  1. Narrowband Perfect Absorber using Metamaterials

    SBC: PHOEBUS OPTOELECTRONICS LLC            Topic: CBD11102

    We propose a metamaterial-enhanced microbolometer with strong absorption over a narrow band that is dynamically tunable over the 8-10 micron band. A single-layer photonic metamaterial consisting of a thin metal film perforated with a 2-D array of dielectric apertures will be deposited on an amorphous-Silicon layer acting as an absorber and bolometer. The metamaterial, in conjunction with planar di ...

    SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense
  2. Multiplex Microsphere Assay for Botulinum Neutralizing Antibodies

    SBC: AGAVE BIOSYSTEMS INC.            Topic: CBD11109

    Currently, the accepted standard experimental model for measuring protective efficacy against botulism is the Mouse Lethality Neutralization (MLN) assay. Botulism poisoning is a life threatening condition that is not only a public health concern, but could also be a potential biological weapon. With seven serotypes of botulinum neurotoxins, there is need for an alternative to the MLN assay due t ...

    SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense
  3. A High-Throughput Blood Esterase Panel Assay

    SBC: AGAVE BIOSYSTEMS INC.            Topic: CBD10108

    Organophosphorus chemical warfare nerve agents (OP-CWA) are attractive to terrorist groups and rogue states as an inexpensive and accessible technology for chemical warfare. OP-CWA and organophosphate pesticides cause severe neurological symptoms and death by inhibiting the enzyme acetylcholinesterase (AChE); the resulting excess acetylcholine accumulates and overstimulates the human or animal bo ...

    SBIR Phase II 2011 Department of DefenseOffice for Chemical and Biological Defense
  4. Analysis Tools for Detection and Diagnosis of Biological Threats

    SBC: ALPHA-GAMMA TECHNOLOGIES, INC.            Topic: CBD04113

    DNA microarray technology, in combination with statistical and predictive modeling tools, could be used to evaluate thousands of genes against distinct gene expression patterns induced by chemical/biological agents to provide early identification and speed therapeutic intervention. The overall objective of this Phase II effort is to leverage existing public domain resources and commercial tools t ...

    SBIR Phase II 2005 Department of DefenseOffice for Chemical and Biological Defense
  5. Handheld Photoacoustic Chemical Agent and Toxic Industrial Material Detector

    SBC: MANNING APPLIED TECHNOLOGY            Topic: CBD05112

    Manning Applied Technology proposes to develop a handheld infrared spectrometer, ideally suited to detection of airborne chemical agents at and below permissible exposure limits. This approach offers unmatched sensitivity and specificity for detection of all types of chemical vapors. The instrument is modular, rugged, compact and highly sensitive. Volume pricing will be less than $1000 each. ...

    SBIR Phase I 2005 Department of DefenseOffice for Chemical and Biological Defense
  6. Hermetic Textile Closure Hardware System

    SBC: SIGMA K CORP            Topic: CBD04110

    Effective collective protection fabrics must have a reliable closure system. During our Phase I Work Plan, Sigma-K began developing a Hermetic Textile Closure Hardware (HATCH) system. The HATCH combines both a magnetic and geometric self locking mechanism that will provide a hermetic seal when closed. Our current Phase I successes include developing self closing samples that can provide a hermetic ...

    SBIR Phase II 2005 Department of DefenseOffice for Chemical and Biological Defense