  1. Miniature Residual Life Indicator

    SBC: Physical Optics Corporation            Topic: CBD10106

    Impregnated ASZM-TEDA carbon employed as highly adsorptive materials in Collective Protection (ColPro) systems loses the ability to adsorb toxic chemicals because of exposure to temperature, humidity, battlefield contaminants, and other pollutants. To address the Chemical and Biological Defense (CBD) need for a residual life indicator (RLI) capable of probing the degradation in physical adsorption ...

    SBIR Phase I 2010 Department of DefenseOffice for Chemical and Biological Defense
  2. High Speed Combatant Craft Automated Ride Control

    SBC: CONTINENTAL CONTROLS AND DESIGN, INC.            Topic: SOCOM10005

    We propose to demonstrate an integrated ride control system for high speed small craft. Our approach uses a smart EM actuator and transom trim tabs as a direct replacement for the ubiquitous electrohydraulic and electric systems currently used for static trim adjustments. Our recent IRAD efforts have produced a self contained control system which can be installed on virtually any craft within a f ...

    SBIR Phase I 2010 Department of DefenseSpecial Operations Command
  3. High Speed Combatant Craft Automated Ride Control

    SBC: NAIAD DYNAMICS US INC            Topic: SOCOM10005

    The development of an automated ride control system for high speed combatant craft is critical to reducing the motions that cause injury to crew and damage to craft and equipment. Ancillary benefits include reduced fuel consumption for improved range of operation and the reduction of wake signature. The objective of this research project is to continue the successful development of ride control ...

    SBIR Phase I 2010 Department of DefenseSpecial Operations Command
  4. Optical Wave Guide Integrated Weather Sensor

    SBC: Physical Optics Corporation            Topic: SOCOM10006

    To address the SOCOM need for live, day-and-night weather monitoring, Physical Optics Corporation (POC) proposes to develop a new Optical-Wave-Guide–Integrated Weather Sensor (WAGIS). This proposed device is based on a new design that utilizes in-house–developed mature components and COTS components. The innovation in multispectral optical train design and implementation of POC’s proprietary ...

    SBIR Phase I 2010 Department of DefenseSpecial Operations Command
  5. Next Generation Integrated Electrophoretic Nanofluidic Biochip Sensor Platform for the THz Spectroscopic Finger Printing of Biological Species and Age

    SBC: REDONDO OPTICS, INC.            Topic: CBD10110

    Redondo Optics Inc. (ROI), a world leader in engineering and manufacturing of leading-edge nano-materials, optical sensors, fiber and integrated optics, and advanced photonics instrumentation proposes to develop and demonstrate an integrated electrophoretic nanofluidic biochip sensor platform for the accurate, reliable, and fast-throughput “label-less” THz spectroscopy finger printing of biolo ...

    SBIR Phase I 2010 Department of DefenseOffice for Chemical and Biological Defense
  6. Microfluidic Dielectrophoretic Screening System

    SBC: Physical Optics Corporation            Topic: CBD10107

    To address the U.S. Army/DTRA’s CBD program need for a robust screening process for use with large panels of enzymes to identify variants with higher affinity for organophosphorus (OP) substrates, Physical Optics Corporation (POC) proposes to develop a Microfluidic Dielectrophoretic Screening (MDS) system. This proposed system is based on the new design of a microfluidic mixer, enzymatic reactor ...

    SBIR Phase I 2010 Department of DefenseOffice for Chemical and Biological Defense
  7. A Novel Microfludic Device for Drug Toxicity Studies

    SBC: CFD RESEARCH CORPORATION            Topic: CBD10103

    Current drug discovery and development programs are severely limited by the expensive animal trials and oversimplified in vitro models. Results obtained from the in vitro models are not predictive of in vivo toxicity owing to significant difference in testing from the in vivo physiological conditions. In this context, we propose to develop and demonstrate a novel microfluidic device for quantitati ...

    SBIR Phase I 2010 Department of DefenseOffice for Chemical and Biological Defense
  8. In vitro Models Suitable for High-throughput Screening of Drug Toxicities in Human Tissues

    SBC: Nico Technologies Corp.            Topic: CBD10103

    The drug R&D cycle is long and very expensive. In many ways, this status quo can no longer be sustained. One of the reasons for such great cost is that the vast majority of drug candidates are screened out at the stages of animal and human trials. More efficient methods of testing of drugs at the stage of ex-vivo studies, which are substantially less expensive than animal and human testing cyc ...

    SBIR Phase I 2010 Department of DefenseOffice for Chemical and Biological Defense
  9. Multifunctional Antisense Therapeutics Nanocarrier and Inhalation Device

    SBC: Physical Optics Corporation            Topic: CBD10102

    To address the CBD need for improved formulations to enhance the ease of use and bioavailability of antisense therapeutics, Physical Optics Corporation (POC) proposes to develop a Multifunctional Antisense Therapeutics Nanocarrier and Inhalation Device (MATEN). This proposed system is based on a new dry powder formulation and a novel design of an inhaler that uses in-house developed mature compone ...

    SBIR Phase I 2010 Department of DefenseOffice for Chemical and Biological Defense
  10. 3D Microfluidic Platform for in vitro Hematopoietic Stem Cell (HSC) Culture

    SBC: Physical Optics Corporation            Topic: CBD10103

    To address the Chemical/Bio Defense (CBD) need for in vitro models suitable for high-throughput screening of drug toxicities in human tissues, Physical Optics Corporation (POC) proposes to develop a new three-dimensional (3D) Microfluidic Platform for in-vitro Hematopoietic Stem Cell (HSC) Culture (3D-Mic-Stem). This proposed system is based on a 3D microfluidic design that uses HSCs for assaying ...

    SBIR Phase I 2010 Department of DefenseOffice for Chemical and Biological Defense