You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY23 is not expected to be complete until September, 2024.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. Planar, High Frequency, Power Conversion Device Technology

    SBC: TRANSPHORM, INC.            Topic: N09T023

    Transphorm proposes to demonstrate a normally off fast high voltage Gallium Nitride power switch solution. The switch would block to 1200V, have a threshold voltage greater than 5 V, and the phase 2 switch will target an on resistance less than 15 ohm-mm and current more than 1 Amp. To accomplish these targets, Transphorm will combine the design requirements of realizing a high (and positive) thre ...

    STTR Phase II 2010 Department of DefenseNavy
  2. Frequency agile THz detectors for multiplicative mixing

    SBC: Tanner Research, Inc.            Topic: AF08BT26

    ABSTRACT: A system that operates at room temperature and that could scan for concealed weapons from standoff distances of >10 m would be a tremendous asset for US military homeland security personnel worldwide. THz imaging can, potentially, be used for this application, but it requires the development of a new class of THz detectors whereby the signal to noise ratios are improved significantly. ...

    STTR Phase II 2010 Department of DefenseAir Force
  3. Acoustic Intercept Receiver for Naval Special Warfare Undersea Vehicles

    SBC: Information Systems Laboratories, Inc.            Topic: N09T012

    Information Systems Laboratories (ISL) and Florida Atlantic University (FAU) propose to develop and test a system that uses existing signal processing algorithms coupled with innovative construction technology developed ISL under our E-Field sensor programs and FAU under UUV programs. The Challenge is to develop a small system package with the capability to intercept active threat emissions early ...

    STTR Phase II 2010 Department of DefenseNavy
  4. Passive Infrared Detection of Aerosolized Bacterial Spores

    SBC: DECIBEL RESEARCH, INC.            Topic: A10AT019

    deciBel Research and our university partner, Rochester Institute of Technology (RIT)-Center for Imaging Science, propose to develop a dual MWIR/LWIR imaging polarimeter for the detection and discrimination of aerosolized biological spores. The system will exploit spectral absorption and MIE scattering-induced radiometric and polarimetric phenomenon exhibited by clouds of aerosolized biological spo ...

    STTR Phase I 2010 Department of DefenseArmy
  5. Topological Data Analysis and Wide Area Detection of Chemical and Biological Contamination

    SBC: FOLDED STRUCTURES COMPANY LLC            Topic: A10AT020

    Topological data analysis is a new mathematical method used to study these massive data sets that arise in a variety of situations including military operations and national security. The use of passive infrared sensors for a wide area detection system involving chemical and biological contaminants produces massive amounts of hyperspectral image data. Recent research in this area include fast al ...

    STTR Phase I 2010 Department of DefenseArmy
  6. An Automated, High Throughput, Filter-Free Pathogen Preconcentrator

    SBC: CFD RESEARCH CORPORATION            Topic: A10AT016

    Accurate real-time waterborne pathogen detection is of paramount importance to security of U.S. military forces and installations. Fieldable high-throughput pathogen concentration is a critical analytical need for enhanced detection performance. Existing concentration methods are time-consuming, bulky, labor-intensive, power- and reagent-hungry, and consequently ill-suited for battlefield deployme ...

    STTR Phase I 2010 Department of DefenseArmy
  7. MEMS based thermopile infrared detector array for chemical and biological sensing

    SBC: BFE Acquisition Sub II, LLC            Topic: A10AT004

    Thermopile arrays manufactured using integrated process compatible materials and micro-machining will provide high performance with low manufacturing cost. Black Forest Engineering (BFE) teamed with Case Western Reserve University will design thermopiles using silicon based semiconductors and compare performance. Low cost thermopiles, differentially coupled with advanced BFE CMOS readout, will pr ...

    STTR Phase I 2010 Department of DefenseArmy
  8. Coupled Viscous Vortex Particle Method and Unstructured CFD Solver for Rotorcraft Aerodynamic Interaction Modeling

    SBC: ADVANCED ROTORCRAFT TECHNOLOGY, INC.            Topic: N09T009

    The rotorcraft aerodynamic interaction is a complicated problem and remains an extremely challenging aspect of rotorcraft analysis. This STTR is dedicated to developing a solution for the complicated rotorcraft aerodynamic interaction problem. The Phase I research coupled a state-of-the-art vortex particle method (VPM) with an unstructured Navier-Stokes CFD body surface solver and prototyped a hyb ...

    STTR Phase II 2010 Department of DefenseNavy
  9. Broadband agile wavelength laser for chemical aerosol detection

    SBC: DBC Technology Corp.            Topic: A09AT020

    The Phase I effort was successful in experimentally showing feasibility of a combined isotope transmitter that can be developed and demonstrated under the Phase II program. The initial experimental results give the window of gas mixtures for a stable discharge. Laser extraction tests were accomplished with C12/C13 mixtures to give guidance for further work to increase laser gain. For application ...

    STTR Phase II 2010 Department of DefenseArmy
  10. Large Area IR Metamaterial Films

    SBC: Sensormetrix, INC            Topic: N09T018

    We are proposing to develop a process for large area fabrication of metamaterial films with electromagnetic responses that can be manipulated in the infrared region to enable tailored reflectivity and emissivity. Because the approach is based on metamaterials, this technique can readily be scaled to higher or lower frequencies.

    STTR Phase II 2010 Department of DefenseNavy
US Flag An Official Website of the United States Government