  1. Narrowband Perfect Absorber using Metamaterials

    SBC: PHOEBUS OPTOELECTRONICS LLC            Topic: CBD11102

    We propose a metamaterial-enhanced microbolometer with strong absorption over a narrow band that is dynamically tunable over the 8-10 micron band. A single-layer photonic metamaterial consisting of a thin metal film perforated with a 2-D array of dielectric apertures will be deposited on an amorphous-Silicon layer acting as an absorber and bolometer. The metamaterial, in conjunction with planar di ...

    SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense
  2. Narrowband Perfect Absorber using Metamaterials

    SBC: LUMILANT, INC.            Topic: CBD11102

    Hyperspectral imaging systems acquire the spatial and spectral information of the image scene simultaneously, and thus find important applications in remote sensing, military surveillance, and target identification. Most contemporary hyperspectral imaging systems operate at UV/VIS/NIR (ultra violet/visible/near infrared) spectrums. However, in many cases, especially in military applications, (hype ...

    SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense
  3. Compact Solid State Deep Ultraviolet (UV) laser for Raman detection of CB agents

    SBC: SNAKE CREEK LASERS LLC            Topic: CBD11105

    This topic addresses the need for compact efficient solid-state deep ultraviolet (UV) lasers operating in the wavelength range of 220-250 nm, for use in Raman systems for chemical and biological detection. The laser to be developed would also be very useful in the detection of explosives. We propose to develop an efficient 946 Q-switched nm laser system that is efficiently quadrupled to 236.5 nm. ...

    SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense
  4. Compact Piezoelectric High Intensity Sound Source

    SBC: Omega Piezo Technologies            Topic: CBD11108

    There is a market need for high intensity sound sources that can operate for long durations over wide temperature ranges and in environments with dust and humidity exposure. Piezoelectric sound sources offer many advantages over compression drivers in these applications. They can be small and lightweight, have low power consumption, operate in narrow frequency bands, and can achieve a high sound p ...

    SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense
  5. Robust Piezoelectric Sound Source with Helmholtz Acoustic Amplification

    SBC: KCF TECHNOLOGIES, INC.            Topic: CBD11108

    KCF Technologies proposes to develop a robust and efficient sound generator for separation/isolation of aerosols. The critical limitations in the performance of conventional piezoelectric sound generators include degradation in performance over long periods of operation, poor electro-acoustic efficiencies at high amplitude drive levels, and large tolerances in their acoustic performance. These pro ...

    SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense
  6. Multiplex Microsphere Assay for Botulinum Neutralizing Antibodies

    SBC: AGAVE BIOSYSTEMS INC.            Topic: CBD11109

    Currently, the accepted standard experimental model for measuring protective efficacy against botulism is the Mouse Lethality Neutralization (MLN) assay. Botulism poisoning is a life threatening condition that is not only a public health concern, but could also be a potential biological weapon. With seven serotypes of botulinum neurotoxins, there is need for an alternative to the MLN assay due t ...

    SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense
  7. A High-Throughput Blood Esterase Panel Assay

    SBC: AGAVE BIOSYSTEMS INC.            Topic: CBD10108

    Organophosphorus chemical warfare nerve agents (OP-CWA) are attractive to terrorist groups and rogue states as an inexpensive and accessible technology for chemical warfare. OP-CWA and organophosphate pesticides cause severe neurological symptoms and death by inhibiting the enzyme acetylcholinesterase (AChE); the resulting excess acetylcholine accumulates and overstimulates the human or animal bo ...

    SBIR Phase II 2011 Department of DefenseOffice for Chemical and Biological Defense
  8. Collective Protection for Military Working Dogs

    SBC: AGAVE BIOSYSTEMS INC.            Topic: CBD08103

    Shelter enclosures for military working dogs in the event of a CB attack is a technology gap identified by the Joint Requirements Office. Important parameters to consider in the design of protective enclosures include low weight and size to minimize transport requirements; rapid setup; and accommodation of canine physiological and psychological comfort needs while providing protection against CB ...

    SBIR Phase II 2009 Department of DefenseOffice for Chemical and Biological Defense
  9. Bio-Inspired Dry Fibrillar Adhesives for Enhanced Sealing of Respiratory Protective Masks

    SBC: NANOGRIPTECH            Topic: CBD09102

    NanoGriptech LLC proposes to develop repeatable skin adhesives using technology inspired by the feet of geckos and insects. These adhesives will be integrated into full facemask respirators to reduce or replace head harness straps, which are currently used to hold the facemasks in place. Expected benefits are improved fit, resistance to shifting, improved sealing, and reduced discomfort and tiss ...

    SBIR Phase I 2009 Department of DefenseOffice for Chemical and Biological Defense
  10. Distributed Thermal Imaging Spectrometer for Force Protection

    SBC: MESH INC            Topic: CBD09108

    This proposal describes how a very low cost hyperspectral imager can be built. The key to the low cost is the use of a commercially available thermal camera based on uncooled microbolometer as the detecting element. An interferometer is placed in front of the camera to produce the spectrum. Each frame of the camera captures one point of the interferogram, producing a hyperspectral image at 4cm- ...

    SBIR Phase I 2009 Department of DefenseOffice for Chemical and Biological Defense