THEORETICAL AND EXPERIMENTAL CHARACTERIZATION OF FIBER-MATRIX INTERFACE IN SIC REINFORCED GLASS CERAMICS
SBC: ADTECH SYSTEMS RESEARCH INC Topic: N/AALTHOUGH THE USE OF CERAMIC COMPOSITES IN AEROSPACE SYSTEMS IS MONOTONICALLY INCREASING, THERE ARE NOT MANY ANALYTICAL AND EXPERIMENTAL STUDIES REVEALING THE UNIQUE CHARACTERISTICS THESE MATERIALS CAN PROVIDE. IT IS BELIEVED THAT THESE MATERIALS HAVE GREAT PROMISE FOR HIGH TEMPERATURE STRUCTURAL APPLICATIONS INCLUDING HOT TURBINE ENGINE COMPONENTS. WHILE FEW FIBER REINFORCED CERAMIC SYSTEMS ARE CO ...
SBIR Phase I 1989 Department of DefenseAir Force -
REMOVAL OF SULFUR OXIDES AND NITROGEN OXIDES FROM FLUE GAS BY CATALYTIC CONVERSION USING REDUCED ZIRCONIA
SBC: Advanced Ceramic Research Topic: N/AEMISSION OF SULFUR OXIDES (SOX) AND NITROGEN OXIDES (NOX) IN FLUE GASES IS A MAJOR CAUSE OF AIR POLLUTION AND ACID RAIN. CURRENT TECHNOLOGIES FOR SOX REMOVAL ARE EXPENSIVE AND CUMBERSOME. SULFUR DIOXIDE IS CONVERTED TO SULFURIC ACID, WHICH IS VERY CORROSIVE AND DIFFICULT TO STORE AND TRANSPORT. REMOVAL OF NOX IS ACCOMPLISHED BY CATALYTIC CONVERSION USING PLATINUM CATALYSTS. PLATINUM CATALYSTS ARE ...
SBIR Phase I 1989 Department of Energy -
SOLID-STATE CLINICAL GAS ANALYZER
SBC: Albion Instruments Topic: N/AA SMALLER, LIGHTER, MORE EFFICIENT, AND MORE RELIABLE CLINICAL GAS ANALYZER FOR RESPIRATORY AND ANESTHETIC GAS MONITORING IS NEEDED. EXISTING LASER RAMAN-BASED INSTRUMENTATION USES A LARGE, HEAVY, AND EXTREMELY INEFFICIENT (0.1 PERCENT) ARGON ION LASER WITH AN INTRACAVITY GAS CELL. THE LONG-TERM OBJECTIVE OF THIS STUDYIS TO IMPLEMENT A SOLID-STATE ALTERNATIVE TO THE EXISTING ION LASER. SUCH A LASE ...
SBIR Phase I 1989 Department of Health and Human Services -
IMPROVED POLLUTION CONTROL USING RAMAN SCATTERING GAS ANALYSIS
SBC: Albion Instruments Topic: N/AREAL TIME ON-LINE ANALYSIS OF STACK GASSES IS NECESSARY TO MONITOR EFFLUENTS AND TO PERMIT FEEDBACK CONTROL OF COMBUSTION PROCESS AND DOWN STREAM SCRUBBER SYSTEMS. MULTIMEDIA POLLUTION ANALYSIS REQUIRES MULTIPLE SENSOR TECHNOLOGY WITH PRESENT COMMERCIALLY AVAILABLE INSTRUMENTATION. CURRENTLY, COMPLEX ANALYTICAL SYSTEMS MUSTBE ASSEMBLED THAT ARE EXPENSIVE, PRONE TO DRIFT, AND DIFFICULT TO OPERATE A ...
SBIR Phase I 1989 Environmental Protection Agency -
CLINICAL GAS ANALYZER
SBC: Albion Instruments Topic: N/AN/A
SBIR Phase I 1989 Department of Health and Human Services -
COMPOSITE, HOLLOW FIBER MEMBRANE OXYGENATION DEVICE
SBC: ANATRACE, INC. Topic: N/ATHE ACCEPTANCE OF EXTRACORPOREAL OXYGENATION DEVICES BASED ON GAS TRANSFER THROUGH A MEMBRANE WILL DEPEND TO A LARGE EXTENT ON THE AVAILABILITY OF SIMPLER, EASIER TO USE, SAFER,AND LOWERCOST DEVICES. OXYGENATORS USING MICROPOROUS HOLLOWFIBERS HAVE COME INTO WIDER USE THE LAST FIVE YEARS. THEY PRESENT MORE MEMBRANE SURFACE TO BLOOD AND GAS PHASES FOR EQUIVALENT VOLUME AND DO NOT REQUIRE A SUPPLEMEN ...
