You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. Narrowband Perfect Absorber using Metamaterials

    SBC: PHOEBUS OPTOELECTRONICS LLC            Topic: CBD11102

    We propose a metamaterial-enhanced microbolometer with strong absorption over a narrow band that is dynamically tunable over the 8-10 micron band. A single-layer photonic metamaterial consisting of a thin metal film perforated with a 2-D array of dielectric apertures will be deposited on an amorphous-Silicon layer acting as an absorber and bolometer. The metamaterial, in conjunction with planar di ...

    SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense
  2. Narrowband Perfect Absorber using Metamaterials

    SBC: LUMILANT, INC.            Topic: CBD11102

    Hyperspectral imaging systems acquire the spatial and spectral information of the image scene simultaneously, and thus find important applications in remote sensing, military surveillance, and target identification. Most contemporary hyperspectral imaging systems operate at UV/VIS/NIR (ultra violet/visible/near infrared) spectrums. However, in many cases, especially in military applications, (hype ...

    SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense
  3. Multiplex Microsphere Assay for Botulinum Neutralizing Antibodies

    SBC: AGAVE BIOSYSTEMS INC.            Topic: CBD11109

    Currently, the accepted standard experimental model for measuring protective efficacy against botulism is the Mouse Lethality Neutralization (MLN) assay. Botulism poisoning is a life threatening condition that is not only a public health concern, but could also be a potential biological weapon. With seven serotypes of botulinum neurotoxins, there is need for an alternative to the MLN assay due t ...

    SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense
  4. A High-Throughput Blood Esterase Panel Assay

    SBC: AGAVE BIOSYSTEMS INC.            Topic: CBD10108

    Organophosphorus chemical warfare nerve agents (OP-CWA) are attractive to terrorist groups and rogue states as an inexpensive and accessible technology for chemical warfare. OP-CWA and organophosphate pesticides cause severe neurological symptoms and death by inhibiting the enzyme acetylcholinesterase (AChE); the resulting excess acetylcholine accumulates and overstimulates the human or animal bo ...

    SBIR Phase II 2011 Department of DefenseOffice for Chemical and Biological Defense
  5. Low-Output High Precision Automated Powder Disseminator

    SBC: ADVANCED MECHANICAL SYSTEMS TECHNOLOGY,            Topic: CBD06101

    This proposal presents a Phase II SBIR project to produce prototypes of the automated high precision, low disperse rate powder disseminator for the US Army, that has been successfully designed and analyzed in the Phase I project. In the development of the sensitive detecting agent, we need to release a precise amount of C&B agents in the controlled detection experiments. At the end of this Phase ...

    SBIR Phase II 2007 Department of DefenseOffice for Chemical and Biological Defense
  6. Low-Output High Precision Automated Powder Disseminator

    SBC: ADVANCED MECHANICAL SYSTEMS TECHNOLOGY,            Topic: CBD06101

    This proposal presents a Phase I SBIR project to develop a high precision, low disperse rate powder disseminator for the US Army. In the development of the sensitive detecting agent, we need to release a precise amount of C&B agents in the controlled detection experiments. However, such a technology does not exist at the present time. After examining existing technologies, we believe that the r ...

    SBIR Phase I 2006 Department of DefenseOffice for Chemical and Biological Defense
  7. Handheld FT-IR/Photoacoustic Chemical Agent Detector

    SBC: MANNING APPLIED TECHNOLOGY            Topic: CBD05112

    Manning Applied Technology proposes development of the MP-100 handheld FT-infrared photoacoustic chemical agent detector, following a highly successful Phase I effort. Chemical attacks and accidents can be mitigated partially by cost-effective sensors. High priority programs will benefit from a sensor compliant to Joint Warning & Reporting Network (JWARN) standards. The device is ideally suited to ...

    SBIR Phase II 2006 Department of DefenseOffice for Chemical and Biological Defense
US Flag An Official Website of the United States Government