You are here
Award Data
The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.
Download all SBIR.gov award data either with award abstracts (290MB)
or without award abstracts (65MB).
A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.
The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.
-
Diamond Fast Opening Switch for High Voltage, High Average Power X-Ray, Elec
SBC: ALAMEDA APPLIED SCIENCES CORPORATION Topic: N/AAlameda Applied Sciences Corporation (AASC) proposes to develop an all-solid-state, compact, portable, multi-gigawatt poer modulator for electron and ion beam diodes, high power microwave and x-ray sources. This modulator is based on Inductive Energy Store (IES) using an array of Diamond Opening Switches for power compression. Because power amplification using IES requires a much smaller volume ...
SBIR Phase I 1996 Department of DefenseDefense Threat Reduction Agency -
Compact, Rugged, Flexible Fiber Optic Interferometer for Sensitive Gas and P
SBC: ALAMEDA APPLIED SCIENCES CORPORATION Topic: N/AAlameda Applied Sciences Corporation (AASC) proposes to develop a new type of interferometer that is compact and portable and can be used to make in-situ measurements of gases and plasmas. This interferometer uses polarization maintaining optical fibers and diode lasers to duplicate the capabilities of existing Mach-Zender interferometers that use dicrete optical elements such as mirrors, lenses ...
SBIR Phase I 1996 Department of DefenseDefense Threat Reduction Agency -
Diamond Real Time, Integrating Dosimeters
SBC: ALAMEDA APPLIED SCIENCES CORPORATION Topic: N/AAlameda Applied Sciences Corporation (AASC) proposes to develop a new class of real time integrating diamond radiation dosimeters. In Phase I AASC will demonstrate the feasibility of using diamond radiation detectors for monitoring personnel radiation dose. The sensitivity of these detectors will be determined and a concept design for a pocket real time dosimeter will be completed. The Phase ...
SBIR Phase I 1997 Department of DefenseDefense Threat Reduction Agency -
DEVELOPMENT OF A DYNAMIC OPERATIONAL RISK MODEL TO SUPPORT RISK MANAGEMENT OF NUCLEAR POWER PLANTS
SBC: Accident Prevention Group Topic: N/ACURRENT ACTIVITY WITHIN THE NRC AND THE NUCLEAR INDUSTRY SEEKS TO EXPLOIT THE BENEFITS OF PRA IN RISK-BASED APPROACHES TO RELIEVE REGULATORY BURDEN ON THE ECONOMICALLY THREATENED NUCLEAR POWER PLANTS. THE ACCIDENT PREVENTION GROUP HAS BEEN DEVELOPING THE CONCEPT OF AN INTEGRATED RISK MANAGEMENT PROGRAM (IRMP) TOWARD SUCH GOALS. A KEY ELEMENT OF AN IRMP IS AN "OPERATIONAL RISK MODEL" OF THE NPP THA ...
SBIR Phase I 1994 Nuclear Regulatory Commission -
RESPONSE OF SUPERCONDUCTING MATERIALS AND ELECTRONICS TO TRANSIENT RADIATION
SBC: Amador Research Corp Topic: N/AAN EXPERIMENT IS PROPOSED TO DEMONSTRATE THAT TRANSIENT X-RAY RADIATION FROM THE PHYSICS INTERNATIONAL PULSERAD 1150 FLASH X-RAY MACHINE WILL CAUSE A REPRESENTATIVE HIGH TEMPERATURE SUPERCONDUCTING (HTS) DEVICE TO MALFUNCTION BY REVERTING TO NORMAL CONDUCTIVITY. INTEREST IN THIS PHENOMENON IS MOTIVATED BY THE ANTICIPATED INCORPORATION OF HTS THIN FILM TECHNOLOGY IN DEFENSE ELECTRONICS, ESPECIALLY ...
SBIR Phase I 1990 Department of DefenseDefense Threat Reduction Agency -
NEW TECHNOLOGIES FOR IMPROVED SIMULATION OF NUCLEAR WEAPON EFFECTS
SBC: Ares Corporation Topic: N/AN/A
SBIR Phase I 1990 Department of DefenseDefense Threat Reduction Agency -
Increasing Bremsstrahlung Output with a Clean Diode
SBC: BERKELEY RESEARCH ASSOC., INC. Topic: N/AThe DM1 module that is a building block of DSWA's DECADE simulator has excellent electrical performance, but the final radiation pulse is erratic and often unsatisfactory. The probable cause is a parasitic current in ions, or through a diode plasma. This proposal is to evaluate a diode configuration that should suppress ions and plasma, namely a cathode of carbon fibers covered with cesium iodid ...
SBIR Phase I 1997 Department of DefenseDefense Threat Reduction Agency -
Hard X-Ray Spectrometer for Use During Radiation Tests and High Gain/Bandwidth Integrated Photodetec
SBC: BERKELEY RESEARCH ASSOC., INC. Topic: N/AWe propose to develop a differential absorption spectrometer that is small enough to be compatible with a test package in a bremsstrahlung test of electronics. In contrast to previous spectrometers, which use individual filter-detector combinations, the present instrument consists of concentric hemispherical shells. This design minimizes the spectrometer's mass, allowing it to be placed in front ...
SBIR Phase I 1997 Department of DefenseDefense Threat Reduction Agency -
Silicon-on Diamond Technology for Radiation Hardened Electronics
SBC: Crystallume/edi Topic: N/AThe objective of this program is to develop a silicon-on-insulator technology (SOI) using CVD diamond films as insulators. Such structures should permit the fabrication of integrated circuits with performance capabilities superior to those fabricated using conventional SOI structures including silicon-on-Sapphire (SOS), SIMOX, Epitaxial Layer Overgrowth (ELO) and Bond Etchback SOI (BESOI). Diamond ...
SBIR Phase I 1994 Department of DefenseDefense Threat Reduction Agency -
HOLOGRAPHIC PATTERN RECOGNITION FOR ARMS CONTROL
SBC: EMPIRICAL TECHNOLOGIES CORPORATION Topic: N/ATHE CONTRACTOR HAS PATENTED TECHNOLOGY FOR A UNIQUE PROCESS THAT DIRECTLY CONVERTS AN ACOUSTIC SIGNAL INTO A VISIBLE ONE IN REAL-TIME WITHOUT ELECTRONIC CIRCUITRY. THIS RELIES ON THE ACOUSTO-OPTICAL PROPERTIES OF A CONTINUOUS LAYER OF LIQUID CRYSTAL THIN FILM LAYER WHICH SERVES AS BOTH THE SENSOR AND THE DISPLAY. THE IMAGE CAN BE VIEWED DIRECTLY BY MEANS OF CCD CAMERA. HOLOGRAPHY PROVIDES FOR BOTH ...
SBIR Phase I 1990 Department of DefenseDefense Threat Reduction Agency