SBIR Phase II 1989 Department of Health and Human Services -
GLYCATED HEMOGLOBIN BY AUTOMATED AFFINITY CHROMATOGRAPHY
SBC: ANATRACE, INC. Topic: N/ACLASSICAL ASSAYS FOR DETERMINING BLOOD AND URINE GLUCOSE HAVE LIMITED VALUE FOR THE MONITORING OF AN INDIVIDUAL'S BLOOD GLUCOSE LEVEL OVER TIME. MEASUREMENT OF GLYCATED HEMOGLOBIN (GHB) IS ALREADY GAINING ACCEPTANCE FOR MANAGEMENT OF PERSONS WITH DIABETES MELLITUS. GHB LEVELS ARE NOT ONLY USEFUL FOR DIAGNOSIS BUT ALSO FOR THE ESTABLISHMENT OF CARE GOALS AND FOR CARE REINFORCEMENT. IN THE FUTURE, M ...
SBIR Phase II 1989 Department of Health and Human Services -
3-D SURFACE TEXTURED PLATINUM ELECTRODE/GLUCOSE SENSOR
SBC: Applied Medical Technology Inc Topic: N/ATHIS PROGRAM IS RELATED TO THE DEVELOPMENT OF A PLATINUM-POLYSTYRENE ELECTRODE WITH TEXTURED SURFACE FOR A SUBCUTANEOUS ELECTROCATALYTIC SENSOR. THE SUBCUTANEOUS SENSOR HAS LOWER RISKS COMPARED TO AN INTRAVENOUS SENSOR, SOIT IS CONSIDERED FOR LONG-TERM MONITORING PURPOSES. IT HAS BEEN DEMONSTRATED THAT TEXTURED SURFACES ARE FAVORABLE FOR IMPLANTATION TO THE SOFT TISSUE DUE TO BETTER VASCULARIZATIO ...
SBIR Phase I 1989 Department of Health and Human Services -
PROCESSED VAPOR GROWN GRAPHITE FIBERS FOR ELECTROMAGNETIC RAILGUNS
SBC: Applied Sciences Inc. Topic: N/AREQUIREMENTS FOR RAILGUN ARMATURES DICTATE MATERIALS PROPERTIES VALUESWHICH ARE DIFFICULT TO OBTAIN FROM CONVENTIONAL MATERIALS. THE NEED EXISTS FOR A MATERIAL WHICH HAS LOW DENSITY, HIGH MELTING POINT, HIGH THERMAL CONDUCTIVITY, LOW COEFFICIENT OF THERMAL EXPANSION, HIGH ELECTRICAL CONDUCTIVITY, HIGH VALUES FOR STRENGTH, AND GOOD CHARACTERISTICS OF LUBRICITY. GRAPHITE FIBER GROWN FROM PYROLYSIS O ...
SBIR Phase II 1989 Department of DefenseMissile Defense Agency -
HIGH THERMAL CONDUCTIVITY COMPOSITES FOR THERMAL ENERGY MANAGEMENT
SBC: Applied Sciences Inc. Topic: N/ATHE ECONOMICS OF LAUNCH COST, COUPLED WITH POWER REQUIREMENTS FOR SPACE BASED WEAPONS SYSTEMS, MANDATE OPTIMIZATION OF THE RATIO OF POWER TO MASS IN SPACE POWER SYSTEMS. A LOW DENSITY, HIGH TEMPERATURE, RADIATION-COMPATIBLE MATERIAL WITH HIGH THERMAL CONDUCTIVITY USED FOR CONSTRUCTION OF THERMAL MANAGEMENT DEVICES WOULD OFFER A SUBSTANTIAL ENHANCEMENT TO THE POWER/MASS RATIO, AND TO THE COST OF DE ...
SBIR Phase I 1989 Department of DefenseNavy