You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. TheSieve

    SBC: CYBER POINT INTERNATIONAL LLC            Topic: None

    CyberPoint International presents the design of a cross platform product for the autonomous execution of live forensic investigations of Personal Computers, Laptops and Servers leveraging the NIST NSRL corpus and a combination of at least 3 forms of machine learning/artificial intelligent algorithms for the processing of preliminary digital evidence titled TheSieve. We build upon work from our pha ...

    SBIR Phase II 2019 Department of CommerceNational Institute of Standards and Technology
  2. Multimode Chiroptical Spectrometer for Nanoparticle Characterization

    SBC: APPLIED NANOFLUORESCENCE, LLC            Topic: None

    This project will develop a new scientific instrument optimized for the advanced characterization of near-infrared fluorescent nanoparticles that can exist as left- or right-handed structures (enantiomers). Single-walled carbon nanotubes (SWCNTs) are the leading current example of such nanomaterials. Applied NanoFluorescence, LLC (ANF) proposes a novel multi-mode chiroptical spectrometer that can ...

    SBIR Phase II 2019 Department of CommerceNational Institute of Standards and Technology
  3. Developing Commercial Quantum Resistance Standard Based on Epitaxial Graphene

    SBC: GRAPHENE WAVES, LLC            Topic: None

    Graphene Waves proposes to develop a quantum Hall resistance (QHR) standard based on graphene that can be deployed for general electrical calibration in industries. Current QHR standard is based on GaAs/AlGaAs heterostructure and requires expensive liquid helium to operate. The continuous increase in price and unstable supply chain of liquid helium limit the QHR standard to be only affordable by t ...

    SBIR Phase I 2019 Department of CommerceNational Institute of Standards and Technology
  4. Laser Particle Separation

    SBC: Opthos Instrument Company, LLC            Topic: None

    Parman Tech is dedicated to commercializing a NIST technology for sorting nano-particles. This technology uses the force of light to gently guide particles along different paths depending on the size of makeup of each particle.

    SBIR Phase I 2019 Department of CommerceNational Institute of Standards and Technology
  5. Gap-Free Model-Based Engineering for Manufacturing and Analysis: Digital Thread without Translation

    SBC: Nvariate, Inc.            Topic: None

    Modern Model-Based Enterprise / Engineering (MBE) systems rely on freeform surfaces built as complex combinations of geometric primitives to define engineered objects. Unfortunately, the intersection of freeform surfaces in MBE applications results in highly approximated solutions, degrading models that cost billions annually by US industry to fix. Current technology limits the abilities of users ...

    SBIR Phase I 2019 Department of CommerceNational Institute of Standards and Technology
  6. Advanced Manufacturing and Material Measurements Software Tool Weave ™ for the Acceleration and Automation of SEM Image Analysis in the Semiconductor Industry

    SBC: Sandbox Semiconductor Incorporated            Topic: None

    In this Phase I SBIR proposal, SandBox Semiconductor™ proposes to develop an Advanced Manufacturing and Material Measurements software tool called Weave ™ for accelerating and automating SEM image analysis for the semiconductor industry. During the development of a new manufacturing process line for a semiconductor device, tens of thousands of scanning electron microscopy (SEM) images are take ...

    SBIR Phase I 2019 Department of CommerceNational Institute of Standards and Technology
  7. High-Throughput Low-Cost Manufacturing of Engineered MRI Contrast Agents

    SBC: WEINBERG MEDICAL PHYSICS, INC.            Topic: 90103

    New shape-engineered iron-based microscopic contrast agents (MCAs) for magnetic resonance imaging promise to increase diagnostic accuracy while reducing side effects, and enhance scientists’ ability to track stem cells. Currently, techniques used for making multispectral microscale contrast agent particles are cost prohibitive. In Phase I, an innovative technique (employing template-guided elect ...

    SBIR Phase II 2016 Department of CommerceNational Institute of Standards and Technology
  8. Resonant Scan Lens for Scanning Beam LIDAR

    SBC: z-senz LLC            Topic: 90501

    The objective of this Phase II project is to research, develop, and commercialize a resonant scan lens (RSL) for use in a resonant light detection and ranging (R-LIDAR) distance sensor. R-LIDAR uses a resonant optomechanical system to generate a beam scan. While resonant optomechanical systems produce high-speed and large field-of-view (FOV) scans from a miniature form factor, the beam scans lack ...

    SBIR Phase II 2016 Department of CommerceNational Institute of Standards and Technology
  9. Nanometer Precision Absolute Linear Interferometer

    SBC: AUTOMATED PRECISION, INC.            Topic: 090101

    The goal of this Phase I project is to develop an affordable, accurate, and rapid absolute interferometric length measurement technique with improved repeatability and accuracy. API has a patent-pending technology, Frequency-Modulated Time-to-Frequency Mapping Interferometer (FM-TFMI), that is an absolute interferometer capable of measuring at high speed and with exceptionally high accuracy. The T ...

    SBIR Phase I 2016 Department of CommerceNational Institute of Standards and Technology
  10. Fiber Pigtailed On-Chip Mid-infrared Difference Frequency Generation in Silicon

    SBC: OMEGA OPTICS, INC.            Topic: 90102

    Omega Optics will develop a fiber-coupled platform in strained silicon-on-sapphire (SoS) for tunable difference frequency generation in midwave infrared (MIR) with tunable continuous wave sources in the near-infrared (NIR). Stress exerted by silicon nitride on underlying silicon induces second-order nonlinear susceptibility. NIR light is coupled into silicon and MWIR light is coupled out of silico ...

    SBIR Phase I 2016 Department of CommerceNational Institute of Standards and Technology
US Flag An Official Website of the United States Government