Narrowband Perfect Absorber using Metamaterials
SBC: PHOEBUS OPTOELECTRONICS LLC Topic: CBD11102We propose a metamaterial-enhanced microbolometer with strong absorption over a narrow band that is dynamically tunable over the 8-10 micron band. A single-layer photonic metamaterial consisting of a thin metal film perforated with a 2-D array of dielectric apertures will be deposited on an amorphous-Silicon layer acting as an absorber and bolometer. The metamaterial, in conjunction with planar di ...
SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense -
Improved M8 Chemical Agent Detector Paper for Facilities Monitoring
SBC: Orono Spectral Solutions Inc. Topic: CBD11103The goal of this Phase I project is to develop coatings for M8 paper that improve its robustness and rate of detection of potential liquid/aerosol chemical warfare attack at fixed military sites and installations. A problem that is currently experienced with M8 paper is that it is easily contaminated by dust or destroyed by rain and thus requires frequent replacement in outdoor environments. Our ...
SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense -
Multiplex Microsphere Assay for Botulinum Neutralizing Antibodies
SBC: AGAVE BIOSYSTEMS INC. Topic: CBD11109Currently, the accepted standard experimental model for measuring protective efficacy against botulism is the Mouse Lethality Neutralization (MLN) assay. Botulism poisoning is a life threatening condition that is not only a public health concern, but could also be a potential biological weapon. With seven serotypes of botulinum neurotoxins, there is need for an alternative to the MLN assay due t ...
SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense -
A High-Throughput Blood Esterase Panel Assay
SBC: AGAVE BIOSYSTEMS INC. Topic: CBD10108Organophosphorus chemical warfare nerve agents (OP-CWA) are attractive to terrorist groups and rogue states as an inexpensive and accessible technology for chemical warfare. OP-CWA and organophosphate pesticides cause severe neurological symptoms and death by inhibiting the enzyme acetylcholinesterase (AChE); the resulting excess acetylcholine accumulates and overstimulates the human or animal bo ...
SBIR Phase II 2011 Department of DefenseOffice for Chemical and Biological Defense