List

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for the given year is not complete until April of the following year. Annual Reports data is a snapshot of agency reported information for that year and hence might look different from the live data in the Awards Information charts.

  1. Compact Raman Fiber Optic Probe with Inline Spectral Filtering

    SBC: Nikira Labs Inc.            Topic: None

    In this Small Business Innovative Research (SBIR) effort, Nikira Labs Inc. proposes to develop a compact Raman fiber optic probe with inline spectral filtering that improves fiber-coupled Raman measurements by filtering out Raman scattering from the excitation fiber and elastically scattered laser light from the collection fibers. The technology will enable compact fiber probes for Raman studies i ...

    SBIR Phase II 2019 Department of CommerceNational Institute of Standards and Technology
  2. Developing Silicon Nanowire Sensors to Measuring Host-Cell Proteins at a Biomanufacturing Line

    SBC: Advanced Silicon Group            Topic: None

    Our biosensor is made of silicon nanowire arrays functionalized with antibodies to measure the concentration of specific proteins. In this grant we will take a sensor that has been demonstrated for use in measuring a set of generic host cell proteins and we will apply the sensor to measure a set of proteins for a specific cell line. In doing so, we will demonstrate the utility of our sensor to be ...

    SBIR Phase II 2019 Department of CommerceNational Institute of Standards and Technology
  3. IF Conversion System for High-Bandwidth Multiplexed Sensors Arrays

    SBC: Alphacore, Inc.            Topic: None

    Alphacore will develop an Intermediate Frequency (IF) Conversion System for High-Bandwidth Multiplexed Sensors Arrays for Phase II of NIST's 2018 soliciation for Exploratory Measurement Science Topic 9.04.02.68.The proposing team has already successfully developed and evaluated a prototype board in Phase I.The goal in Phase II is therefore to achieve three primary objectives:1) Optimize the design ...

    SBIR Phase II 2019 Department of CommerceNational Institute of Standards and Technology
  4. Multimode Chiroptical Spectrometer for Nanoparticle Characterization

    SBC: Applied Nanofluorescence LLC            Topic: None

    This project will develop a new scientific instrument optimized for the advanced characterization of near-infrared fluorescent nanoparticles that can exist as left- or right-handed structures (enantiomers). Single-walled carbon nanotubes (SWCNTs) are the leading current example of such nanomaterials. Applied NanoFluorescence, LLC (ANF) proposes a novel multi-mode chiroptical spectrometer that can ...

    SBIR Phase II 2019 Department of CommerceNational Institute of Standards and Technology
  5. TheSieve

    SBC: Cyber Point International, LLC            Topic: None

    CyberPoint International presents the design of a cross platform product for the autonomous execution of live forensic investigations of Personal Computers, Laptops and Servers leveraging the NIST NSRL corpus and a combination of at least 3 forms of machine learning/artificial intelligent algorithms for the processing of preliminary digital evidence titled TheSieve. We build upon work from our pha ...

    SBIR Phase II 2019 Department of CommerceNational Institute of Standards and Technology
  6. Dual Plane 3D Compton Scattering Imager with Pixelated CZT Detectors for 1-10MeV Gamma Ray

    SBC: H3D            Topic: None

    Phase I has proven that the current setup achieves better than 8mm spatial resolution for 2.2MeV prompt gammas. However, 1mm spatial resolution presents a significant challenge for the current setup due in part to limited timing resolution and count rate. A new analog ASIC will be developed to replace the current analog ASIC that will have better timing resolution and deliver higher count rates. I ...

    SBIR Phase II 2019 Department of CommerceNational Institute of Standards and Technology
  7. CSAT: A User-friendly Efficient NIST-spec Information System Development Guideline Tool

    SBC: INFOBEYOND TECHNOLOGY, LLC            Topic: None

    NIST developed risk management framework and guidelines that assist agencies to implement integrated, organization‐wide programs to manage information security risk, and further developed Cloud Security Architecture Tool (CSAT) to facilitate in this matter. However, NIST’s CSAT needs further improvement and implementation of new functions such that it can be commercialized as an Enterprise‐g ...

    SBIR Phase II 2019 Department of CommerceNational Institute of Standards and Technology
  8. Advanced Instrumentation for Non-Nulling Stack Velocity Testing

    SBC: AIRFLOW SCIENCES CORPORATION            Topic: None

    Industrial facilities, manufacturing plants, and electric power plants that burn fossil fuels exhaust the combustion products to atmosphere through their smokestacks. Stack pollutant emissions are quantified using manual testing methods developed in the 1960s, which are prone to error if non-axial flow exists in a stack.Recently, NIST has been working on an improved technique of performing 3D flow ...

    SBIR Phase I 2019 Department of CommerceNational Institute of Standards and Technology
  9. Continuous Monitoring of Natural Gas Infrastructure for Increased Community Resilience using Voltammetric Sensors

    SBC: FULLMOON SENSORS, INC.            Topic: None

    Fullmoon has the first chip-level sensors capable of identifying and quantifying molecules in the air. At the core of our technology are printed voltammetric sensors, which are operated using cyclic voltammetry, an electrochemical technique that probes for the redox potential, a unique signature of molecules. We have demonstrated this sensing principle for the detection of carbon monoxide and meth ...

    SBIR Phase I 2019 Department of CommerceNational Institute of Standards and Technology
  10. Microcapillary Quartz Sensors for Screening Injectability of High Concentration Protein Formulations

    SBC: Qatch Technologies, LLC            Topic: None

    The objective of this SBIR Phase I proposal is to determine the feasibility of viscosity characterization of high concentration protein formulations (HCF) by QATCH’s microcapillary quartz technology. HCFs are non-Newtonian fluids with shear-thinning behavior and they are administered to patients by subcutaneous or muscular injections. The injectability of HCFs depends on the viscosity at high-sh ...

    SBIR Phase I 2019 Department of CommerceNational Institute of Standards and Technology

Agency Micro-sites

SBA logo
Department of Agriculture logo
Department of Commerce logo
Department of Defense logo
Department of Education logo
Department of Energy logo
Department of Health and Human Services logo
Department of Homeland Security logo
Department of Transportation logo
Environmental Protection Agency logo
National Aeronautics and Space Administration logo
National Science Foundation logo
US Flag An Official Website of the United States Government