Production Methods and Software for NIST Calibration Phantoms
SBC: SIGMA K CORP Topic: 9050868TTCurrently, there are over 10,000 MRI scanners used in the US alone. US citizens today are mobile and many times medical treatments may require MRI scans from several different facilities. Images from MRI scanners can also drift over time. There is a tremendous need for all medical imaging scanners to be on the same level. Sigma-K will develop the commercialization of the ISMRM/NIST MRI Calibration ...
SBIR Phase I 2011 Department of CommerceNational Institute of Standards and Technology -
Improved M8 Chemical Agent Detector Paper for Facilities Monitoring
SBC: Orono Spectral Solutions Inc. Topic: CBD11103The goal of this Phase I project is to develop coatings for M8 paper that improve its robustness and rate of detection of potential liquid/aerosol chemical warfare attack at fixed military sites and installations. A problem that is currently experienced with M8 paper is that it is easily contaminated by dust or destroyed by rain and thus requires frequent replacement in outdoor environments. Our ...
SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense -
Analysis Tools for Detection and Diagnosis of Biological Threats
SBC: ALPHA-GAMMA TECHNOLOGIES, INC. Topic: CBD04113DNA microarray technology, in combination with statistical and predictive modeling tools, could be used to evaluate thousands of genes against distinct gene expression patterns induced by chemical/biological agents to provide early identification and speed therapeutic intervention. The overall objective of this Phase II effort is to leverage existing public domain resources and commercial tools t ...
SBIR Phase II 2005 Department of DefenseOffice for Chemical and Biological Defense -
Construction of a Force Probe for Characterization of Microscale Features
SBC: INSITUTEC, INC. Topic: N/AThe pressing need exists within industry to accurately measure high aspect ratio microscale structures. For example, diesel injector nozzles are manufactured with microscale holes ranging from 50-200 micrometers in diameter and 3-5 mm depths. One fundamental challenge is to nondestrucvely measure these features in order to validate models, enhance manufacturing processes, and reduce fuel emissions ...
SBIR Phase I 2005 Department of CommerceNational Institute of Standards and Technology -
Autonomous, Unattended, Reagentless Biological Agent Detector
SBC: Orono Spectral Solutions Inc. Topic: CBD05111The goal of this project is to investigate the feasability of a unique sampling method that will lead to the development of a reagentless infrared (IR) based BW agent detection system. The current JPBDS uses lateral flow immunoassay technology as the final step in detecting bioagents, and has a detection limit of 10^5 spores/ml[ref 1]. Preliminary data from our infrared approach indicates a mini ...
SBIR Phase I 2005 Department of DefenseOffice for Chemical and Biological Defense -
Hermetic Textile Closure Hardware System
SBC: SIGMA K CORP Topic: CBD04110Effective collective protection fabrics must have a reliable closure system. During our Phase I Work Plan, Sigma-K began developing a Hermetic Textile Closure Hardware (HATCH) system. The HATCH combines both a magnetic and geometric self locking mechanism that will provide a hermetic seal when closed. Our current Phase I successes include developing self closing samples that can provide a hermetic ...
SBIR Phase II 2005 Department of DefenseOffice for Chemical and Biological Defense -
Tool Condition Monitoring and Diagnostics
SBC: VulcanCraft Topic: N/AA smart machine tool must be able to monitor its condition and report problems. Every CNC machine should provide an alarm for tool condition problems, including tool wear, much as every automobile has a low oil indicator. Tool wear is particularly important for unattended machining as a worn tool can ruin a part. All current tool condition systems operate "blind" without direct information on curr ...