You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. A SELF-DISCOVERING WIRELESS NETWORK FOR MEDICAL DEVICES

    SBC: ADVANCED MEDICAL ELECTRONICS CORP            Topic: N/A

    DESCRIPTION (provided by applicant): Advanced Medical Electronics Corporation (AME) proposes to implement a self-discovering wireless connectivity network for portable medical devices used in emergency applications. A self-discovering local wireless network is a communications scheme in which devices within a certain area establish connections to one another without requiring user intervention. A ...

    SBIR Phase II 2002 Department of Health and Human ServicesNational Institutes of Health
  2. VIDEO POLYSOMNOGRAPH FOR HOME SLEEP TESTS VIA PHONE LINE

    SBC: ADVANCED MEDICAL ELECTRONICS CORP            Topic: N/A

    N/A

    SBIR Phase II 2002 Department of Health and Human ServicesNational Institutes of Health
  3. TREATMENT OF AIDS-RELATED ORAL CANDIDIASIS

    SBC: Advanced Photodynamic Technologies, Inc.            Topic: N/A

    N/A

    SBIR Phase II 2002 Department of Health and Human ServicesNational Institutes of Health
  4. A HOMOGENEOUS TRANSMIT COIL FOR HIGH FIELD HUMAN NMR

    SBC: BIOENGINEERING, INC.            Topic: N/A

    DESCRIPTION (provided by applicant): In this Phase II STTR project, the investigators plan to extend their successful Phase I feasibility demonstration to the development and manufacture of an RF body coil plus phased array receive system for use in high field clinical and research MRI systems. In Phase I, the feasibility of a large homogeneous transmit coil based on the TEM design was proven, pub ...

    STTR Phase II 2002 Department of Health and Human ServicesNational Institutes of Health
  5. INEXPENSIVE HEARING DEVICE BASED ON EAR CANAL GEOMETRY

    SBC: HEARING COMPONENTS, INC.            Topic: N/A

    DESCRIPTION: We believe there is a need for a high quality inexpensive " reading glasses for your ears" device. This starter device would allow extreme large number of entry-level hearing loss people to experience hearing help earlier. ...

    SBIR Phase II 2002 Department of Health and Human ServicesNational Institutes of Health
  6. ADMINISTRATION AND MANAGEMENT OF PORTABLE ELECTRONIC FORMS IN CLINICAL ENVIRO

    SBC: INFOTECH SOFT, INC.            Topic: N/A

    N/A

    SBIR Phase II 2002 Department of Health and Human ServicesNational Institutes of Health
  7. RAPID, SINGLE MOLECULAR DNA SEQUENCING NANOPORE DEVICE

    SBC: ADVANCED RESEARCH CORPORATION            Topic: N/A

    DESCRIPTION (provided by applicant): The objective of this Phase II program is to complete the development of a commercializable solid state nanopore device for the accurate high speed sequencing of DNA. To achieve this goal a manufacturable device must be designed and fabrication processes established that result in a unit with extremely small, well controlled diameter orifices of approximately 2 ...

    SBIR Phase II 2002 Department of Health and Human ServicesNational Institutes of Health
  8. OTIC PROBE FOR NEUROCOCHLEAR INTRAOPERATIVE MONITORING

    SBC: INTELLIGENT HEARING SYSTEMS CORP            Topic: N/A

    DESCRIPTION (provided by applicant): Many cases of sensorineural hearing loss (SNHL) likely are caused by interruption of cochlear blood flow (CBF). Disruption of the internal auditory artery during surgical procedures to remove acoustic neuromas (ANs) probab'y account for many cases of postoperative deafness. Also, many cases of clinical SNHL, such as sudden SNHL, are thought to involve reductio ...

    SBIR Phase II 2002 Department of Health and Human ServicesNational Institutes of Health
  9. OXALOBACTER FORMIGENES DIAGNOSTIC KIT DEVELOPMENT

    SBC: IXION BIOTECHNOLOGY, INC.            Topic: N/A

    DESCRIPTION (provided by applicant): Absence of Oxalobacter formigenes (Oxf) from the GI-tract is a risk factor for development of hyperoxaluria and calcium oxalate kidney stones. Recent data now indicate that patients with recurrent urolithiasis have a lower prevalence rate of Oxf in their stools than non-stone forming individuals. In addition, urinary oxalate levels are higher in non-colonized i ...

    SBIR Phase II 2002 Department of Health and Human ServicesNational Institutes of Health
  10. M3 RECEPTOR--DIAGNOSTIC MARKER FOR SJOGREN'S SYNDROME

    SBC: IXION BIOTECHNOLOGY, INC.            Topic: N/A

    DESCRIPTION (provided by applicant): Sjogren's syndrome is a human autoimmune disease of the salivary and lacrimal glands that results in a debilitating xerostomia (dry mouth) and xerophthalmia (dry eyes). This syndrome may present as either a primary autoimmune disease or as a secondary autoimmune disease most often concomitant with other connective tissue diseases or diabetes. Although classi ...

    STTR Phase II 2002 Department of Health and Human ServicesNational Institutes of Health
US Flag An Official Website of the United States Government