You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. Direct Blood Volume Analyzer for Improvement of Combat Casualty Care

    SBC: DAXOR CORPORATION            Topic: A18122

    Hemorrhage is the leading cause of preventable combat mortality. Despite recent advances in care, sustaining adequate tissue perfusion remains a challenge. Current practice for determining fluid status to guide battlefield resuscitation and transfusion, including clinical assessment and surrogate markers, often lag symptomatic diagnosis or misdiagnose the severity of volume derangement. Care is fu ...

    SBIR Phase II 2023 Department of DefenseDefense Health Agency
  2. Biosensor and Controller for Closed Loop Anesthesia Delivery System

    SBC: Infusense            Topic: DHP12012

    Microfabricated chemical and biological sensors serve as an interface between biologic and electronic systems. Previously, through TATRC-funded research grants (W81XWH-05-2-0064, W81XWH-10-1-0358), we have investigated the behavior and detection of propofol using electrochemical (EC) methods. Using these analytical methods, we have quantified the oxidation of propofol well below therapeutic concen ...

    SBIR Phase I 2013 Department of DefenseDefense Health Agency
  3. Parallel Kinematic Actuator with Reduced Size and Improved Performance

    SBC: DYNAMIC STRUCTURES AND MATERIALS, LLC            Topic: OSD09H09

    Applications for ultrasound are expanding beyond medical imaging to include new functionality, with the potential to halt internal bleeding or provide an alternative to manual suturing. These types of functions are suited to a surgical robot, offering the potential for tele-operation or even autonomous functionality. However, the requirements for positioning an ultrasound device are different th ...

    SBIR Phase II 2011 Department of DefenseDefense Health Agency
US Flag An Official Website of the United States Government