You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. Development of Zeteo Toxic Agent Detection System (zTADS)

    SBC: Zeteo Tech, Inc.            Topic: CBD14101

    The development of the Zeteo Toxic Agent Detection System (zTADS) is presented here. The system features a multiplexed disposable sample collection and processing system that feeds a handheld biological mass spectrometer.

    SBIR Phase I 2014 Department of DefenseOffice for Chemical and Biological Defense
  2. High-affinity monoclonal antibodies that target Burkholderia Polysaccharide

    SBC: DXDISCOVERY INC            Topic: CBD14105

    Melioidosis and glanders are life-threatening illnesses caused by the bacteria Burkholderia pseudomallei and Burkholderia mallei, respectively. These gram-negative bacilli are endemic to Northern Australia and Southeast Asia, however endemic regions are expanding as surveillance improves. B. pseudomallei and B. mallei are classified as Tier 1 select agents for potential use in bioterrorism, largel ...

    SBIR Phase I 2014 Department of DefenseOffice for Chemical and Biological Defense
  3. Respiratory Function Measurement System

    SBC: Physical Optics Corporation            Topic: CBD07112

    To address the CBD need for a real-time measurement system for nonhuman primate tidal volumes, suitable for a Class 3 biological safety (BSL-3) cabinet, Physical Optics Corporation (POC) proposes to develop a new Respiratory Function Measurement (RFM) system. This system is based on a piezoelectric strain transducer that responds to movement of an animal’s thoracic cage during respiration. The ...

    SBIR Phase II 2008 Department of DefenseOffice for Chemical and Biological Defense
  4. Handheld IR Raman Spectroscopy for Rapid Chemical Identification

    SBC: Aerius Photonics, LLC.            Topic: CBD08102

    Aerius Photonics and partner Ahura Scientific, propose to develop a handheld system, based on Ahura’s successful FirstDefender Raman system, that employs an excitation laser emitting at 980 nm and a low noise InGaAs array based on Aerius’ high performance InGaAs technology. This system will substantially reduce the fluorescence present in CCD-based systems, and unmask otherwise obscured spect ...

    SBIR Phase I 2008 Department of DefenseOffice for Chemical and Biological Defense
  5. Dynamic Multicomponent Optical Analyzer for Chemical Weapon (CW) Exposure Studies

    SBC: SCIENCE & ENGINEERING SERVICES, INC.            Topic: CBD08104

    We propose to build a compact laser photoacoustic spectrometric (LPAS) sensor for continuous, real-time broadband analysis of multiple chemical components, and perform field tests to qualify it for dynamic monitoring of chemical warfare agents (CWA). Our sensor will be based on our laboratory LPAS instrument (at technology readiness level TRL-4) that has already demonstrated successful multicompon ...

    SBIR Phase I 2008 Department of DefenseOffice for Chemical and Biological Defense
  6. Dynamic Multicomponent Optical Analyzer for Chemical Weapon (CW) Exposure Studies

    SBC: Los Gatos Research            Topic: CBD08104

    In this SBIR Phase I effort, Los Gatos Research (LGR) proposes to design, develop and test a novel laser-based gas analyzer optimized for chemical weapon exposure studies based on cavity enhanced absorption in the mid-infrared spectral region. This analyzer will provide sensitive and accurate quantification of several chemical weapons through real-time measurements of high-resolution absorption s ...

    SBIR Phase I 2008 Department of DefenseOffice for Chemical and Biological Defense
  7. Combined Dielectrophoretic Microfluidic System

    SBC: Physical Optics Corporation            Topic: CBD08101

    To address the U.S. Army CBD need for a high resolution system whereby proteins present in a complex mixture can be rapidly and reproducibly separated, Physical Optics Corporation (POC) proposes to develop a new Combined Dielectrophoretic Microfluidic (CDM) System based on the integration of electrodeless dielectrophoresis and dynamic isoelectric focusing techniques, used to carry out two-dimensio ...

    SBIR Phase I 2008 Department of DefenseOffice for Chemical and Biological Defense
  8. Botulinum Toxin Plantibodies

    SBC: Planet Biotechnology Incorporated            Topic: CBD03103

    The primary goals of this Phase II application are to successfully manufacture pilot-scale quantities of neutralizing anti-botulinum toxin antibodies in plants, and to complete preclinical studies with these antibodies. Our collaborator, Dr. James D. Mar

    SBIR Phase II 2004 Department of DefenseOffice for Chemical and Biological Defense
  9. Carbon Based Nano-Additives for Chemically and Biologically Protective Polymeric Nanocomposites

    SBC: ATS-MER, LLC            Topic: CBD03304

    The development of carbon-based nano-additive bound polymers with enhanced adsorption capacity and reactivity for the neutralization of chemical and biological warfare agents could cause substantial saving of life during CBWA threats. In the Phase I pr

    SBIR Phase II 2004 Department of DefenseOffice for Chemical and Biological Defense
  10. Integrated Microfiltration Filter and Pump for Portable Water Decontamination System

    SBC: Los Gatos Research            Topic: CBD04304

    Light-weight, high-performance subcomponents, particularly filters and pumps, are needed to make a portable water purifier that can produce clean water from any source. At present, some of the principal problems that hamper this effort include the heavy weight of the pumps and their motors and the large size and fouling rate of pre-treatment filters. These problems may be overcome using Los Gato ...

    SBIR Phase I 2004 Department of DefenseOffice for Chemical and Biological Defense
US Flag An Official Website of the United States Government