  1. SOLID-STATE CLINICAL GAS ANALYZER

    SBC: Albion Instruments            Topic: N/A

    A SMALLER, LIGHTER, MORE EFFICIENT, AND MORE RELIABLE CLINICAL GAS ANALYZER FOR RESPIRATORY AND ANESTHETIC GAS MONITORING IS NEEDED. EXISTING LASER RAMAN-BASED INSTRUMENTATION USES A LARGE, HEAVY, AND EXTREMELY INEFFICIENT (0.1 PERCENT) ARGON ION LASER WITH AN INTRACAVITY GAS CELL. THE LONG-TERM OBJECTIVE OF THIS STUDYIS TO IMPLEMENT A SOLID-STATE ALTERNATIVE TO THE EXISTING ION LASER. SUCH A LASE ...

    SBIR Phase I 1989 Department of Health and Human Services
  2. CLINICAL GAS ANALYZER

    SBC: Albion Instruments            Topic: N/A

    N/A

    SBIR Phase I 1989 Department of Health and Human Services
  3. WIRELESS INFRARED NICTATING COMMUNICATION SYSTEM NOVEL NEURAL NETWORK DEVICE

    SBC: Energy Optics, Inc.            Topic: N/A

    QUADRIPLEGICS HAVE SPECIAL COMMUNICATION NEEDS. THE OBJECTIVE OF THE WIRELESS INFRARED NICTATING COMMUNICATION SYSTEM (WINCS) PROJECT IS TO DEMONSTRATE THE FEASIBILITY OF A SPEAKER-TYPE TELEPHONE THAT COULD BE OPERATED DIRECTLY BY EYEBLINKS. A MICROPHONE ATTACHED TO THE SPEAKERPHONE WILL ALLOW THE USER TO CONTROL SUCH FUNCTIONS AS ANSWERING, HANGING UP, AND DIALING. A MEMORY DEVICE WILL BE INCORPO ...

    SBIR Phase I 1989 Department of Health and Human Services
  4. FLOW/STERIC FFF--A NEW METHOD FOR CELL SEPARATIONS

    SBC: Fffractionation, Llc.            Topic: N/A

    FLOW/STERIC FIELD-FLOW FRACTIONATION (FLOW/STFFF) IS A RECENTLY DEVELOPED METHOD WITH EXTRAORDINARY SPEED AND RESOLVING POWER DESIGNED TO SEPARATE PARTICULATE MATERIALS FALLING ROUGHLY IN THE 1 TO 100 MUM PARTICLE DIAMETER RANGE. THE OBJECT OF THIS PROJECT IS TO EXAMINE THE POTENTIAL OF CONVERTING THIS RESEARCH FINDING INTO A FAST AND RELIABLE TOOL FOR THE FRACTIONATION AND CHARACTERIZATIONOF CELL ...

    SBIR Phase I 1989 Department of Health and Human Services
  5. TISSUE PERFUSION MONITOR FOR FREE-TISSUE TRANSFER

    SBC: MEDICAL PHYSICS, INC.            Topic: N/A

    FREE TISSUE TRANSFER HAS REVOLUTIONIZED MANY AREAS OF RECONSTRUCTIVE SURGERY. AS FREE TISSUE TRANSFER IS NOW BEING DONE ROUTINELY AT INSTITUTIONS WHERE INEXPERIENCED STAFF ARE UNABLE TO ADEQUATELY MONITOR VIABILITY, THE NEED FOR A RELIABLE METHOD TO MONITOR THE PATENCY OF MICROVASCULAR ANASTOMOSES HAS BECOME INCREASINGLY EVIDENT. ACCURATE MONITORING OF BLOOD FLOW DURING AND AFTER SURGERY IS ESSENT ...

    SBIR Phase I 1989 Department of Health and Human Services
  6. INVERSION OF LAPLACE TRANSFORMS ON MICROCOMPUTERS

    SBC: Micromath Inc.            Topic: N/A

    THE APPLICATION OF PHYSICAL-CHEMICAL PRINCIPLES TO BIOLOGICAL SYSTEMS FREQUENTLY LEADS TO SITUATIONS IN WHICH THE QUANTITATIVE TREATMENT OF CONCEPTUALLY SIMPLE MODELS IS CONFOUNDED BY THE COMPLEXITY OF THE SYSTEM. SUCH IS THE CASE, FOR EXAMPLE, IN THE STUDY OF THE PERMEATION (AND POSSIBLE CONCURRENT METABOLISM) OF DRUGS THROUGH COMPLEX BIOLOGICAL MEMBRANES, THE PHYSIOLOGICAL MODELING OF THE DISTRI ...

    SBIR Phase II 1989 Department of Health and Human Services
  7. DYNAMIC ELECTRON ARC COLLIMATOR FOR RADIATION THERAPY

    SBC: Parvus Corpon            Topic: N/A

    RECENT INNOVATIONS IN MOTION-CONTROL TECHNOLOGY HAVE THE POTENTIAL TO PROVIDE THE VIABLE DESIGN AND DEVELOPMENT OF A PORTABLE, LIGHTWEIGHT, COMPUTER-CONTROLLED MULTIVANE COLLIMATOR THAT CAN BE USED SIMPLY AND EASILY IN TYPICAL RADIATION THERAPY FACILITIES, AS A THERAPY MACHINE ACCESSORY, TO PROVIDE IMPROVED DOSE UNIFORMITY IN ELECTRON ARC THERAPY. A PROTOTYPE MULTIVANE COLLIMATOR HAS BEEN COMPLETE ...

    SBIR Phase I 1989 Department of Health and Human Services
  8. RADIOLABELED ANTIBODY DELIVERY SYSTEM QUALITY CONTROL

    SBC: Rhomed, Inc.            Topic: N/A

    A QUALITY CONTROL (QC) TEST KIT WILL BE DEVELOPED AND AND VALIDATED FOR USE IN MEASURING THE PERCENTAGE OF IMMUNOREACTIVE RADIOACTIVITY OF RADIOLABELED ANTIBODY OR ANTIBODY FRAGMENTS INTENDED FOR PATIENT USE. THIS QC PRODUCT IS BEING DESIGNED FOR A MULTICENTERED CLINICAL TRIALOF COMPOUNDED, RADIOLABELED ANTIBODIES. PANELS OF CURRENTLYAVAILABLE MONOCLONAL ANTIBODIES (MABS) THAT HAVE POTENTIAL FOR T ...

    SBIR Phase II 1989 Department of Health and Human Services
  9. IMPROVED TECHNETIUM-99M LABELING FOR CANCER IMAGING

    SBC: Rhomed, Inc.            Topic: N/A

    N/A

    SBIR Phase I 1989 Department of Health and Human Services
  10. DEVELOPMENT OF AN ANESTHESIA WORKSTATION

    SBC: Rocky Mountain Research, Inc.            Topic: N/A

    N/A

    SBIR Phase I 1989 Department of Health and Human Services

Agency Micro-sites

SBA logo
Department of Agriculture logo
Department of Commerce logo
Department of Defense logo
Department of Education logo
Department of Energy logo
Department of Health and Human Services logo
Department of Homeland Security logo
Department of Transportation logo
Environmental Protection Agency logo
National Aeronautics and Space Administration logo
National Science Foundation logo
US Flag An Official Website of the United States Government