise and knowledge of existing systems and proces ...

    SBIR Phase I 2015 Department of DefenseMissile Defense Agency
  3. High Performance Noise-Suppressing Long Wavelength Infrared Mercury Cadmium Telluride Focal Plane Array (FPA) Sensors

    SBC: EPIR, INC.            Topic: MDA14021

    We propose the development of long wavelength infrared (LWIR) sensors based on HgCdTe in a novel noise-suppressing high temperature barrier (HTB) architecture, which combines the benefits of unipolar nBn and non-equilibrium, Auger-suppressing high operating temperature (HOT) structures. The proposed design is beneficial for controlling carrier conduction to minimize the number of majority and min ...

    SBIR Phase I 2015 Department of DefenseMissile Defense Agency
  4. High Performance Long Wave Infrared (LWIR) Focal Plane Array (FPA) Sensor for Missile Defense

    SBC: QMAGIQ LLC            Topic: MDA14021

    We propose to bandgap-engineer the antimony-based Group III-V compound semiconductor material system to realize a dualband focal plane array (FPA) made up of stacked multi-barrier Type-II strained layer superlattice (SLS) photodiodes. Two longwave infrared (LWIR) spectral bands will be imaged in alternate frames by using a readout multiplexer that flips the voltage bias across the FPA from frame ...

    SBIR Phase I 2015 Department of DefenseMissile Defense Agency
  5. Increased Lifetime and Decreased Dark Current in Ga-Containing Longwave Infrared (LWIR) Type-II Superlattices (T2SL) through Defect Identification and Mitigation

    SBC: SIVANANTHAN LABORATORIES, INC.            Topic: MDA14021

    Absorber layers based on Type-II superlattices (T2SLs) composed of III-V compound semiconductors (e.g. GaSb and InAs) are a promising sensor technology for infrared imaging; however, dark currents and short carrier lifetimes in the Ga-containing T2SL are significant problems. It is presently suspected that the short carrier lifetimes and some dark current arise due to a native point defect, possi ...

    SBIR Phase I 2015 Department of DefenseMissile Defense Agency
  6. Ruggedized Ceramic Circuit Card Assemblies

    SBC: MICRO-PRECISION TECHNOLOGIES, INC.            Topic: MDA13005

    Micro-Precision Technologies (MPT) will build, test, and deliver to military high-performance ceramic circuit card assemblies for the Throttling Divert and Attitude Control System (TDACS). Based on our commercially proven technology for ceramic-based hybrid microcircuit and multi-chip module manufacturing, we will meet the MDA requirements for increased solder toughness, reduced footprint and wei ...

    SBIR Phase II 2015 Department of DefenseMissile Defense Agency
  7. Integrated Systems Materials and Design ImprovementComposite Baffled Telescope and Mirror Substrate Manufacturing

    SBC: MENTIS SCIENCES INC            Topic: MDA13006

    The proposed Phase II R&D includes continue development of the honeycomb fabrication method developed in Phase I to assure accuracy and repeatability of the process. MENTIS then proposes to fabricate prototype honeycomb sunshades for telescopes, including those with the secondary mirrors embedded in the honeycomb matrix. Using the composite baffled sunshade developed by MENTIS, BAE will perform ...

    SBIR Phase II 2015 Department of DefenseMissile Defense Agency
  8. Tailored Ultrahigh Temperature Refractory Material Designs for Propulsion Applications

    SBC: EXOTHERMICS, INC.            Topic: MDA13025

    This Phase II SBIR proposal addresses the requirement to significantly improve the affordability and mission performance of SDACS propulsion components by embarking on a program to develop and optimize hafnium-based or hafnium hafnium nitride claddings for advanced structural insulator substrate materials of current interest to MDA programs.Phase II partner Materials Research & Design (MR&D), Wayn ...

    SBIR Phase II 2015 Department of DefenseMissile Defense Agency
  9. Field Deployable Otoacoustic Emissions Probe for Objective Tracking of Noise-Induced Hearing Loss

    SBC: CREARE LLC            Topic: DHP15015

    Progressive noise-induced hearing loss may jeopardize a service members ability to be deployed or continue in communication-critical job duties. It is the fourth leading cause of medical referral for service members returning from deployments. Distortion product otoacoustic emissions (DPOAEs) are a sensitive objective screening tool. However, commercially available DPOAE measurement systems are ...

    SBIR Phase I 2015 Department of DefenseDefense Health Agency
  10. Objective Measurement Tool for Detection and Monitoring of Noise-Induced Hearing Loss

    SBC: Mimosa Acoustics Inc.            Topic: DHP15015

    We propose to take our hearing-test device, which was designed to support research in advancing hearing-conservation programs, and ruggedize it for use in theater. Five key challenges that make the commercial-off-the-shelf OAE systems unsuitable for HCPs, will be overcome. We will: 1) implement next-generation otoacoustic emission tests to enable OAE measurements in noise-damaged ears, 2) add smar ...

    SBIR Phase I 2015 Department of DefenseDefense Health Agency
US Flag An Official Website of the United States Government