A Full Rotation Specimen Holder for State-of-the-art Tomography in a Transmission Electron Microscope
SBC: Hummingbird Precision Machine Co. Topic: 23Three-dimensional electron tomography can render images of the internal structure of solid-state and biological materials at the nanometer scale, and is finding increased application in nanotechnology, semiconductor industries, and the life sciences. However, current systems cannot acquire all the information necessary to construct an optimal tomogram. A major limitation is that these systems do ...
SBIR Phase II 2006 Department of Energy -
Development of a Thermally Stable and Vibration-Free Ultra-High-Temperature Stage for the Transmission Electron Microscope
SBC: Hummingbird Precision Machine Co. Topic: 25Electron microscopes are important tools for materials research. However, the current state of the art for the heating and cooling stages of these microscopes has five major limiting factors: (1) temperature limitation to 1600C, (2) substantial thermal drift, (3) vibration induced from cooling pumps, (4) inadequate temperature control, and (5) lack of reliability. This project will address thes ...
SBIR Phase I 2006 Department of Energy -
System for generation of frozen-hydrated samples using the Focused Ion Beam
SBC: Hummingbird Precision Machine Co. Topic: N/ADESCRIPTION (provided by applicant): The long term objective of our application is to develop hardware and procedures that will allow researchers to better understand the function of the cell. Our specific aim is to provide a system that will allow researchers to better prepare frozen hydrated specimens for study via tomographic reconstruction in the transmission electron microscope(TEM) Current m ...
SBIR Phase I 2006 Department of Health and Human ServicesNational Institutes of Health -
System for generation of frozen-hydrated samples using the Focused Ion Beam
SBC: Hummingbird Precision Machine Co. Topic: N/AProject Summary The long term objective of our application is to develop hardware and procedures that will allow researchers to better understand the function of the cell. Our specific aim is to provide a system that will allow researches to better prepare frozen hydrated specimens for study via tomographic reconstruction in the transmission electron microscope(TEM) Current methods of preparing f ...
SBIR Phase II 2008 Department of Health and Human ServicesNational Institutes of Health -
Instrumentation for Quantifiable Experimental Mechanics at the Deep Nanoscale
SBC: Hummingbird Precision Machine Co. Topic: 01bWith the development of new nanostructured materials, there is an increasing need to quantify their basic properties. The small size scales of the materials complicate the adaptation of existing experimental approaches and require new instruments to perform basic measurements. This project will incorporate a fully-functional scanned-probe system into a sample holder for transmission electron micro ...
SBIR Phase I 2008 Department of Energy -
A Continuous Flow Liquid Cell for the TEM and STEM Microscopes
SBC: Hummingbird Precision Machine Co. Topic: 01bThe addition of continuous fluid flow through a set of electron transparent windows in a transmission electron microscope (TEM) or scanning transmission electron microscope (STEM) will provide the ability to image reactions that occur at the nanoscale. In particular, liquid STEM presents a unique in situ electron microscopy tool to investigate energy conversion at the interface between solid and l ...
SBIR Phase I 2008 Department of Energy -
Phase plate holder for transmission electron microscopy
SBC: Hummingbird Precision Machine Co. Topic: N/ADESCRIPTION (provided by applicant): The objective of our application is to develop hardware and procedures that will allow researchers to practically utilize phase plates in the back focal plane of the objective lens in a Transmission Electron Microscope. Use of precisely positioned phase plates can increase resolution in electron tomography, and also increase throughput when using the single-par ...
SBIR Phase I 2009 Department of Health and Human ServicesNational Institutes of Health -
Supplement for System for generation of frozen-hydrated samples using the Focused
SBC: Hummingbird Precision Machine Co. Topic: N/ADESCRIPTION (provided by applicant): Transmission electron microscope (TEM) tomography provides three-dimensional images at the nanometer scale. It is a mainstream technique in biological electron microscopy, and is rapidly finding applications in the semiconductor and nanotechnology industries. In biology, scientists are interested in producing faithful tomograms of frozen-hydrated samples, since ...
SBIR Phase I 2009 Department of Health and Human ServicesNational Institutes of Health -
Instrumentation for Quantifiable Experimental Mechanics at the Deep Nanoscale
SBC: Hummingbird Precision Machine Co. Topic: N/AResearchers are currently hindered from observing dynamic liquid-liquid and liquid-solid interactions in transmission electron microscopes (TEMs) and scanning transmission electron microscopes (STEMs). Yet, solid-state materials and fluids interact in many important ways. For example, solid-state nanoparticles are formed via solution-based synthesis, and biological cells exist live only in a flu ...
SBIR Phase II 2009 Department of Energy -
An Integrated Environmental Holder for the TEM
SBC: Hummingbird Precision Machine Co. Topic: 05aThe Department of Energy supports the microcharacterization of materials via Transmission Electron Microscopy (TEM) as a core research area. This project will expand the utility of TEM by developing an environmental holder for liquid and gaseous environments. While the proposed effort will focus on gas delivery, existing proven technology will be leveraged for liquid delivery. Thus, the result ...
SBIR Phase I 2009 Department of Energy