You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. Development and Prototyping of a Digital Pulse Processor for Improved Coincidence Detection, Rejection, and Pulse Recovery, for High Count-Rate Silicon Drift Detectors

    SBC: 4pi Analysis, Inc.            Topic: N/A

    The recent emergence of the Silicon Drift detector (SDD), for use in energy dispersive x-ray spectrometry (EDS), has made possible x-ray event streams with count rates as high as 1-10 Mcps. A problem with existing digital signal processing, as applied to SDDs, is the significant presence of coincidence peaks above the x-ray background. These coincidence peaks occur with amplitudes comparable to lo ...

    SBIR Phase II 2009 Department of CommerceNational Institute of Standards and Technology
  2. Model 8686H, Precision Resistance-Ratio Bridge

    SBC: Circuit Equipment Corporation            Topic: N/A

    The result of this project will be a fully functional prototype of the Model 8686H Precision Resistance-Ratio AC Bridge. The unit is capable of measuring resistances from 0 to 400 ohms with better than 0.1 uohm resolution and an accuracy of better than +/-0.05ppm. The unit will have advanced features such as a built-in web-browser, USB interface and built-in complex functions. Examples of such com ...

    SBIR Phase II 2009 Department of CommerceNational Institute of Standards and Technology
  3. Ground-Based Water Vapor Profiling Lidar

    SBC: Bennett Aerospace, Inc.            Topic: 832

    The vertical water vapor profile into the atmosphere is measured around the world using balloon-borne radiosondes that take measurements twice a day when the balloons are launched. The objective of this proposal is to establish the feasibility of measuring the amount of water vapor vertically, in the atmosphere as a function of altitude using a Light Detection and Ranging (lidar) operating in the ...

    SBIR Phase I 2009 Department of Commerce
  4. Large Area Domain Engineered Thin Film Pyroelectric Detectors

    SBC: SRICO INC            Topic: N/A

    This Small Business Innovation Research Phase II project uses the ¿smart-cut¿ methods to produce high performance and advanced functionality lithium tantalate pyroelectric sensors. Phase I has been devoted to feasibility demonstration of the ¿smart-cut¿ process, preliminary design studies for the advanced pyroelectric detectors and prototype device fabrication and testing. The Phase I ...

    SBIR Phase II 2009 Department of CommerceNational Institute of Standards and Technology
  5. Analysis Tools for Detection and Diagnosis of Biological Threats

    SBC: ALPHA-GAMMA TECHNOLOGIES, INC.            Topic: CBD04113

    DNA microarray technology, in combination with statistical and predictive modeling tools, could be used to evaluate thousands of genes against distinct gene expression patterns induced by chemical/biological agents to provide early identification and speed therapeutic intervention. The overall objective of this Phase II effort is to leverage existing public domain resources and commercial tools t ...

    SBIR Phase II 2005 Department of DefenseOffice for Chemical and Biological Defense
  6. Construction of a Force Probe for Characterization of Microscale Features

    SBC: INSITUTEC, INC.            Topic: N/A

    The pressing need exists within industry to accurately measure high aspect ratio microscale structures. For example, diesel injector nozzles are manufactured with microscale holes ranging from 50-200 micrometers in diameter and 3-5 mm depths. One fundamental challenge is to nondestrucvely measure these features in order to validate models, enhance manufacturing processes, and reduce fuel emissions ...

    SBIR Phase I 2005 Department of CommerceNational Institute of Standards and Technology
  7. Integrated Control System for an Adiabatic Demagnetization Refrigerator

    SBC: Lake Shore Cryotronics, Inc.            Topic: N/A

    There are emerging markets that are driven by advances in x-ray micro-calorimeters. These detectors allow an energy resolution 10x better than existing commercial x-ray detectors. The primary application is the detection and analysis of nanoscale particle contaminates in IC production. The temperature stability of the micro-calorimeter is critical for real-time analysis and maintaining the x-ray l ...

    SBIR Phase I 2005 Department of CommerceNational Institute of Standards and Technology
  8. Handheld Photoacoustic Chemical Agent and Toxic Industrial Material Detector

    SBC: MANNING APPLIED TECHNOLOGY            Topic: CBD05112

    Manning Applied Technology proposes to develop a handheld infrared spectrometer, ideally suited to detection of airborne chemical agents at and below permissible exposure limits. This approach offers unmatched sensitivity and specificity for detection of all types of chemical vapors. The instrument is modular, rugged, compact and highly sensitive. Volume pricing will be less than $1000 each. ...

    SBIR Phase I 2005 Department of DefenseOffice for Chemical and Biological Defense
  9. Decontamination of Biological Warfare (BW) Agents, Toxic Industrial Chemicals (TICs) and Toxic Industrial Materials (TIMs)

    SBC: MATERIALS ENGINEERING AND TECHNICAL SUPPORT SERVICES CORP.            Topic: CBD05113

    The US Government has spent hundreds of millions of dollars developing decontamination capabilities to protect our military personnel and equipment from chemical warfare agents. With much of the traditional research and development efforts within focused on decontamination of chemical warfare (CW) agents, there has been a recent shift in the research base to include biological warfare (BW) agents ...

    SBIR Phase I 2005 Department of DefenseOffice for Chemical and Biological Defense
  10. Reducing the Weight and Volume of Peroxide-Based Decontaminant by using a Solid (Vice Liquid) Component for Hydrogen Peroxide

    SBC: MATERIALS ENGINEERING AND TECHNICAL SUPPORT SERVICES CORP.            Topic: CBD05114

    Several new generation chemical and biological (CB) decontaminants are based on hydrogen peroxide (H2O2) chemistry. These new decontaminants have many desirable characteristics, including reactivity toward a broad spectrum of CB agents and toxins, as well as being less corrosive and more environmentally friendly than conventional decontaminating materials. However, these systems are still liquid b ...

    SBIR Phase I 2005 Department of DefenseOffice for Chemical and Biological Defense
US Flag An Official Website of the United States Government