You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. Optical Instrumentation for MEMS Oscillatory Parallel-Plate Rheometer

    SBC: AGILTRON, INC.            Topic: 9060563R

    Leveraging Agiltron’s industrial leading developments for optical measurement of motion in MEMS devices, we propose to use electro-optical sensors for measuring the displacement and gap in the NIST micro-rheometer. No electrical connections are required to the moving parts. All electronics and optics are removed from the chip so that it is inexpensive and disposable. A fixed, simple micro-fluidi ...

    SBIR Phase I 2011 Department of CommerceNational Institute of Standards and Technology
  2. Production Methods and Software for NIST Calibration Phantoms

    SBC: SIGMA K CORP            Topic: 9050868TT

    Currently, there are over 10,000 MRI scanners used in the US alone. US citizens today are mobile and many times medical treatments may require MRI scans from several different facilities. Images from MRI scanners can also drift over time. There is a tremendous need for all medical imaging scanners to be on the same level. Sigma-K will develop the commercialization of the ISMRM/NIST MRI Calibration ...

    SBIR Phase I 2011 Department of CommerceNational Institute of Standards and Technology
  3. High Speed and High Sensitivity Quadrant Photodetector

    SBC: RADIATION MONITORING DEVICES, INC.            Topic: 912085R

    To further advance the characterization and utility of microcantilevers, next generation optical detectors with higher frequency response, improved displacement resolution and lower noise for weak signal detection are needed. Consequently, Radiation Monitoring Devices, Inc. (RMD) will develop a turnkey optical detector module for use in characterizing the displacement and resonant frequencies of m ...

    SBIR Phase II 2011 Department of CommerceNational Institute of Standards and Technology
  4. A Single Aperature Dual-Wavelength Dual Polarized Antenna for AWRAP

    SBC: REMOTE SENSING SOLUTIONS, INC.            Topic: 834D

    Severe weather impacts our daily lives, society and nation’s economy. From an average of $10B (2005 dollars) annual loss due to tropical cyclones since 1900 to $200B in the commercial shipping industry that is threatened by severe ocean storms to the hundreds of lives and assets being lost in the $20B recreational boating industry. In these cases and many more, accurate now-casting and forecasti ...

    SBIR Phase I 2011 Department of CommerceNational Oceanic and Atmospheric Administration
  5. Rapid, Quantitative Biological Indicator System with Bacillus thuringiensis Al Hakam Spores(1001-677)

    SBC: TRITON SYSTEMS, INC.            Topic: CBD11101

    Biological agents pose high threats, because they are invisible and odorless and a relatively small amount can infect a large population when released in a densely populated area. For the same reasons, assuring safety after cleaning decontaminated sites can be challenging. Currently available technologies require considerable labor, and results typically cannot be obtained before 24 V 48 hours up ...

    SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense
  6. Ruggedized FTIR Spectrometer Based on Calomel Prisms

    SBC: AGILTRON, INC.            Topic: CBD11104

    Leveraging on Agiltron industry leading development of optical systems and the PI experience with FTIR spectrometer design, we propose to develop a new class of compact monolithic Fourier-transform spectrometers for the long-wave (7.5-13 m) infrared optical range. The proposed solution is based on creating a spatial interferogram with a pair of a calomel Wollaston prisms and digitizing it with an ...

    SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense
  7. Low noise longwave infrared (8-12µm) focal plane array with high sensitivity for passive hyperspectral standoff detection

    SBC: APPLIED NANOFEMTO TECHNOLOGIES LLC            Topic: CBD10105

    Longwave infrared (LWIR, 8-12µm) focal plane arrays (FPAs) play an important role in hyperspectral chemical and biological (CB) sensing and spectral imaging. Existing thermal detectors are unable to meet the high sensitivity and fast response requirements of many hyperspectral chemical and biological sensing applications. FPAs based on photon excited electron generation process can fulfill the sp ...

    SBIR Phase II 2011 Department of DefenseOffice for Chemical and Biological Defense
  8. MEMS Lamellar Based Interferometer for the Detection of Toxic Chemicals

    SBC: AGILTRON, INC.            Topic: CBD10104

    Leveraging on Agiltron industry leading development of optical MEMS devices and the PI experience with FTIR spectrometer design, we propose to develop a new class of high performance compact and rugged FTIR spectrometers for the LWIR optical range. The design is based on the MEMS lamellar mirror technique. Although this approach is not new, it has not yet been efficiently applied to LWIR, and per ...

    SBIR Phase II 2011 Department of DefenseOffice for Chemical and Biological Defense
  9. Construction of a Force Probe for Characterization of Microscale Features

    SBC: INSITUTEC, INC.            Topic: N/A

    The Phase 2 objective is to provide NIST with a modular gauge head unit equipped with InsituTec's standing wave probe technology. The complete gauge head unit will be retrofitted to the NIST M48 which is one of the most precise measuring machines in the world. This unit will enable NIST to achieve the agency's program goal in dimensional metrology which is to provide microscale measurement capacit ...

    SBIR Phase II 2006 Department of CommerceNational Institute of Standards and Technology
  10. Handheld FT-IR/Photoacoustic Chemical Agent Detector

    SBC: MANNING APPLIED TECHNOLOGY            Topic: CBD05112

    Manning Applied Technology proposes development of the MP-100 handheld FT-infrared photoacoustic chemical agent detector, following a highly successful Phase I effort. Chemical attacks and accidents can be mitigated partially by cost-effective sensors. High priority programs will benefit from a sensor compliant to Joint Warning & Reporting Network (JWARN) standards. The device is ideally suited to ...

    SBIR Phase II 2006 Department of DefenseOffice for Chemical and Biological Defense
US Flag An Official Website of the United States Government