You are here
Award Data
The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.
Download all SBIR.gov award data either with award abstracts (290MB)
or without award abstracts (65MB).
A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.
The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.
-
Analysis Tools for Detection and Diagnosis of Biological Threats
SBC: ALPHA-GAMMA TECHNOLOGIES, INC. Topic: CBD04113DNA microarray technology, in combination with statistical and predictive modeling tools, could be used to evaluate thousands of genes against distinct gene expression patterns induced by chemical/biological agents to provide early identification and speed therapeutic intervention. The overall objective of this Phase II effort is to leverage existing public domain resources and commercial tools t ...
SBIR Phase II 2005 Department of DefenseOffice for Chemical and Biological Defense -
Filovirus drug discovery using novel combinations of approved drugs
SBC: APATH, LLC Topic: CBD05119The goal of this proposal is find novel combinations of approved drugs for the treatment and/or prevention of infection with filoviruses. Ebola and Marburg viruses, the only filoviruses, cause an acute hemorrhagic fever syndrome which has a high mortality rate and poses a significant bio-terrorism threat. There are currently no therapeutic agents available to treat filovirus infections and the de ...
SBIR Phase I 2005 Department of DefenseOffice for Chemical and Biological Defense -
Construction of a Force Probe for Characterization of Microscale Features
SBC: INSITUTEC, INC. Topic: N/AThe pressing need exists within industry to accurately measure high aspect ratio microscale structures. For example, diesel injector nozzles are manufactured with microscale holes ranging from 50-200 micrometers in diameter and 3-5 mm depths. One fundamental challenge is to nondestrucvely measure these features in order to validate models, enhance manufacturing processes, and reduce fuel emissions ...
SBIR Phase I 2005 Department of CommerceNational Institute of Standards and Technology -
A Submersible Video Recorder for Marine Biological Surveys
SBC: MANAGEMENT SCIENCES INC Topic: 8113We propose research to develop and demonstrate a deeply submersible video plankton recording system (ViPR) to perform image recording of plankton. The ViPR will apply artificial intelligence to 2-D or 3-D imaging using pattern recognition for a statistically reliable survey of plankton using two cameras, one for larger zooplankton and the other for microplankton. The ViPR computer will be PC compl ...
SBIR Phase I 2005 Department of Commerce -
Handheld Photoacoustic Chemical Agent and Toxic Industrial Material Detector
SBC: MANNING APPLIED TECHNOLOGY Topic: CBD05112Manning Applied Technology proposes to develop a handheld infrared spectrometer, ideally suited to detection of airborne chemical agents at and below permissible exposure limits. This approach offers unmatched sensitivity and specificity for detection of all types of chemical vapors. The instrument is modular, rugged, compact and highly sensitive. Volume pricing will be less than $1000 each. ...
SBIR Phase I 2005 Department of DefenseOffice for Chemical and Biological Defense -
Hermetic Textile Closure Hardware System
SBC: SIGMA K CORP Topic: CBD04110Effective collective protection fabrics must have a reliable closure system. During our Phase I Work Plan, Sigma-K began developing a Hermetic Textile Closure Hardware (HATCH) system. The HATCH combines both a magnetic and geometric self locking mechanism that will provide a hermetic seal when closed. Our current Phase I successes include developing self closing samples that can provide a hermetic ...
SBIR Phase II 2005 Department of DefenseOffice for Chemical and Biological Defense -
Low-Cost Microcalorimeter Spectrometer for X-Ray Macroanalysis
SBC: STAR CRYOELECTRONICS, LLC Topic: N/AA low-cost superconducting transition edge sensor (TES) microcalorimeter spectrometer is described for high energy and high spatial resolution X-ray energy dispersive spectroscopy and microanalysis. The proposed microcalorimeter instrument offers an energy resolution that is comparable to and potentially even better than wavelength dispersive spectrometers, thereby enabling the resolution of inter ...
SBIR Phase II 2005 Department of CommerceNational Institute of Standards and Technology -
Analysis Tools for Detection and Diagnosis of Biological Threats
SBC: ALPHA-GAMMA TECHNOLOGIES, INC. Topic: CBD04113DNA microarray technology, in combination with statistical and predictive modeling tools, could be used to evaluate thousands of genes against distinct gene expression patterns induced by chemical/biological agents to provide early identification and speed therapeutic intervention. The overall objective of this proposal is to demonstrate the feasibility of building a data management system for DN ...
SBIR Phase I 2004 Department of DefenseOffice for Chemical and Biological Defense -
Sensitive Molecular Beacons (MB) Based DNA Microarray
SBC: BIOMACHINES, INC. Topic: CBD02101In the wake of the September 11th attacks and subsequent Anthrax scares, researchers worldwide are working to expand our ability to rapidly assess what poses a terrorism threat to the public. The rapid detection of specific pathogens is required for biod
SBIR Phase II 2004 Department of DefenseOffice for Chemical and Biological Defense -
Hermetic Textile Closure Hardware System
SBC: SIGMA K CORP Topic: CBD04110Sigma-K Corporation proposes to develop a Hermetic Textile Closure Hardware System to be used for Chemical Biological (CB) protective clothing and Collective Protection (COLPRO) portable shelter systems. Our Hermetic Textile Closure Hardware System design will allow the user to easily don and doff one's protective apparel. The system will remain intact during combat behavior. The closure interface ...
SBIR Phase I 2004 Department of DefenseOffice for Chemical and Biological Defense