You are here
Award Data
The Award database is continually updated throughout the year. As a result, data for FY22 is not expected to be complete until September, 2023.
Download all SBIR.gov award data either with award abstracts (290MB)
or without award abstracts (65MB).
A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.
-
Acoustically/Vibrationally Enhanced High Frequency Electromagnetic Detector for Buried Landmines
SBC: White River Technologies Inc Topic: A16AT004White River Technologies, Inc. (WRT) and University of Vermont (UVM) present this proposal, "Acoustically/Vibrationally Enhanced High Frequency Electromagnetic Detector for Buried Landmines". Among the primary gaps in our current landmine detection technology base is the ability to detect a wide range of buried explosive hazards including emerging low-metal mines and improvised explosive devices ...
STTR Phase I 2016 Department of DefenseArmy -
Big Open Source Social Science (BOSSS)
SBC: BOSTON FUSION CORP Topic: A16AT013Boston Fusion Corp. and Arizona State University propose to research and develop Big Open Source Social Science (BOSSS). In BOSSS, we will create a unified approach that combines social and computer science methodologies to collect and interpret big open source data, yielding meaningful focused analysis of selected populations. We will develop a system framework that adaptively learns social behav ...
STTR Phase I 2016 Department of DefenseArmy -
Miniature Mass Spectrometer for Peptide Sequencing and Mobile Coupling with Separation Techniques
SBC: BAYSPEC, INC. Topic: A16AT012Using advanced ion optics that was developed by Pacific Northwest National Laboratory (PNNL), BaySpec will develop a prototype of portable mass spectrometer (less than 40 lb. and 300W) with continuous atmospheric pressure inlet that is fully capable of uninterrupted on-line sampling from an ambient environment. The continuous nature of the inlet ensures full compatibility with separation technique ...
STTR Phase I 2016 Department of DefenseArmy -
Technologies to Target Circadian Rhythm Disruption in PTSD
SBC: BIOSENSICS LLC Topic: A16AT014Circadian rhythm disruption misalignment causes fatigue and a variety of physical and mental ailments, and is a clinical feature of posttraumatic stress disorder (PTSD); it is also closely linked to the severity of PTSD. BioSensics, in collaboration with the Division of Sleep and Circadian Disorders at Brigham and Womens Hospital, will develop a circadian rhythm and sleep coach, Rhythm Sleep, to m ...
STTR Phase I 2016 Department of DefenseArmy -
Detecting Substandard, Nonconforming, Improperly Processed and Counterfeit Materiel
SBC: Ocean Bay Information and Systems Management, LLC Topic: DLA15C001"Micro-calorimetry is a Nondestructive Test (NDT) capable of detecting heat characteristics that could identify improperly processed, counterfeit, substandard, nonconforming or fake raw material prior to materials introduction into end-product production cycles. Current calorimetric technology is an extremely sensitive, expensive and time consuming process, utilizing an adiabatic or semi-adiabat ...
STTR Phase I 2016 Department of DefenseDefense Logistics Agency -
Using Magnetic Levitation for Non-Destructive Detection of Defective and Counterfeit Materiel
SBC: Nano Terra, Inc. Topic: DLA15C001The introduction of substandard or counterfeit materials into the DoD supply chain can have extremely expensive, and potentially life threatening, consequences. Current techniques used to detect nonconforming materiel can be destructive (e.g., manual sectioning and inspection of a part), time consuming and expensive (e.g., micro-computed tomography, ultrasound), or provide only limited informatio ...
STTR Phase I 2016 Department of DefenseDefense Logistics Agency -
Detecting Substandard, Nonconforming, Improperly Processed and Counterfeit Materiel
SBC: VIBRANT CORP Topic: DLA15C001Vibrant Corporation and Sandia National Laboratories (SNL) propose to apply Process Compensated Resonance Testing (PCRT) to the DLA's need for an NDI method to detect counterfeit, nonconforming and improperly processed materiel. PCRT collects and analyzes the resonance frequencies of a component to detect structural defects, characterize material, analyze population variation, monitor manufacturin ...
STTR Phase I 2016 Department of DefenseDefense Logistics Agency -
High Gain, High Power PCSS with Integrated Monolithic Optical Trigger
SBC: Eureka Aerospace Topic: A14AT004This proposal addresses the problem of PCSS/laser trigger integration using a single monolithic laser diode array, thus simplifying the entire optical delivery network necessary for efficient operation of PCSSs. The proposal constitutes a logical continuation of Phase I effort where the main focus was on the detailed design of the PCSS/laser diode array (LDA) integrated architecture. In Phase II ...
STTR Phase II 2016 Department of DefenseArmy -
Tunable High-Power Infrared Lasers for Standoff Detection Applications
SBC: EOS Photonics Topic: A14AT015To achieve the goals of this program improving spectral coverage and output power of monolithic QCL sources - we propose to develop in collaboration with MIT Lincoln Laboratory a broadly tunable high power source that is based on Eos proprietary QCL array technology. The current generation of Eos commercially available fully packaged QCLAs (The Matchbox) can be tuned over a wavelength range of u ...
STTR Phase II 2016 Department of DefenseArmy -
Conductive Transmissive Coating for Enhanced-Absorption Thin Film Solar Cells
SBC: AGILTRON, INC. Topic: A15AT016Thin-film, lightweight, large-area flexible inorganic solar cells have shown promise to meet the militarys remote power needs on the battlefield. However, thin film solar cells normally have inferior conversion efficiencies due to limited absorption of sunlight by the thin active layer. Various approaches have been investigated to improve conversion efficiencies of thin film solar cells. Among the ...
STTR Phase I 2016 Department of DefenseArmy