You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. Fulcrum Biometrics' Plan for Research and Development of WS-BD Conformant Handheld Fingerprint Sensor

    SBC: Fulcrum Biometrics, LLC            Topic: N/A

    Trusted biometric validation of individual identities has never been more important. Several contributing factors are the increase in global terrorism, identity theft and the increase in legislation which are driving the accelerated adoption of biometric technology. Unfortunately, the biometrics industry has not actively responded to the changing market conditions being driven by the explosion in ...

    SBIR Phase I 2012 Department of CommerceNational Institute of Standards and Technology
  2. Microfabricated Broadband Connectors for Frequencies Above 100 GHz

    SBC: Nuvotronics, LLC            Topic: N/A

    The region of the electromagnetic spectrum from 100 GHz to 400 GHz is currently underutilized but an area of exciting promise. Although atmospheric attenuation is higher in this region, the high frequency enables higher bandwidth operation. Transmit and receive components are also small resulting in the potential for lightweight miniature systems. Sub-millimeter waves also have the unique ability ...

    SBIR Phase I 2012 Department of CommerceNational Institute of Standards and Technology
  3. Non-contact Inline Material Sensor for Measurement of Electrical Properties of Nanofiber Films

    SBC: PANERATECH, INC.            Topic: N/A

    PaneraTech is proposing a non-contact dual sensor for broadband and real-time characterization of thin nanofiber films during the manufacturing. Our solution offers several unique aspects that are ideal for this application. For instance, it uses a dual CPW sensor for low frequencies and free space transmission system for higher frequency band. Our proposed sensor system is also equipped with high ...

    SBIR Phase I 2012 Department of CommerceNational Institute of Standards and Technology
  4. High-Throughput Manufacturing Methods for Engineered MRI Contrast Agents

    SBC: ADVANCED RESEARCH CORPORATION            Topic: 9010368R

    This project focuses on developing a magnetic resonance imaging (MRI) contrast agent that may increase the detection of tagged cells by a factor of 10-100. The ability to noninvasively track specifically labeled (tagged) cells, enables a researcher or medical treatment professional to dynamically monitor the delivery and targeted application of medicinal and bio-reactive agents.

    SBIR Phase I 2015 Department of CommerceNational Institute of Standards and Technology
  5. Large-Area, High-Uniformity Photodiodes for Infrared Trap Detectors

    SBC: AMETHYST RESEARCH INC            Topic: 9020168R

    methyst Research Inc. will design, fabricate and test a high uniformity, large area, low noise infrared trap-detector detector for the 1- 4.5 μm wavelength range. This state of the art detector will have a large area (e.g., 1-1.8 cm diameter active area) with a spatial variability of internal quantum efficiency of less than 0.1 % between 1 μm and 4.5 μm. In addition, the internal quantum effici ...

    SBIR Phase I 2015 Department of CommerceNational Institute of Standards and Technology
  6. Combined Extinction/Fluorescence Absorption Diagnostics for Sprays

    SBC: En'urga Inc.            Topic: 9030163R

    This Phase II project will continue the prototype development of a pharmaceutical spray quality audit system. The spray quality audit system will estimate the planar mass distribution, mass flux, and drop size of pharmaceutical sprays that are used in functional coating applications and inhalers. A prototype tomography system will be designed and fabricated and evaluated using various fluorophore.

    SBIR Phase II 2015 Department of CommerceNational Institute of Standards and Technology
  7. Precision 10 kV Programmable Voltage Source

    SBC: Low Thermal Electronics, Inc.            Topic: NA

    Low Thermal Electronics, Inc. proposes to design a stand-alone, programmable voltage source capable of supplying precision voltages in the range of zero to 1,000 volts direct current (DC), with options for scaling up to 10,000 volts, and with a total expanded uncertainty (k=2) of less than 10uV/V for the 10,000 volt version. This instrument will improve state-of-the-art measurements in high resist ...

    SBIR Phase I 2017 Department of CommerceNational Institute of Standards and Technology
  8. ISABEL- Integrated Secure Automated Bug Extraction List

    SBC: SMART INFORMATION FLOW TECHNOLOGIES LLC            Topic: NA

    The ISABEL program will create symbolic execution signatures to classify bugs in the NIST Bugs Framework. Using the symbolic execution signature ISABEL will find a program input to trigger the bug using fuzz testing. ISABEL will integrate its bug categorization and bug triggering capability with a software development environment using a flexible framework that will allow both open source and comm ...

    SBIR Phase I 2017 Department of CommerceNational Institute of Standards and Technology
  9. High Density Semi-Auto Closed Cycle Cryoprober II

    SBC: MICROXACT INC.            Topic: NA

    High density wafer scale cryogenic probing solution for testing at 4.5K temperatures or below is needed for testing and characterization of devices and circuits employing superconducting electronic components (such as used for quantum processing, high speed classical processing, magnetic field sensors, etc.) as well as for testing of various particle and light detectors for astronomy, aerospace, d ...

    SBIR Phase II 2017 Department of CommerceNational Institute of Standards and Technology
  10. Fiber Pigtailed On-Chip Mid-infrared Difference Frequency Generation in Silicon

    SBC: OMEGA OPTICS, INC.            Topic: NA

    We propose a fiber-pigtailed strained silicon platform for tunable difference frequency generation (DFG) in mid-infrared (MIR) with tunable continuous wave near-infrared (NIR) sources. Stress exerted by silicon nitride induces second-order nonlinear susceptibility c(2) on underlying centro-symmetric silicon. NIR light is coupled into silicon and MIR light is coupled out of silicon using sub-wavele ...

    SBIR Phase II 2017 Department of CommerceNational Institute of Standards and Technology
US Flag An Official Website of the United States Government