You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. Reactive Nanoparticles as Destructive Adsorbents for Biolog

    SBC: NanoScale Materials, Inc.            Topic: N/A

    The objective of this Phase I is to demonstrate the use of Reactive Nanoparticles (RNP) for the decontamination/sterilization of biological agents and their mimics. Recent studies have shown that RNPs are very effective for chemical agent decontamination at ambient or higher temperature. Examples include paraoxon, VX, half mustard and HD. RNPs themselves are generally made of non-toxic magnesiu ...

    STTR Phase I 1998 Department of DefenseDefense Advanced Research Projects Agency
  2. Advanced Piezoelectric-Positioner Controller for High-Speed Scanning Probe Microscopy

    SBC: PIEZOMAX TECHNOLOGIES, INC.            Topic: N/A

    This SBIR Phase I project will investigate the feasibility of an improved control strategy for piezoelectric positioners used in scanned-probe microscopes (SPMs) to increase their speed and reliability for nanocharacterization. Rapid nanocharacterization requires fast motion of the scanned piezo probe with sub-Angstrom vertical resolution and with frequent rapid changes in its axial position. Se ...

    SBIR Phase II 1998 Department of DefenseDefense Advanced Research Projects Agency
  3. Applications and Methods for Continuous Monitoring of Physiological Chemistry

    SBC: Pinnacle Technology, Inc.            Topic: SB12A003

    With the notable exception of glucose, most metabolic biomarkers cannot be accurately, and practically measured over long periods, in vivo and in real-time. A primary reason is stable, selective enzymes suitable for biosensors are not available. Biosensors could revolutionize acute and long-term monitoring in the development, clinical, first responder and battlefield arenas. Pinnacle has develo ...

    STTR Phase I 2012 Department of DefenseDefense Advanced Research Projects Agency
  4. Biometrics-at-a-distance

    SBC: OMNEVIA CORPORATION            Topic: SB121004

    The DOD has a need to leverage state of the art technologies remotely detect, collect, and evaluate physiological signals of interest. Applications and concepts-of-operations (CONOPs) that would benefit from this capability include, but are not limited to: building-clearing, warfighter health monitoring or battle damage assessment and triage, situational awareness and assessment. The main goal o ...

    SBIR Phase I 2012 Department of DefenseDefense Advanced Research Projects Agency
  5. Machine Tool Genome Project

    SBC: MANUFACTURING LABORATORIES, INC.            Topic: SB102005

    The objective of this research is to enable pre-process milling parameter selection for"first part correct"production. In the proposed solution the Receptance Coupling Substructure Analysis (RCSA) approach will be used to couple the measured spindle-machine dynamics to models of the tool and holder and predict the assembly"s dynamic response. Given this information, frequency/time-domain algorithm ...

    SBIR Phase II 2012 Department of DefenseDefense Advanced Research Projects Agency
  6. Direct Plasma Production from Electric Solid Propellant for High Velocity Launch Systems

    SBC: Digital Solid State Propulsion, Inc            Topic: SB112002

    As an alternative to near-obsolete double-base or triple-base propellants, Digital Solid State Propulsion (DSSP) is developing Electric Solid Propellants (ESP) as a safe, green, higher performance highly manufacturable alternative for high velocity electro-thermal-chemical (ETC) gun rounds. These electric energetic materials are inherently safe, with ignition only possible via the sustained suppl ...

    SBIR Phase II 2012 Department of DefenseDefense Advanced Research Projects Agency
  7. Integrated, self-actuated, blood collection and biomarker purification device

    SBC: Tasso, Inc            Topic: SB122003

    Blood-based assays require upstream mechanisms to acquire sample from a patient, extract the analyte of interest, and preserve the analyte until it can be quantified. Current point-of-care assays overwhelmingly rely on lancet puncture, which is inconvenient because of the presence of blood that is open to the environment and induces high levels of user error inherent with the multiple steps requir ...

    SBIR Phase I 2013 Department of DefenseDefense Advanced Research Projects Agency
US Flag An Official Website of the United States Government